KONLEN KL-W96L-Tuya

Contents

KONLEN KL-W96L-Tuya Smart Water Level Controller

Model: KL-W96L-Tuya

1. Introduction

The KONLEN WIFI intelligent water level controller is designed for precise water level monitoring and control. It allows users to manage water supplement or drainage, and receive high and low water level alarm notifications directly on their smartphone via a dedicated application.

This product is suitable for a wide range of water level control applications, including HVAC systems, hot water processes, municipal drainage, boilers, water towers, storage tanks, and breeding irrigation systems.

KONLEN Smart Controller with water tank level diagram and smartphone app interface
Figure 1: KONLEN Smart Controller in operation with app interface.
Hexagonal collage showing various applications for the water level controller
Figure 2: Diverse applications of the Smart Water Level Controller.

2. Main Features

  • Real-Time Supervision: The mobile application displays the current water level.
  • Remote Equipment Control: Turn equipment (connected to Relay 1) on/off remotely via the app. A manual switch button (B) is also available on the device.
  • Dual Relay Outputs: Relay 1 controls water level, while Relay 2 provides anti-dry heating protection.
  • Pre-set Working Modes: Configure "Add water" or "Pump water" modes for automatic activation/deactivation of Relay 1 based on pre-set water level values.
  • Customizable Water Level Alarms: Set upper and lower water level limits via the app to receive real-time push notifications on your smartphone.
  • Adjustable Relay Timing: Configure Relay 1's running or delay working time.
Diagram of the KONLEN Smart Controller with labeled buttons and indicators
Figure 3: Front panel of the Smart Controller with key components.

Controller Interface Description:

  • A: Wi-Fi configuration button.
  • B: On/Off Switch for Relay Output 1. This manual switch is effective only when the current water level is between the pre-set start and stop water level values.
  • C: Wi-Fi Configuration Indicator / Relay Output 1 Status Indicator.
  • D: Relay Output 2 Status Indicator.

3. Package Contents

The standard package for the AC220V version includes:

  • 1x KONLEN Wi-Fi Water Level Controller
  • 1x English Instruction Manual
  • 5x Water Level Sensors with varying cable lengths:
    • White cable: 3.5 meters (approx. 11.48 ft)
    • Red cable: 3.1 meters (approx. 10.17 ft)
    • Yellow cable: 2.3 meters (approx. 7.54 ft)
    • Green cable: 1.1 meters (approx. 3.60 ft)
    • Blue cable: 1 meter (approx. 3.28 ft)

Note: Users can extend the sensor cables if needed. The maximum recommended extension length is 50 meters (approx. 165 ft).

KONLEN Smart Controller and five water level sensors
Figure 4: Included components: Controller and water level sensors.

4. Specifications

Feature Detail
Controller Dimensions 89mm x 55mm x 44mm (3.5 x 2.16 x 1.73 inches)
Power Voltage AC220V (range AC210V-240V) as default; DC12V version optional.
Power Consumption Less than 2W
Relay Output 1 Limited Running Time 0 to 720 minutes (settable via App, in 5-minute increments)
Relay Output 1 Time Delay Setting 0 to 30 seconds (settable via App)
Relay Outputs Two (Normal Open)
Contact Current Capacity 10A for resistive load, 2A for inductive load. Controls 2000W resistive load or 500W motor/water pump. Larger loads require AC contactor expansion.
Working Environment -10℃ to +50℃
Wi-Fi Connectivity 2.4GHZ b/g/n (5G Wi-Fi not supported)
Sensor Cable Lengths White: 3.5m, Red: 3.1m, Yellow: 2.3m, Green: 1.1m, Blue: 1m
Max Sensor Cable Extension 50 meters (approx. 165 ft)
Front, side, and back views of the KONLEN Smart Controller with dimensions
Figure 5: Controller dimensions.

5. Installation and Wiring

5.1 Terminal Connections

Refer to the diagram below for proper wiring. Ensure all connections are secure before powering on the device.

  • Terminal 1: Not used.
  • Terminal 2: 100% water level sensor.
  • Terminal 3: 75% water level sensor.
  • Terminal 4: 50% water level sensor.
  • Terminal 5: 25% water level sensor.
  • Terminal 6: Public water point (COM) for sensors.
  • Terminal 7, 8: Relay Output 1 (Normal Open) - typically for water pumps.
  • Terminal 9, 10: Relay Output 2 (Normal Open) - typically for anti-dry heating protection or alarm output.
  • Terminal 11, 12: Power Supply (AC220V or DC12V depending on version).

Important: If your country uses AC90V to AC120V and not AC220V, please ensure you have the DC12V version of the controller. The DC12V version includes a DC12V power adapter with appropriate plug for your region.

5.2 Wiring Connection Example (Add Water Mode)

This example illustrates the wiring for adding water to a tank, including connections for a pump/valve and a heater for anti-dry heating protection.

Wiring diagram for 'Add Water' mode, showing connections for sensors, pump/valve, heater, and power supply
Figure 6: Wiring diagram for 'Add Water' mode.

Water Level Indication:

  • Water level rising: < 25% electrode (App displays 0%); reaches 25% (App displays 25%); reaches 50% (App displays 50%); reaches 100% (App displays 100%).
  • Water level reducing: Below 100% (App displays 75%); below 75% (App displays 50%); below 50% (App displays 25%); below 25% (App displays 0%).

Relay Functionality:

  • Relay Output 1 (Terminals 7, 8): Connects to water pumps for controlling their on/off state.
  • Relay Output 2 (Terminals 9, 10): Used for anti-dry heating protection. In 'Add Water' mode, it can connect to a heater for automatic control. When the water level is < 25%, the heater (Relay Output 2) automatically turns off. When the water level is ≥ 25%, the heater turns on after a 15-second delay.
  • In 'Pump Water' mode, Relay 2 functions solely as an alarm output.

6. App and Wi-Fi Configuration

The controller operates with the Tuya Smart App or Smart Life App.

6.1 App Installation

  1. Download the Tuya Smart App from Google Play (for Android) or the App Store (for iOS).
  2. Install the Tuya Smart App.
  3. Register a new account using your email address.
Screenshots showing Tuya app logo, Cloudy home screen, and Add Device manually option
Figure 7: Tuya Smart App installation and initial setup.

6.2 Adding Device via Wi-Fi Configuration

  1. Log in to your App account.
  2. Follow the in-app instructions to add a new device. You will typically select 'Sensor (Wi-Fi)' from the device list.
  3. Enter your Wi-Fi password. Ensure your Wi-Fi network is 2.4GHz (5GHz networks are not supported).
  4. Place your router, mobile phone, and the device as close as possible during the connection process.
  5. Once connected, the device will appear in your app.
Screenshots showing Wi-Fi password entry, connection progress, and successful device addition in the app
Figure 8: App Wi-Fi configuration steps.

7. Operation Modes

The app interface provides various settings and real-time information for controlling the water level controller.

Smartphone app interface screenshots for 'Add Water Mode' and 'Pump Water Mode' with numbered features
Figure 9: App interface for 'Add Water' and 'Pump Water' modes.
  1. Device Name: Can be modified for easy identification.
  2. On/Off Switch of Relay 1: Manually control Relay 1. This is effective only when the current water level is between the pre-set start and stop levels.
  3. Real-time Water Level Display: Shows current water level (0%, 25%, 50%, 75%, 100%).
  4. Work Mode Selection: Choose between 'Add Water' or 'Pump Water'.
  5. Set Water Level Value for Auto Start/Stop: Define the water levels at which the equipment (connected to Relay 1) should automatically start or stop. For example, in 'Pumping' mode, set 'Level On' to 100% and 'Level Off' to 25% to start pumping at 100% and stop below 25%.
  6. Anti Water Dry Heating Protection: In 'Add Water' mode, this feature automatically turns Relay Output 2 (for heater) off if the water level drops below 25% and turns it back on (with a 15-second delay) if the level is ≥ 25%.
  7. Alarm Enable/Disable: Toggle alarm notifications on or off.
  8. Set Water Level Lower Limit Alarm: Define the minimum water level for an alarm.
  9. Set Water Level Upper Limit Alarm: Define the maximum water level for an alarm.
  10. Set Delay Time of Relay 1 Starting: Configure a delay before Relay 1 activates.
  11. Show Current Sensor Status: Displays the current status of the water level sensors.
  12. Set Limited Running Time of Relay Output 1: Configure a maximum running time for Relay 1.

7.1 Control Mode 1: Add Water

In this mode, the controller maintains the water level by activating a pump/valve when the level drops below a set threshold and deactivating it when the level reaches the desired maximum.

  • If water level ≥ preset "stop level", Relay Output 1 disconnects, stopping water addition.
  • If water level < preset "start up level", Relay Output 1 connects, starting water addition.
  • Anti Water Dry Heating Protection: If water level < 25%, Relay Output 2 disconnects (stops heating). If water level ≥ 25%, Relay Output 2 connects after a 15-second delay (starts heating).
Visual demonstration of 'Add Liquid' mode with a pump and water level changes
Figure 10: 'Add Liquid' operation example.

7.2 Control Mode 2: Pump Water (Draining)

This mode is used for draining water from a tank or pool.

  • If water level < preset "stop level", Relay Output 1 disconnects, stopping water pumping.
  • If water level ≥ preset "start up level", Relay Output 1 connects, starting water pumping.
  • In 'Pump Water' mode, Relay 2 acts as an alarm output. It connects if the water level is ≤ the preset lower limit alarm value or ≥ the upper limit alarm value.
Visual demonstration of 'Draining' mode with a pump and water level changes
Figure 11: 'Draining' operation example.

7.3 Time-Limited Control

The controller supports time-limited operations for both adding and pumping water.

Smartphone app interface screenshot showing 'Work Mode Add Water+Time' and 'Pumping+Time' options, and 'Running Time' setting
Figure 12: Time-limited control settings in the app.

Mode 3: Time-Limited Adding Water

When the water level drops below the "start up level", Relay Output 1 connects to start adding water and simultaneously initiates a timer. Relay 1 will automatically disconnect, stopping water addition, once the pre-set limited running time is reached.

Mode 4: Time-Limited Pumping

When the water level rises to or above the "start up level", Relay Output 1 connects to start pumping water and simultaneously initiates a timer. Relay 1 will automatically disconnect, stopping water pumping, once the pre-set limited running time is reached.

8. Alarm Notifications

The controller can send push notifications to your smartphone when water levels exceed or fall below pre-set limits.

For example, if the preset lower limit is 25% and the upper limit is 75%, an alarm notification will be pushed to your smartphone via the app if the water level drops below 25% or rises above 75%.

Smartphone app screenshots showing 'Lower Limit Alarm' and 'Upper Limited Alarm' notifications
Figure 13: App alarm notifications for water level limits.

9. User Tips

  • For optimal Wi-Fi connectivity during setup, ensure your router, smartphone, and the controller are in close proximity.
  • Always verify that your Wi-Fi network is 2.4GHz, as 5GHz networks are not supported by this device.
  • When extending sensor cables, use appropriate gauge wiring and ensure waterproof connections to maintain accuracy and prevent damage.
  • Regularly check the sensor probes for any buildup or corrosion that might affect their accuracy.

10. Troubleshooting

10.1 Device Not Connecting to Wi-Fi

  • Ensure your Wi-Fi network is 2.4GHz. 5GHz networks are not compatible.
  • Verify that the Wi-Fi password entered in the app is correct.
  • Move the controller closer to your Wi-Fi router during the setup process.
  • Check if your router has too many connected devices, which might prevent new connections.
  • Restart the controller and your router, then try the configuration process again.

10.2 Incorrect Water Level Readings

  • Inspect the water level sensors for any dirt, debris, or corrosion that might be affecting their conductivity. Clean them if necessary.
  • Ensure the sensor cables are properly connected to the correct terminals (25%, 50%, 75%, 100%, COM).
  • Check for any damage to the sensor cables or probes.

10.3 Relay Not Activating/Deactivating

  • Verify that the power supply to the controller is stable and within the specified voltage range (AC210V-240V for AC version, or 12V for DC version).
  • Check the wiring connections for Relay Output 1 and 2 (Terminals 7-10) to ensure they are secure and correctly wired to your pump/heater.
  • Confirm that the 'Work Mode' and 'Start/Stop Level' settings in the app are configured as desired.
  • If controlling a large load, ensure an AC contactor is used as specified in the specifications.

11. Warranty and Support

For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.