1. Introduction
Welcome to the PowMr POW-M80-PRO MPPT Solar Charge Controller. This manual provides essential information for the safe and efficient operation of your solar charge controller. Designed for optimal performance and reliability, this controller features advanced Maximum Power Point Tracking (MPPT) technology to maximize energy harvesting from your solar panels.
The POW-M80-PRO is compatible with 12V, 24V, 36V, and 48V battery banks, supporting various battery types including flooded lead-acid, gel-sealed lead-acid, and lithium batteries. It incorporates multi-stage charging algorithms to extend battery life and includes comprehensive self-diagnostic and electronic protection functions to ensure system reliability and stability. Its parallel operation capability allows for easy expansion of your solar energy system.
For detailed specifications and operational guidelines, please refer to the sections below. For a comprehensive PDF version of this manual, you can view the User Manual (PDF).
Video 1.1: PowMr MPPT Solar Charge Controller Product Overview
2. Important Safety Instructions
WARNING: Carefully read and adhere to all safety instructions.
- Before installing and operating the controller, thoroughly read this user manual and keep it for future reference.
- Installation and operation should only be performed by individuals with proper training and supervision.
- Individuals lacking necessary knowledge, experience, or capabilities, or those with physical, sensory, or intellectual impairments that could affect safe installation and operation, should not perform these tasks.
2.1 Controller Installation and Operation Safety
- This controller has no user-serviceable components; do not disassemble or attempt repairs.
- Install the controller in a well-ventilated area with adequate clearance.
- Mount the controller on non-combustible walls, away from flammable materials. Heat generation during operation is normal.
- Protect the controller from direct sunlight, rain, humidity, and dust. Keep it away from flammable liquids or gases. For indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- Do not place any objects on top of the controller.
2.2 Battery Installation and Charging Safety
- Install and charge batteries in well-ventilated or exhaust-ventilated environments.
- Ensure no open flames are near batteries, as they emit explosive gases.
- Battery acid is corrosive. If contact occurs, rinse immediately with clean water.
- Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
- Ensure the equipment is properly configured for the type of battery connected.
2.3 DC Battery Connections Safety
- Ensure the DC system is fully off/powered down by disconnecting all cables and/or new ports from the battery/DC system.
- Use flexible, multi-strand copper cables with appropriate cross-sectional area, and connect them to matching fuses or circuit breakers.
- Connecting the photovoltaic array to the controller is prohibited until the battery is connected first.
2.4 Controller Configuration Safety
- Refer to the battery manufacturer's guide and specifications for suitability and recommended charging settings.
- Integrated charging modes include adaptive charging logic, suitable for most battery types.
3. Product Appearance
The following diagram illustrates the key components and interfaces of the PowMr MPPT Solar Charge Controller.

Figure 3.1: PowMr MPPT Solar Charge Controller Overview
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | LCD Display Screen | 5 | Temperature Probe Port |
| 2 | Function Keys | 6 | Parallel Communication Port |
| 3 | Photovoltaic Input Interface | 7 | Port Cover Plate |
| 4 | Battery Interface | 8 | Heat Dissipation Vent |
4. Installation and Wiring
4.1 Unpacking and Inspection
Before installation, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. The package should contain:
- Controller
- User Manual
- Installation screws
- Parallel connector
- External temperature sensor
4.2 Choosing the Installation Location
Select a suitable and safe installation location considering the following:
- Install the controller in a space with good natural ventilation/exhaust.
- Avoid direct sunlight.
- Ensure ample clearance around the controller. A minimum clearance of 75mm is recommended at the top, bottom, and both sides.
- Install the controller on a non-combustible wall, away from flammable materials. An increase in temperature during controller operation is normal.
- When running multiple controllers in parallel, install them at the same horizontal height with a minimum spacing of 200mm between controllers.
4.3 Wiring Precautions
- Installation and wiring must be carried out by a certified electrician.
- Wiring should follow the sequence: Battery > PV Input.
- To avoid short-circuits and polarity reversal, ensure the positive (+) cable is connected to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
- Tighten all cables to minimize transition resistance and prevent overheating. Use cable sizes appropriate for the circuit's current rating.
4.4 Installation and Wiring Guidelines
Follow these steps for installation and wiring. For parallel connection wiring, refer to Section 6.
- Step 1. Install the controller: Vertically mount the controller with its ports facing downward, securing it to the wall using the four mounting holes. Use two upper screws for initial "hanging," then add two lower screws, and fully tighten all four.
- Step 2. Battery Wiring: Connect the battery to the controller using appropriate cables.
- All wiring tasks must be performed by professionals.
- For safe operation, install circuit breakers of appropriate specifications on cables connected to the controller and ensure tight connections.
- Ensure all circuit breakers are in the off position before completing wiring.
- Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
- These notes also apply to the PV ports and DC output ports.
- Step 3. PV Wiring: Connect the photovoltaic array to the controller using cables.
- Step 4. Temperature Probe Connection: Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
- Step 5. Pre-Startup Check: Refer to the wiring diagrams. If all connections are accurate and securely connected, close the circuit breakers in the order of Battery and PV Input circuitry.

Figure 4.1: Controller Mounting Diagram

Figure 4.2: Solar Connect Diagram (Battery and PV connections)
ATTENTION:

Figure 4.3: PV Array Connection Diagram

Figure 4.4: Temperature Probe Connection
WARNING: Risk of Electric Shock!
Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.
5. Operation Guide
5.1 Operation Interface Overview
The LCD display screen provides real-time operational data and system status. The main indicators are:

Figure 5.1: LCD Display Screen Indicators
| No. | Function |
|---|---|
| ① | Day/Night Indicator Icon, indicating the presence of photovoltaic input |
| ② | Battery Remaining Capacity Indicator |
| ③ | Charging in Progress Indicator |
| ④ | Photovoltaic Input Voltage/Power/Operating Mode/Fault Codes |
| ⑤ | Current Battery Voltage/Charging Current/Device Temperature/Battery Calibration Voltage/Parallel Communication Code/Battery Type/Boost Charging Voltage/Float Charging Voltage/MPP Tracking Return Voltage |
5.2 Button Functions
The controller features three function keys: PV/SET, BAT/▲, and BAT/▼ for navigation and settings adjustment.

Figure 5.2: Controller Function Keys
| Button | Mode | Description |
|---|---|---|
| PV/SET | Browsing Mode | Switch photovoltaic input parameters |
| Setup Mode | Confirm settings | |
| BAT/▲ | Browsing Mode | Short Press: Switch battery parameters, move to the next item Long Press: Enter battery parameter settings |
| Setup Mode | Increase value/return to the previous item and move to the next | |
| BAT/▼ | Browsing Mode | Switch battery parameters, return to the previous item |
| Setup Mode | Decrease value/return to the previous item Long press to restore factory settings. |
Note: "Setup Mode" for BAT/▲ and BAT/▼ specifically refers to setting battery parameters.
5.3 Overview of Photovoltaic Parameters
A short press of the PV/SET key cycles through the following data on the left side of the display:
- PV Input Voltage
- PV Input Power
- Operating Mode/Fault Codes
Operating Modes:
| Mode Code | Description |
|---|---|
| 3.0 | Night Mode, not charging |
| 4.0 | Fast Charging Mode (MPPT Mode) |
| 7.0 | Boost Charging Mode |
| 8.0 | Float Charging Mode |
Note: In case of a fault, the Operating Mode section will display a fault code. Refer to Section 8. Troubleshooting for details.
5.4 Overview of Battery Parameters
In browsing mode, use the BAT/▲ and BAT/▼ keys to scroll through battery parameters. To adjust a parameter, long-press BAT/▲ to enter setting mode, use BAT/▲ and BAT/▼ to change values, and press PV/SET to confirm.
Parameters include: Current Battery Voltage, Charging Current, Device Temperature, Battery Type, Parallel Communication Code, Calibrated Battery Voltage, Boost Charging Voltage, Float Charging Voltage, and MPP Tracking Return Voltage.
5.5 Battery Parameter Settings
The following battery-related parameters can be configured:
- Calibrated Battery Voltage: Adjust this setting if there's a difference between the controller's monitored battery voltage and a multimeter reading. Long-press BAT/▲, adjust with BAT/▲ and BAT/▼, then press PV/SET to save.
- Parallel Communication Code Setting: In parallel operation, each controller needs a unique communication code (01-06). The controller with the smallest code becomes the host. If the host fails, the system automatically designates the controller with the next code as the new host. This setting is not needed if not operating in parallel.
- Battery Type Setting: Select the battery type from the table below. Long-press BAT/▲, use BAT/▲ and BAT/▼ to toggle options, and press PV/SET to save.
| Order | Display | Battery Type |
|---|---|---|
| 1 | SEL | Sealed Lead-Acid Battery |
| 2 | GEL | Gel Sealed Lead-Acid Battery |
| 3 | FLd | Flooded Lead-Acid Battery |
| 4 | L04 | 4-Series LiFePO4 Battery |
| 5 | L07 | 7-Series LiFePO4 Battery |
| 6 | L08 | 8-Series LiFePO4 Battery |
| 7 | L15 | 15-Series LiFePO4 Battery |
| 8 | L16 | 16-Series LiFePO4 Battery |
| 9 | N03 | 3-Series Lithium-Ion Battery |
| 10 | N06 | 6-Series Lithium-Ion Battery |
| 11 | N07 | 7-Series Lithium-Ion Battery |
| 12 | N13 | 13-Series Lithium-Ion Battery |
| 13 | N14 | 14-Series Lithium-Ion Battery |
| 14 | USE | User-defined |
5.6 Custom Configuration of Charging Voltage
If "USE" (User-defined mode) is selected for battery type, the following five charging parameters can be manually set:
- Nominal System Voltage (12V/24V/36V/48V)
- Boost Charging Voltage (9.0~17.0V)
- Float Charging Voltage (9.0~17.0V)
- MPP Tracking Return Voltage (9.0~17.0V)
Setting Steps:
- Use BAT/▲ and BAT/▼ keys to select the parameter.
- Long-press BAT/▲ to enter the setting mode.
- Use BAT/▲ and BAT/▼ keys to adjust the voltage value.
- Press PV/SET key to confirm and save.
Note: These parameters are for 12V batteries. For 24V/36V/48V systems, the range values are 2/3/4 times the specified range, respectively. The LCD screen only displays 12V values.
Logic for setting custom battery voltage parameters:
Maximum Charging Voltage > Boost Charging Voltage > Float Charging Voltage > MPP Tracking Return Voltage
5.7 Default Parameters for Different Battery Types
The controller has default charging parameters for various battery types. If "USE" mode is not selected, the controller will use these preset values.
For Lead-Acid Batteries and User-defined Batteries:
| Parameters | FLd (Flooded) | GEL (Gel Sealed) | SEL (Sealed) | USE (User-defined) |
|---|---|---|---|---|
| Boost Charging Voltage | 14.6V | 14.2V | 14.4V | 9.0~17.0V |
| Float Charging Voltage | 13.8V | 13.8V | 13.8V | 9.0~17.0V |
| MPP Tracking Return Voltage | 13.2V | 13.2V | 13.2V | 9.0~17.0V |
For Lithium-Ion Batteries:
| Parameters | N03 (3-Series) | N06 (6-Series) | N07 (7-Series) | N13 (13-Series) | N14 (14-Series) |
|---|---|---|---|---|---|
| Boost Charging Voltage | 12.5V | 25.0V | 29.2V | 54.2V | 58.3V |
| Float Charging Voltage | 12.2V | 24.4V | 28.5V | 52.9V | 56.9V |
| MPP Tracking Return Voltage | 11.7V | 23.4V | 27.3V | 50.7V | 54.6V |
For LiFePO4 Batteries:
| Parameters | L04 (4-Series) | L07 (7-Series) | L08 (8-Series) | L15 (15-Series) | L16 (16-Series) |
|---|---|---|---|---|---|
| Boost Charging Voltage | 14.5V | 25.4V | 29.0V | 54.4V | 58.0V |
| Float Charging Voltage | 13.8V | 24.1V | 27.6V | 51.8V | 55.2V |
| MPP Tracking Return Voltage | 13.2V | 23.1V | 26.4V | 49.5V | 52.8V |
6. Parallel Operation Guide
The PowMr MPPT Solar Charge Controller supports parallel operation for expanding your solar energy system. Up to 12 units can be connected in parallel.
6.1 Parallel Operation Schematic

Figure 6.1: Parallel Operation Schematic
6.2 Main Modules in Parallel Operation
- Controller: Designed for both standalone and parallel operation. Communication between controllers is achieved through communication lines. Parallel controllers should be installed at the same horizontal level.
- Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power connected to each controller should not exceed the rated input power of a single controller.
- Battery Bank: Parallel controllers are connected to the same battery bank.
6.3 Parallel Installation and Wiring
- Step 1. Install parallel devices: Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
- Step 2. Connect communication cables.
- Step 3. Connect all parallel controllers to the same battery bank.
- Step 4. Connect each controller to its respective photovoltaic array.
- Step 5. Power on and Configure: After completing the wiring, power on by closing the battery circuit breaker. Once powered on, set the master and slave configurations as defined in Section 5.5. Then, proceed to configure the entire parallel system through the master controller.

Figure 6.2: Parallel Controller Installation
NOTE:
- All wiring tasks must be performed by professionals.
- For safety and compliance, the cables connected to the controller must have corresponding circuit breakers installed, ensuring tight connections.
- Before completing all wiring, ensure that all circuit breakers are in the off position.
- Connect the positive cable terminal to the positive port and the negative cable terminal to the negative port.
7. Maintenance
To ensure optimal performance and longevity of your PowMr MPPT Solar Charge Controller, we recommend conducting the following checks and maintenance at least twice a year:
- Ensure the controller is securely mounted in a clean and dry environment.
- Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
- Inspect all exposed wires for insulation damage (e.g., from sun exposure, friction, dryness, insects, rodents). Repair or replace damaged wires as necessary.
- Tighten all terminals and check for loose, broken, or burnt cable connections.
- Confirm that all system components are properly grounded.
- Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. If present, clean promptly.
WARNING: Risk of electric shock!
Before performing any maintenance operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.
8. Troubleshooting
When a fault occurs, the controller will display a fault code to assist you in finding a solution. Refer to the table below for common fault codes and their solutions.
| Fault Code | Possible Causes | Solutions |
|---|---|---|
| 18 | Low input photovoltaic voltage | Increase the number of solar panels or connect them in series to raise the photovoltaic input voltage. |
| 60 | Overtemperature protection | Allow the device to cool below the recovery temperature to resume normal charging and discharging. |
| 63 | High battery voltage | Measure and confirm if the battery voltage exceeds the rated voltage. If so, close the photovoltaic array circuit breaker. |
| 65 | Low battery voltage | Charge the battery until the voltage exceeds the undervoltage termination voltage. Refer to "5.7 Default Parameters for Different Battery Types" for specific values. |
| 71 | High input photovoltaic voltage | Reduce the number of connected photovoltaic arrays to lower the photovoltaic input. Alternatively, modify the series and parallel connection to decrease voltage or current values. |
| 73 | Overcharging current | Reduce the number of connected photovoltaic arrays to lower the photovoltaic input. Alternatively, modify the series and parallel connection to decrease voltage or current values. |
9. Specifications
Detailed technical specifications for the PowMr POW-M80-PRO MPPT Solar Charge Controller:
| Model | POW-M80-PRO | |
|---|---|---|
| Solar Input Specification | ||
| Max. Solar Array Open-Circuit Voltage | 160V | |
| Maximum Input Power: | ||
| For 12V System | 960W | |
| For 24V System | 1920W | |
| For 36V System | 2880W | |
| For 48V System | 3840W | |
| Battery Charging Specification | ||
| Charging Technology | MPPT | |
| Charging Algorithm | 3 Stages | |
| Nominal System Voltage | 12V/24V/36V/48V | |
| Battery Voltage Range | 9~60V | |
| Rated Charging Current | 80A | |
| Maximum Efficiency | ≤98% | |
| MPPT Efficiency | >99% | |
| Temperature Compensation | -3mV/°C/2V (default) | |
| Self-Consumption | 44mA/12V; 26mA/24V; 18mA/36V; 12mA/48V | |
| Environment Specification | ||
| Operating Temperature Range | -35°C~+45°C | |
| Humidity Range | ≤95%, Non-condensing | |
| Altitude | <3000m | |
| General Specification | ||
| Protection Level | IP32 | |
| Dimensions | 260x180x75mm | |
| Net Weight | 2kg | |
10. User Tips
Based on common user experiences and questions, here are some tips for optimizing your controller's performance:
- Battery Compatibility: Always verify that your battery type is correctly selected in the controller settings to ensure optimal charging and battery longevity. Incorrect settings can lead to undercharging or overcharging.
- Ventilation is Key: Ensure the controller is installed in a location with excellent airflow. Proper ventilation is crucial for heat dissipation, especially during high-power operation, to prevent the device from entering overtemperature protection mode.
- Secure Connections: Regularly check all wiring connections for tightness. Loose connections are a common cause of system inefficiency and potential hazards like overheating.
- Parallel System Setup: When expanding your system with multiple controllers in parallel, pay close attention to the communication cable connections and ensure each controller has a unique communication code as described in the manual. This ensures proper load balancing and system stability.
- Monitor PV Voltage: If you experience low charging, check the PV input voltage. It might be too low for the controller to operate efficiently. Consider adding more panels or reconfiguring your array to increase voltage.
11. Warranty and Support
Our company reserves the right not to assume any quality warranty responsibilities under certain circumstances, including but not limited to:
- Damage caused by improper transportation, storage, installation, or usage.
- Damage caused by non-professionals or untrained personnel.
- Damage resulting from non-compliance with instructions and safety warnings in this document.
- Operation in environments not meeting specified requirements or beyond parameter ranges.
- Damage from unauthorized disassembly, product alteration, or software modification.
- Damage caused by abnormal natural conditions (force majeure).
- Damage from failure to adhere to local standards and regulations.
- Products outside the warranty period.
For technical support or inquiries, please contact:
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China