1. Introduction
This manual provides essential information for the safe and efficient operation of your Sumry HMS 1.5k-12v AC Inverter. This pure sine wave inverter is designed for home solar systems, featuring a built-in MPPT solar charge controller and configurable AC/Solar input priority. Please read this manual thoroughly before installation and use, and keep it for future reference.
2. Key Features
- Pure sine wave output for sensitive electronics.
- Integrated MPPT (Maximum Power Point Tracking) solar charge controller for efficient solar energy harvesting.
- Selectable input voltage range for compatibility with home appliances and personal computers.
- Adjustable charging current to suit various battery types and applications.
- Configurable AC/Solar input priority via LCD settings.
- Compatible with utility mains voltage or generator power.
- Automatic restart function upon AC recovery.
- Comprehensive overload and short circuit protection.
- Smart battery charger design for optimized battery performance and longevity.
- Parallel operation capability with up to 6 units (for 5KVA models, not applicable to 1.5KVA).
The inverter also includes features such as auto restart, overload protection, short circuit protection, smart battery charger, and pure sine wave output, as illustrated below:

3. Product Overview
The Sumry HMS 1.5k-12v AC Inverter is a compact and robust unit designed for efficient power conversion. Below are diagrams illustrating its physical appearance, components, and LCD display.
3.1 Physical Appearance and Dimensions



3.2 Inverter Components and Ports

- Charging indicator
- LCD display
- Fault indicator
- Function buttons (ESC, UP, DOWN, ENTER)
- Status indicator
- AC output terminals
- AC input terminals
- Battery negative terminal
- Battery positive terminal
- Input breaker
- Safety (earth) ground terminal
- ON/OFF switch
- COM port
- PV input terminals
3.3 LCD Display Indicators

- PV input indicator
- AC input indicator
- Input voltage, input frequency, PV voltage, battery voltage, charger current display
- Setting programs indicator
- Flashing with warning code / Lighting with fault code indicator
- Output voltage, output frequency, load percent, load in VA, load in watt, and discharging current display
- Load level indicator (0-100%)
- DC/AC inverter circuit is working indicator
- Battery level indicator
- Utility charger circuit is working indicator
- Unit connects to the PV panel indicator
- Unit connects to the mains indicator
- Load is supplied by utility power (Bypass) indicator
- Unit alarm is disabled indicator
- Overload indicator
3.4 Product Video
4. Specifications
| Category | Parameter | Value |
|---|---|---|
| General | Model No. | MPS1.5K-12 |
| Rated Power | 1500VA/1200W | |
| Input | Voltage | 230VAC |
| Selectable Voltage Range | 170-280VAC (for personal computers) 90-280VAC (for home appliances) | |
| Frequency Range | 50Hz/60Hz (auto sensing) | |
| Output | AC Voltage Regulation (Battery mode) | 230VAC±5% |
| Surge Power | 3000VA | |
| Efficiency (Peak) | 90-93% | |
| Transfer Time | 10ms (for personal computers) 20ms (for home appliances) | |
| Waveform | Pure Sine Wave | |
| Battery & AC Charger | Battery Voltage | 12VDC |
| Floating Charge Voltage | 13.5VDC | |
| Overcharge Protection | 15.5VDC | |
| Maximum Charge Current | 10A/20A | |
| Solar Charger | Max PV Array Power | 500W |
| MPPT Range @ Operating Voltage | 15-80VDC | |
| Maximum PV Array Open Circuit Voltage | 102VDC | |
| Maximum Charging Current | 60A | |
| Maximum Efficiency | 98% | |
| Power Consumption | Standby Power Consumption | 2W |
| Physical | Dimension (D*W*H) | 305*272*100mm |
| Net Weight | 5.2kg | |
| Color | Blue | |
| Environment | Humidity | 5%-95% relative humidity (non-condensing) |
| Operating Temperature | 0℃ to 55℃ | |
| Storage Temperature | -15℃ to 60℃ | |
| Certifications | Certificate | CE |
| Warranty | Warranty Period | 1 year |
5. Installation and Setup
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.
5.1 System Connection Diagram
The inverter can be integrated into a hybrid solar system, connecting solar modules, battery packs, the utility grid, and home appliances. Ensure all connections are secure and correctly polarized.

5.2 Mounting the Inverter
- Choose a suitable location: The inverter should be mounted indoors, in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
- Ensure adequate clearance: Leave sufficient space around the inverter for proper airflow and heat dissipation.
- Secure mounting: Use appropriate screws and anchors to securely mount the inverter to a sturdy wall or surface. Refer to the mounting brackets on the top of the unit.
5.3 Wiring Connections
Safety Precaution: All wiring should be performed by qualified personnel in accordance with local electrical codes. Ensure all power sources are disconnected before making any connections.
- Battery Connection: Connect the battery positive and negative terminals (8 & 9 in Figure 3.4) to your battery bank. Ensure correct polarity.
- PV Input Connection: Connect your solar modules to the PV input terminals (14 in Figure 3.4). Observe correct polarity and ensure the PV array voltage is within the specified MPPT range.
- AC Input Connection: Connect the utility grid or generator AC power to the AC input terminals (7 in Figure 3.4).
- AC Output Connection: Connect your home appliances or load to the AC output terminals (6 in Figure 3.4).
- Grounding: Connect the safety (earth) ground terminal (11 in Figure 3.4) to a reliable earth ground.
6. Operation
Once the inverter is properly installed and wired, you can begin operation.
6.1 Powering On/Off
- To Power On: Ensure all connections are secure. Turn on the input breaker (10 in Figure 3.4), then switch the ON/OFF button (12 in Figure 3.4) to the 'ON' position. The LCD display will light up, and the inverter will initiate its startup sequence.
- To Power Off: First, disconnect the AC output load. Then, switch the ON/OFF button (12 in Figure 3.4) to the 'OFF' position. Finally, turn off the input breaker (10 in Figure 3.4) and disconnect any other power sources.
6.2 LCD Settings and Configuration
The LCD display (2 in Figure 3.4) and function buttons (4 in Figure 3.4) allow you to monitor the system status and configure various parameters, including AC/Solar input priority.
- Navigation: Use the 'UP' and 'DOWN' buttons to scroll through different display screens and menu options.
- Entering Settings: Press the 'ENTER' button to access a setting menu or confirm a selection.
- Exiting Settings: Press the 'ESC' button to exit a menu or return to the previous screen.
- Configuring AC/Solar Input Priority: Navigate to the input priority setting (indicated by 4 on the LCD display diagram, Figure 3.5). You can typically choose between 'Solar First', 'Utility First', or 'SBU' (Solar-Battery-Utility) modes. Select the desired priority based on your energy management needs.
Refer to the LCD Display Indicators (Figure 3.5) for detailed information on what each icon and numerical value represents during operation.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connection Checks: Annually, inspect all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
- Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal cleanliness regularly. Follow battery manufacturer's maintenance guidelines.
- Environmental Check: Ensure the installation environment remains within the specified temperature and humidity ranges.
8. Troubleshooting
This section provides solutions to common issues you might encounter.
8.1 Common Issues and Solutions
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter does not turn on | No battery power; DC breaker off; Loose battery connection | Check battery voltage; Turn on DC breaker; Secure battery terminals |
| No AC output | Overload; Short circuit; Inverter fault | Reduce load; Check for short circuits in wiring; Restart inverter |
| Low battery alarm | Battery voltage too low | Charge batteries (via solar or AC input); Reduce load |
| Overload warning/fault | Connected load exceeds inverter capacity | Disconnect excess load; Restart inverter |
| PV input not charging | Insufficient sunlight; PV array disconnected; PV voltage too low/high | Check sunlight conditions; Verify PV connections; Ensure PV voltage is within MPPT range |
If the problem persists after attempting these solutions, please contact customer support.
9. User Tips
- Optimize Solar Input: Ensure your solar panels are clean and optimally angled towards the sun for maximum energy harvest.
- Load Management: Be mindful of the total power consumption of your appliances to avoid overloading the inverter. Prioritize essential loads during periods of low solar generation or battery charge.
- Battery Health: Regularly monitor your battery's state of charge and avoid deep discharges to prolong its lifespan.
- Firmware Updates: Check the manufacturer's website periodically for any available firmware updates that might improve performance or add new features.
10. Warranty and Support
The Sumry HMS 1.5k-12v AC Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance beyond this manual, or warranty inquiries, please contact your retailer or the manufacturer's customer service. Contact details may be found on the product packaging or the official Sumry website.