Sumry HMS1.5K-12

Contents

HMS 1.5k-12v AC Inverter User Manual

Brand: Sumry | Model: HMS1.5K-12

1. Introduction

This manual provides essential information for the safe and efficient operation of your Sumry HMS 1.5k-12v AC Inverter. This pure sine wave inverter is designed for home solar systems, featuring a built-in MPPT solar charge controller and configurable AC/Solar input priority. Please read this manual thoroughly before installation and use, and keep it for future reference.

2. Key Features

  • Pure sine wave output for sensitive electronics.
  • Integrated MPPT (Maximum Power Point Tracking) solar charge controller for efficient solar energy harvesting.
  • Selectable input voltage range for compatibility with home appliances and personal computers.
  • Adjustable charging current to suit various battery types and applications.
  • Configurable AC/Solar input priority via LCD settings.
  • Compatible with utility mains voltage or generator power.
  • Automatic restart function upon AC recovery.
  • Comprehensive overload and short circuit protection.
  • Smart battery charger design for optimized battery performance and longevity.
  • Parallel operation capability with up to 6 units (for 5KVA models, not applicable to 1.5KVA).

The inverter also includes features such as auto restart, overload protection, short circuit protection, smart battery charger, and pure sine wave output, as illustrated below:

Diagram illustrating key features of the Sumry HMS 1.5k-12v AC Inverter, including utility grid compatibility, home appliance support, MPPT solar charge controller, solar and AC input settings, auto restart, overload protection, short circuit protection, smart battery charger, and pure sine wave output.
Figure 2.1: Inverter Features Overview

3. Product Overview

The Sumry HMS 1.5k-12v AC Inverter is a compact and robust unit designed for efficient power conversion. Below are diagrams illustrating its physical appearance, components, and LCD display.

3.1 Physical Appearance and Dimensions

Front view of the Sumry HMS 1.5k-12v AC Inverter, showing the blue and black casing with an LCD screen and control buttons.
Figure 3.1: Front View of the Inverter
Side view of the Sumry HMS 1.5k-12v AC Inverter.
Figure 3.2: Side View of the Inverter
Diagram showing the dimensions of the Sumry HMS 1.5k-12v AC Inverter: 305mm height, 272mm width, and 100mm depth.
Figure 3.3: Inverter Dimensions (305x272x100mm)

3.2 Inverter Components and Ports

Labeled diagram of the Sumry HMS 1.5k-12v AC Inverter's components and connection ports. Labels include Charging indicator, LCD display, Fault indicator, Function buttons, Status indicator, AC output, AC input, Battery negative, Battery positive, Input breaker, Safety (earth) ground, ON/OFF switch, COM port, and PV input.
Figure 3.4: Inverter Components and Ports
  1. Charging indicator
  2. LCD display
  3. Fault indicator
  4. Function buttons (ESC, UP, DOWN, ENTER)
  5. Status indicator
  6. AC output terminals
  7. AC input terminals
  8. Battery negative terminal
  9. Battery positive terminal
  10. Input breaker
  11. Safety (earth) ground terminal
  12. ON/OFF switch
  13. COM port
  14. PV input terminals

3.3 LCD Display Indicators

Detailed diagram of the LCD display on the Sumry HMS 1.5k-12v AC Inverter, showing various icons and numerical readouts. Each element is numbered and described in a legend.
Figure 3.5: LCD Display and Indicators
  1. PV input indicator
  2. AC input indicator
  3. Input voltage, input frequency, PV voltage, battery voltage, charger current display
  4. Setting programs indicator
  5. Flashing with warning code / Lighting with fault code indicator
  6. Output voltage, output frequency, load percent, load in VA, load in watt, and discharging current display
  7. Load level indicator (0-100%)
  8. DC/AC inverter circuit is working indicator
  9. Battery level indicator
  10. Utility charger circuit is working indicator
  11. Unit connects to the PV panel indicator
  12. Unit connects to the mains indicator
  13. Load is supplied by utility power (Bypass) indicator
  14. Unit alarm is disabled indicator
  15. Overload indicator

3.4 Product Video

Video 3.1: Product showcase of the Sumry HMS 1.5k-12v AC Inverter, highlighting its design and features.

4. Specifications

CategoryParameterValue
GeneralModel No.MPS1.5K-12
Rated Power1500VA/1200W
InputVoltage230VAC
Selectable Voltage Range170-280VAC (for personal computers)
90-280VAC (for home appliances)
Frequency Range50Hz/60Hz (auto sensing)
OutputAC Voltage Regulation (Battery mode)230VAC±5%
Surge Power3000VA
Efficiency (Peak)90-93%
Transfer Time10ms (for personal computers)
20ms (for home appliances)
WaveformPure Sine Wave
Battery & AC ChargerBattery Voltage12VDC
Floating Charge Voltage13.5VDC
Overcharge Protection15.5VDC
Maximum Charge Current10A/20A
Solar ChargerMax PV Array Power500W
MPPT Range @ Operating Voltage15-80VDC
Maximum PV Array Open Circuit Voltage102VDC
Maximum Charging Current60A
Maximum Efficiency98%
Power ConsumptionStandby Power Consumption2W
PhysicalDimension (D*W*H)305*272*100mm
Net Weight5.2kg
ColorBlue
EnvironmentHumidity5%-95% relative humidity (non-condensing)
Operating Temperature0℃ to 55℃
Storage Temperature-15℃ to 60℃
CertificationsCertificateCE
WarrantyWarranty Period1 year

5. Installation and Setup

Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.

5.1 System Connection Diagram

The inverter can be integrated into a hybrid solar system, connecting solar modules, battery packs, the utility grid, and home appliances. Ensure all connections are secure and correctly polarized.

Diagram illustrating a hybrid solar inverter system connection. It shows solar modules connected to the inverter, battery packs connected to the inverter, the utility grid connected to the inverter, and home appliances powered by the inverter.
Figure 5.1: Hybrid Solar Inverter System Connection

5.2 Mounting the Inverter

  1. Choose a suitable location: The inverter should be mounted indoors, in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
  2. Ensure adequate clearance: Leave sufficient space around the inverter for proper airflow and heat dissipation.
  3. Secure mounting: Use appropriate screws and anchors to securely mount the inverter to a sturdy wall or surface. Refer to the mounting brackets on the top of the unit.

5.3 Wiring Connections

Safety Precaution: All wiring should be performed by qualified personnel in accordance with local electrical codes. Ensure all power sources are disconnected before making any connections.

  1. Battery Connection: Connect the battery positive and negative terminals (8 & 9 in Figure 3.4) to your battery bank. Ensure correct polarity.
  2. PV Input Connection: Connect your solar modules to the PV input terminals (14 in Figure 3.4). Observe correct polarity and ensure the PV array voltage is within the specified MPPT range.
  3. AC Input Connection: Connect the utility grid or generator AC power to the AC input terminals (7 in Figure 3.4).
  4. AC Output Connection: Connect your home appliances or load to the AC output terminals (6 in Figure 3.4).
  5. Grounding: Connect the safety (earth) ground terminal (11 in Figure 3.4) to a reliable earth ground.

6. Operation

Once the inverter is properly installed and wired, you can begin operation.

6.1 Powering On/Off

  1. To Power On: Ensure all connections are secure. Turn on the input breaker (10 in Figure 3.4), then switch the ON/OFF button (12 in Figure 3.4) to the 'ON' position. The LCD display will light up, and the inverter will initiate its startup sequence.
  2. To Power Off: First, disconnect the AC output load. Then, switch the ON/OFF button (12 in Figure 3.4) to the 'OFF' position. Finally, turn off the input breaker (10 in Figure 3.4) and disconnect any other power sources.

6.2 LCD Settings and Configuration

The LCD display (2 in Figure 3.4) and function buttons (4 in Figure 3.4) allow you to monitor the system status and configure various parameters, including AC/Solar input priority.

  1. Navigation: Use the 'UP' and 'DOWN' buttons to scroll through different display screens and menu options.
  2. Entering Settings: Press the 'ENTER' button to access a setting menu or confirm a selection.
  3. Exiting Settings: Press the 'ESC' button to exit a menu or return to the previous screen.
  4. Configuring AC/Solar Input Priority: Navigate to the input priority setting (indicated by 4 on the LCD display diagram, Figure 3.5). You can typically choose between 'Solar First', 'Utility First', or 'SBU' (Solar-Battery-Utility) modes. Select the desired priority based on your energy management needs.

Refer to the LCD Display Indicators (Figure 3.5) for detailed information on what each icon and numerical value represents during operation.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connection Checks: Annually, inspect all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
  • Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal cleanliness regularly. Follow battery manufacturer's maintenance guidelines.
  • Environmental Check: Ensure the installation environment remains within the specified temperature and humidity ranges.

8. Troubleshooting

This section provides solutions to common issues you might encounter.

8.1 Common Issues and Solutions

ProblemPossible CauseSolution
Inverter does not turn onNo battery power; DC breaker off; Loose battery connectionCheck battery voltage; Turn on DC breaker; Secure battery terminals
No AC outputOverload; Short circuit; Inverter faultReduce load; Check for short circuits in wiring; Restart inverter
Low battery alarmBattery voltage too lowCharge batteries (via solar or AC input); Reduce load
Overload warning/faultConnected load exceeds inverter capacityDisconnect excess load; Restart inverter
PV input not chargingInsufficient sunlight; PV array disconnected; PV voltage too low/highCheck sunlight conditions; Verify PV connections; Ensure PV voltage is within MPPT range

If the problem persists after attempting these solutions, please contact customer support.

9. User Tips

  • Optimize Solar Input: Ensure your solar panels are clean and optimally angled towards the sun for maximum energy harvest.
  • Load Management: Be mindful of the total power consumption of your appliances to avoid overloading the inverter. Prioritize essential loads during periods of low solar generation or battery charge.
  • Battery Health: Regularly monitor your battery's state of charge and avoid deep discharges to prolong its lifespan.
  • Firmware Updates: Check the manufacturer's website periodically for any available firmware updates that might improve performance or add new features.

10. Warranty and Support

The Sumry HMS 1.5k-12v AC Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.

For technical support, troubleshooting assistance beyond this manual, or warranty inquiries, please contact your retailer or the manufacturer's customer service. Contact details may be found on the product packaging or the official Sumry website.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.