1. Product Overview
The MYAMi HFP Series Hybrid Solar Inverter is an advanced integrated machine designed for solar power generation systems. It combines high-frequency and off-grid inverse control capabilities, providing a reliable and efficient solution for converting solar energy into usable electricity. This inverter is suitable for various applications, offering flexibility with both on-grid and off-grid operation modes.
2. Safety Information
Please read all instructions and warnings carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.
- Installation must be performed by qualified personnel.
- Ensure all connections are secure and correctly polarized.
- Do not operate the inverter if it is damaged or appears to be malfunctioning.
- Keep away from water, moisture, and flammable materials.
- The inverter operates at high voltages (above 50Vac or 75Vdc); exercise extreme caution.
- Ensure proper grounding.
3. Installation and Setup
The MYAMi HFP Series Inverter is designed for wall-mounted installation. Follow these steps for proper setup:
3.1 Unpacking and Inspection
- Carefully unpack the inverter and all accessories.
- Inspect the unit for any physical damage during transit. If damage is found, contact your supplier immediately.
- Verify that all components listed in the packing list are present.
3.2 Mounting the Inverter
- Choose a suitable location for installation. The location should be dry, well-ventilated, and protected from direct sunlight, rain, and dust.
- Ensure there is sufficient clearance around the inverter for proper cooling (refer to specifications for dimensions).
- Mark the positions for drilling holes on the wall using the inverter's mounting brackets as a template.
- Drill the holes and insert appropriate wall anchors.
- Securely mount the inverter to the wall using screws.
3.3 Electrical Connections
All electrical connections must comply with local wiring codes and regulations. Ensure all power sources are disconnected before making any connections.
- **PV Input Connection**: Connect the solar panel array to the PV input terminals. Ensure correct polarity and that the PV input voltage and current are within the inverter's specified range.
- **Battery Connection**: Connect the battery bank to the battery terminals. Observe correct polarity. The inverter supports Lead-acid and Lithium batteries, with customizable charging parameters.
- **AC Input Connection (Grid/Generator)**: Connect the AC grid or generator power source to the AC input terminals.
- **AC Output Connection (Load)**: Connect your electrical loads to the AC output terminals.
- **Grounding**: Ensure the inverter is properly grounded to prevent electrical hazards.
- **Communication (Optional)**: Connect RS485 or Mobile APP (WIFI/GPRS monitoring) modules if desired for remote monitoring.
4. Operation
The inverter features an LCD+LED display and control buttons for easy monitoring and configuration.
4.1 Control Panel
The front panel includes:
- **LCD Display**: Shows real-time system status, operational parameters, and error codes.
- **LED Indicators**:
- **AC**: Indicates AC input status.
- **INV**: Indicates inverter operation status.
- **CHG**: Indicates battery charging status.
- **FAULT**: Indicates system fault or error.
- **Control Buttons**:
- **DOWN**: Navigate down through menu options or decrease values.
- **ESC**: Exit current menu or cancel an operation.
- **ENTER**: Confirm selection or enter a menu.
- **UP**: Navigate up through menu options or increase values.
4.2 Initial Power-Up
- After all connections are made and verified, switch on the battery breaker.
- Switch on the PV array breaker.
- Switch on the AC input breaker (if connected to grid/generator).
- The inverter will perform a self-test and then start operation. Monitor the LCD display and LED indicators for status.
4.3 Operating Modes
The inverter supports various operating modes, which can typically be configured via the LCD display and buttons. Common modes include:
- **Utility-Priority Mode**: AC input (grid/generator) is the primary power source for loads. Solar and battery are used when AC input is unavailable.
- **Solar-Priority Mode**: Solar power is the primary source for loads and battery charging. AC input is used as a backup.
- **Battery-Priority Mode**: Battery power is the primary source for loads. Solar charges the battery, and AC input is a backup.
Refer to the on-screen menu for detailed configuration of battery type, charging parameters, and operating modes.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- **Cleaning**: Periodically clean the exterior of the inverter with a dry cloth. Ensure vents are free from dust and debris to maintain proper airflow for the cooling fan.
- **Connection Check**: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
- **Battery Inspection**: If using lead-acid batteries, check electrolyte levels and terminal conditions as per battery manufacturer guidelines.
- **Environmental Check**: Ensure the installation environment remains dry, well-ventilated, and within the specified operating temperature range (-10°C to 50°C).
- **Firmware Updates**: Check with the manufacturer or supplier for any available firmware updates to improve performance or add features.
6. Troubleshooting
This section provides solutions to common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery power; Battery voltage too low; Loose connections. | Check battery connections and voltage; Ensure battery breaker is ON; Charge battery if necessary. |
| No AC output | Overload; Short circuit; Inverter fault; Battery low voltage protection activated. | Reduce load; Check for short circuits; Check fault codes on LCD; Ensure battery voltage is above protection threshold. |
| Battery not charging | PV input too low/disconnected; AC input disconnected; Charging current setting incorrect; Battery fault. | Check PV connections and sunlight; Verify AC input; Adjust charging settings via LCD; Inspect battery. |
| FAULT LED is on | Internal fault; Over-temperature; Overload; Short circuit. | Check LCD for specific error code; Ensure proper ventilation; Reduce load; Check for short circuits. If fault persists, contact support. |
7. Specifications
Below are the detailed specifications for the MYAMi HFP Series Hybrid Solar Inverter. Note that specifications are subject to change without prior notice, and special voltage/power requirements may be customized.
| Model: | HFP Series (e.g., 13212, 18224, 23224, 33224, 43224, 63248, 83248) | ||||||||
| PV Input | |||||||||
| Max PV Input Power | 2000W (for 13212) up to 6000W*2 (for 103248/123248) | ||||||||
| MPPT Tracking Voltage Range | 30Vdc~240Vdc (for 13212) up to 80Vdc~450Vdc (for higher models) | ||||||||
| Rated Voltage | 180Vdc (for 13212) up to 280Vdc (for higher models) | ||||||||
| Max PV Input Voltage voc (at the lowest temperature) | 300Vdc (for 13212) up to 500Vdc (for higher models) | ||||||||
| Max PV Input Current | 15A (for 13212) up to 27A*2 (for 123248) | ||||||||
| MPPT Tracking Channels (Input Routed) | 1 Routed (for lower models), 2 Routed (for higher models) | ||||||||
| Battery & Charging | |||||||||
| Battery Type | Lead-acid Battery/Lithium Battery; Custom Battery (Charging and discharging parameters of different types of batteries can be set through the operation board) | ||||||||
| Rated Battery Voltage | 12Vdc (for 13212), 24Vdc (for mid-range), 48Vdc (for higher models) | ||||||||
| Battery voltage Range | 0.5~15Vdc (default for 12V), 21~30Vdc (default for 24V), 42~60Vdc (default for 48V) | ||||||||
| Max PV Charging Current | 80A (for 13212) up to 200A (for 123248) | ||||||||
| Max AC Charging Current | 50A (for 13212) up to 140A (for 123248) | ||||||||
| Max Charging Current | 80A (for 13212) up to 200A (for 123248) | ||||||||
| On-Grid Operation (AC Output) | |||||||||
| Rated Output Power | 1300W (for 13212) up to 12.3KW (for 123248) | ||||||||
| Rated Output Voltage | 220Vac/230Vac/240Vac | ||||||||
| Grid Voltage Range | 187Vac~264Vac | ||||||||
| Rated Output Frequency | 50Hz/60Hz | ||||||||
| Frequency Range | 47Hz~52Hz(50Hz), 57Hz~62Hz(60Hz) | ||||||||
| Rated Output Current | 5.9A/5.6A/5.4A (for 13212) up to 55.9A/53.5A/51.3A (for 123248) | ||||||||
| Power Factor | >0.98 (Rated Power) | ||||||||
| Off-Grid Operation (AC Input) | |||||||||
| Rated Input voltage | 220V/230V/240V | ||||||||
| Mains input voltage range | 165Vac~280Vac/120Vac~280Vac (Can be set) | ||||||||
| Rated Input Frequency | 50Hz/60Hz | ||||||||
| Input Frequency Range | 45Hz~55Hz(50Hz), 55Hz~65Hz(60Hz) | ||||||||
| Hybrid Operation (AC Output) | |||||||||
| Rated Output Power | 1300W (for 13212) up to 12.3KW (for 123248) | ||||||||
| Rated Voltage Rated | 220Vac/230Vac/240Vac | ||||||||
| Output Current | 5.9A/5.6A/5.4A (for 13212) up to 55.9A/53.5A/51.3A (for 123248) | ||||||||
| Regular Parameters | |||||||||
| Maximum Conversion Efficiency (Battery Discharge) | 94% (peak value) | ||||||||
| MPPT Tracking Efficiency | ≥99.9 | ||||||||
| Transfer Time | 10ms (Typical value) | ||||||||
| Display | LCD+LED | ||||||||
| Cooling Method | Cooling fan in intelligent control | ||||||||
| Communication | RS485/Mobile APP (WIFI Monitoring or GPRS monitoring) (Optional) | ||||||||
| Protection Degree | IP20 | ||||||||
| Installation | Wall-Mounted | ||||||||
| Protection Features | |||||||||
| Battery low voltage alarm | 11Vdc (default value for 12V), 22Vdc (default value for 24V), 44Vdc (default value for 48V) | ||||||||
| Battery low voltage protection | 10.5Vdc (default value for 12V), 21Vdc (default value for 24V), 42Vdc (default value for 48V) | ||||||||
| Anti-islanding protection | ≤2S | ||||||||
| Overload power protection | Automatic Protection (battery mode), Circuit Breaker or Insurance (AC mode) | ||||||||
| Output short circuit protection | Automatic Protection (battery mode), Circuit Breaker or Insurance (AC mode) | ||||||||
| Temperature protection | >90℃ (turn off inverter and charging) | ||||||||
| Environment | |||||||||
| Operating temperature | -10°C~50°C | ||||||||
| Storage temperature | -15°C~60°C | ||||||||
| Noise | ≤55dB | ||||||||
| Elevation | 2000m (More than derating) | ||||||||
| Humidity | 0%~95%, No condensation | ||||||||
| Dimensions And Weight | |||||||||
| Product Size (L*W*Hmm) | 285*250*91 (for 13212) up to 630*540*130 (for 123248) | ||||||||
| Package Size (L*W*Hmm) | 360*305*156 (for 13212) up to 730*635*225 (for 123248) | ||||||||
| Net Weight (kg) | 4 (for 13212) up to 22 (for 123248) | ||||||||
| Gross Weight (kg) | 5 (for 13212) up to 25 (for 123248) | ||||||||
Note: 1.Specifications are subject to change without prior notice; 2.Special voltage and power requirements can be customized according to the actual situation of users.
8. User Tips
- **Battery Compatibility**: Always ensure your battery type and voltage are compatible with the inverter settings. Incorrect settings can damage the battery or inverter.
- **Load Management**: Avoid consistently running the inverter at its maximum rated power. Leave some headroom for optimal efficiency and longevity.
- **Monitoring**: Utilize the optional WIFI or GPRS monitoring features to keep track of your system's performance and health remotely. This can help in early detection of issues.
- **Ventilation**: Ensure the area around the inverter is always clear to allow for proper heat dissipation, especially during high load operation.
- **Professional Installation**: For safety and optimal performance, it is highly recommended to have the inverter installed by a certified electrician or solar professional.
9. Warranty and Support
For warranty information, technical support, or service requests, please contact your point of purchase or the MYAMi Official Store directly. Keep your purchase receipt and product serial number handy when contacting support.
MYAMi Official Store: Visit Store