1. Introduction
This manual provides essential information for the safe and efficient operation of your SUMRY NM-ECO-4.2KW PLUS On/Off Grid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.
The NM-ECO-4.2KW PLUS is a pure sine wave solar inverter designed for both on-grid and off-grid applications. It features a built-in 120A MPPT solar charger, supports operation without a battery, and includes Wi-Fi/GPRS connectivity for monitoring via iOS and Android devices. Its robust design includes an anti-dust kit for harsh environments and smart battery charging to optimize battery life.

2. Safety Information
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury:
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly polarized and securely connected.
- Do not operate the inverter if it is damaged or appears to be malfunctioning.
- Keep the inverter away from flammable materials and ensure adequate ventilation.
- Do not attempt to disassemble or repair the inverter yourself. Contact qualified service personnel.
- Always disconnect all power sources (PV, AC, Battery) before performing any maintenance or cleaning.

3. Product Overview
3.1. Components
The SUMRY NM-ECO-4.2KW PLUS inverter integrates a solar charger, inverter, and battery charger functions into a single unit. Key components include:
- LCD Display and Control Buttons
- AC Input/Output Terminals
- PV Input Terminals
- Battery Terminals
- Input Breaker
- Communication Ports (L-LCD, 2-Wifi)

3.2. System Diagram
The inverter can be integrated into a hybrid solar system, connecting solar modules, a generator, the utility grid, and battery packs to power home appliances.

4. Specifications
| Parameter | Value |
|---|---|
| General | |
| Model | VICTOR NM-ECO-4.2KW PLUS |
| Phase | 1-phase |
| Rated Output Power | 4200W/4200VA |
| Operating Temperature Range | -10℃~50℃ |
| Dimensions (D x W x H) | 420 x 350 x 110 mm |
| Net Weight | 8.0 kg |
| Grid-Tie Operation | |
| PV Input (DC) | |
| Maximum PV Input Power | 6200W |
| Nominal DC Voltage / Maximum DC Voltage | 360VDC / 500VDC |
| Start-up Voltage / Initial Feeding Voltage | 60VDC / 90VDC |
| MPPT Voltage Range | 60VDC~450VDC |
| Number of MPPT Trackers / Maximum Input Current | 1 / 18A |
| Grid Output (AC) | |
| Nominal Output Voltage | 200/230/240VAC |
| Output Voltage Range | 195~253VAC |
| Nominal Output Current | 18.2A |
| Power Factor | >0.99 |
| Feed-in Grid Frequency Range | 49~51±1Hz |
| Efficiency | |
| Maximum Conversion Efficiency (Solar/AC) | 98% |
| Off-Grid Operation | |
| Battery Mode Output (AC) | |
| Nominal Output Voltage | 220/230/240VAC |
| Output Waveform | Pure sine wave |
| Efficiency (DC to AC) | 94% |
| Battery & Charger | |
| Nominal DC Voltage | 24VDC |
| Maximum Solar Charging Current (Solar to AC) | 120A |
| Maximum AC Charging Current | 100A |
5. Installation
5.1. Mounting the Inverter
Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for proper airflow. Use appropriate mounting hardware for the inverter's weight (8.0 kg net weight).
5.2. Wiring Connections
All wiring should comply with local electrical codes and regulations. Refer to the system diagram and rear panel labels for correct connections.
- PV Input: Connect solar modules to the "PV IN" terminals. Ensure correct polarity (+ and -) and that the PV input voltage is within the specified range (60-450VDC MPPT range, max 500VDC).
- Battery Connection: Connect the battery bank (24VDC nominal) to the "BATTERY" terminals. Observe correct polarity (+ and -). The inverter supports automatic activation for lithium batteries.
- AC Input (Utility Grid/Generator): Connect the utility grid or a generator to the "AC IN" terminals.
- AC Output (Loads): Connect your home appliances or loads to the "MAIN OUT" and/or "SECOND OUT" terminals.
- Input Breaker: Ensure the input breaker is correctly installed and rated for the system.
- Communication: Connect L-LCD and 2-Wifi modules as needed for monitoring and control.

WARNING: High voltage is present. Ensure all power sources are disconnected before making or breaking any connections.
6. Operation
6.1. Initial Startup
- After all connections are secure, switch on the battery breaker first.
- Then, switch on the PV array breaker (if applicable).
- Finally, switch on the AC input breaker (if applicable).
- The inverter will perform a self-test and the LCD display will illuminate.
6.2. LCD Display and Control
The LCD display provides real-time system status and allows for configuration. Use the control buttons (typically Up, Down, Enter, and Escape) to navigate menus and adjust settings.

LCD Display Indicators:
- 1: PV input: Indicates power coming from solar panels.
- 2: AC input: Indicates power coming from the utility grid or generator.
- 3: INPUTBATTEMP: Displays input voltage, input frequency, PV voltage, battery voltage, and charger current.
- 4: Setting programs: Shows current program settings.
- 5: Flashing with warning code: Indicates a warning or error condition.
- 6: OUTPUTBATTLOAD: Displays output voltage, output frequency, load percentage, load in VA, load in watt, and discharging current.
- 7: Load level: Visual representation of the current load on the inverter.
- 8: DC/AC inverter circuit is working: Indicates the inverter is actively converting DC to AC.
- 9: Battery level: Shows the current charge level of the battery.
- 10: Utility charger circuit is working: Indicates the utility grid is charging the battery.
- 11: Unit connects to the PV panel: Confirms connection to solar panels.
- 12: Unit connects to the mains: Confirms connection to the utility grid.
- 13: BYPASS: Indicates load is supplied by utility power (bypass mode).
- 14: Unit alarm is disabled: Shows if audible alarms are turned off.
- 15: Overload: Indicates an overload condition.
6.3. Wi-Fi & GPRS Monitoring
The inverter supports Wi-Fi and GPRS connectivity for remote monitoring. Download the dedicated app for iOS or Android devices and follow the in-app instructions to connect your inverter.
6.4. One-Key Restoration to Factory Settings
The inverter features a one-key restoration function to revert all settings to their factory defaults. Consult the full manual for the specific procedure, as this may vary.
7. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter:
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but regular checks are still recommended.
- Connections: Annually check all electrical connections for tightness and signs of corrosion.
- Battery Health: Monitor battery voltage and charge cycles via the LCD or monitoring app. Follow battery manufacturer guidelines for maintenance.
- Environment: Ensure the operating environment remains within the specified temperature range (-10℃~50℃) and free from excessive humidity.
8. Troubleshooting
This section covers common issues and their potential solutions. For more complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery power, battery switch off, PV input too low, AC input disconnected. | Check battery connections and charge. Ensure PV and AC inputs are connected and active. |
| No AC output | Overload, short circuit, inverter fault, output breaker tripped. | Reduce load. Check for short circuits. Reset output breaker. Check LCD for error codes. |
| Low battery charge | Insufficient PV input, AC charger disabled, battery fault. | Check PV panel connections and sunlight. Ensure AC charging is enabled. Inspect battery health. |
| LCD shows warning code (Indicator 5 flashing) | Specific system fault or abnormal condition. | Refer to the full manual's error code section for detailed explanations and solutions. |
| Wi-Fi/GPRS connection issues | Network configuration error, weak signal, app issues. | Verify network settings. Ensure strong signal. Reinstall or update the monitoring app. |
9. User Tips
- Remote Monitoring: Utilize the Wi-Fi/GPRS feature with the dedicated app to monitor your system's performance and battery status remotely. This can help in proactive maintenance.
- Battery-Less Operation: The inverter can run without a battery, which is useful for direct solar power to loads during daylight hours or for specific grid-tie applications. Ensure your system configuration supports this mode if you plan to use it.
- Factory Reset: If you encounter persistent configuration issues, the one-key factory reset can be a quick way to revert to default settings, but remember to reconfigure your specific parameters afterward.
10. Warranty and Support
The SUMRY NM-ECO-4.2KW PLUS inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For warranty claims or technical support, please contact your vendor or the manufacturer directly.
When contacting support, please have your model number (NM-ECO-4.2KW PLUS) and purchase details ready. If you have questions regarding the unit's operation or require assistance, do not hesitate to reach out to the support team.
Contact Information (for support inquiries):
- Email: 1920872317@qq.com
- Tel/Wechat: +86-18973565506
- WhatsApp: +86-18973565506, +86-15007353728