Taihua TS-TR/TC

Contents

TS-TR Thermal Resistance Temperature Isolation Transmitter User Manual

Model: TS-TR/TC

1. Introduction

The Taihua TS-TR series thermal resistance signal isolator is designed for industrial temperature measurement applications. It receives thermal resistance or thermocouple signals from the field and converts them into standard current or voltage signals (e.g., 4-20mA, 0-5V, 0-10V). These isolated signals are then transmitted to control rooms, PLCs, DCS, and other display instruments, ensuring high accuracy and reliability in data transmission.

The device features a miniUSB interface for PC connection, allowing users to configure input signal indexing, measurement range, alarm output values, and output measurement range and type. An optional RS485 communication function is available for customized applications. The TS-TR series requires an independent DC 24V power supply and is designed for DIN35mm standard guide rail installation. It provides isolation between input, output, and power supply circuits.

Multiple Taihua TS-TR temperature isolation transmitters mounted on a DIN rail, showing their compact design and green terminal blocks.
Figure 1.1: Taihua TS-TR Transmitters on DIN Rail

2. Product Overview

The TS-TR series offers robust performance with key features:

  • Intelligent Matching: Supports various input types including PT100 thermal resistance, K-type thermocouples, and analog signals, providing isolation, conversion, and anti-interference capabilities.
  • High Accuracy & Stability: Achieves a linearity of one thousandth of the range and a temperature coefficient of ±0.01% F.S/°C.
  • Anti-Interference Capability: Designed to mitigate common ground loop interference and electromagnetic interference, ensuring stable signal transmission in harsh industrial environments.
  • Low Power Consumption: Operates with low power consumption (typically ≤2W), effectively reducing heat generation.
  • Protection Level: The circuit board is fully automatic painted with three-proofing paint, preventing dust, moisture, and electric leakage.
  • USB Interface: Equipped with a miniUSB port for easy connection to a PC for parameter configuration.
Diagram showing intelligent matching of input and output signals for the TS-TR transmitter, connecting to PT100, K-type thermocouple, analog signals as input, and outputting to DCS, PLC, paperless recorder, AMX AXR-RF, and digital display meter.
Figure 2.1: Intelligent Matching and Application Diagram
Diagram illustrating the anti-interference capabilities of the TS-TR-5P11 thermal resistance temperature transmitter, showing how it resists common ground loop interference and electromagnetic interference.
Figure 2.2: Anti-Interference Capability

3. Specifications

Parameter Description
Input Signal Thermal resistance, Resistance, Potentiometer etc. Allowing line resistance: ≤50Ω (Three-wire system)
Wire Break Alarm When the input line is broken, the output current is approximately 22mA (when current output is selected).
Output Signal Current: 4~20mA; 0~20mA; Voltage: 0~5V; 0~10V
Allowed Output Load Resistance RL≤400Ω (for current signal output); RL≥10KΩ (for voltage signal output)
Number of Channels 1 IN/1 OUT, 1 IN/2 OUT, 2 IN/2 OUT
Power Supply DC 24V, Voltage Range: DC 18~32V
Current Consumption ≤80mA (2 IN/2 OUT, 24V Power supply, 20mA Output)
Basic Accuracy ±0.1%F.S or ±0.2%F.S (20°C)
Temperature Drift ±0.1%F.S/°C (-20°C~+55°C)
Response Time ≤1s (0-90%) (TYP)
Dielectric Strength 1500V AC/1 min (among input/output/power supply)
Insulation Resistance ≥100MΩ (among input/output/power supply)
Operating Temperature Range -20~+55°C
Electromagnetic Compatibility In accord with GB/T18268 (IEC61326-1)
Suit for Field Equipment Thermal resistance, Resistance, Potentiometer

Thermal Resistance Input Signal Ranges

Table showing thermal resistance input signal ranges, minimum range, and conversion accuracy for Cu50, Cu100, Pt100, Pt500, Ni100, Ni1000, Ni500, and R5 types, along with selectable current and voltage output signals.
Figure 3.1: Thermal Resistance Input Signal Specifications and Output Options

Thermocouple Input Signal Ranges

Table showing thermocouple input signal ranges, minimum range, and conversion accuracy for B, E, J, K, N, R, S, and T types.
Figure 3.2: Thermocouple Input Signal Specifications

4. Installation and Wiring

The TS-TR transmitter is designed for easy installation on a standard DIN35mm guide rail. Ensure the installation location is free from excessive vibration, moisture, and extreme temperatures outside the operating range (-20°C to +55°C).

4.1 Power Supply

The device requires an independent DC 24V power supply (voltage range 18-32V DC). Connect the power supply to the designated terminals as shown in the wiring diagrams. Ensure correct polarity.

4.2 Input and Output Connections

Connect your thermal resistance, resistance, or potentiometer to the input terminals. The device supports various configurations such as 1 IN/1 OUT, 1 IN/2 OUT, or 2 IN/2 OUT. The output signals (current or voltage) should be connected to your control system (PLC, DCS, etc.) or display instruments.

Refer to the detailed wiring diagrams below for specific connection points for power, input, and output signals. Pay close attention to the terminal markings for IN1, IN2, OUT1, OUT2, and power (DC24V).

Side view of the TS-TR transmitter showing detailed wiring diagram for input, output, and power connections, including terminals for IN1, IN2, OUT1, OUT2, and DC24V power.
Figure 4.1: Detailed Wiring Diagram (Side View)
Angled view of the TS-TR transmitter showing the wiring diagram with input and output terminals clearly marked for connection to DCS/PLC and DC24V power.
Figure 4.2: Wiring Diagram (Angled View)
Top view of the TS-TR transmitter showing the wiring diagram for input, output, and power connections, including bus power option.
Figure 4.3: Wiring Diagram (Top View)
Another angled view of the TS-TR transmitter showing the wiring diagram and terminal labels.
Figure 4.4: Wiring Diagram (Alternative Angled View)

5. Operation and Configuration

The TS-TR transmitter's parameters are configured using a dedicated PC software connected via the miniUSB interface.

5.1 Connecting to PC

  1. Ensure the TS-TR transmitter is powered on.
  2. Connect the miniUSB port on the transmitter to your PC using a compatible USB cable.
  3. Install the dedicated configuration software on your PC (software details typically provided with the product or available from the manufacturer).
Image highlighting the USB interface on the side of the TS-TR transmitter, indicating its use for connecting to a PC for parameter modification.
Figure 5.1: USB Interface Location

5.2 Software Configuration

Once connected, launch the configuration software. The software interface allows you to:

  • Select the input signal type (e.g., Pt100, K-type thermocouple).
  • Set the measurement range for the input signal.
  • Configure alarm output values.
  • Define the output signal type (e.g., 4-20mA, 0-10V) and its corresponding range.
  • Monitor real-time input and output values.

The software provides a user-friendly interface for reading current settings, modifying parameters, and writing them to the device. Ensure to save any changes made in the software to the transmitter's memory.

Screenshot of the software configuration interface for the TS-TR transmitter, showing options for input signal type, measurement range, alarm settings, and output signal configuration for two channels.
Figure 5.2: Software Configuration Interface

5.3 RS485 Communication (Customized)

For models with customized RS485 communication functionality, refer to the specific documentation provided with your device for details on protocol and integration.

6. Maintenance

The TS-TR transmitter is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure optimal performance.

  • Cleaning: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use harsh chemicals or solvents.
  • Connection Integrity: Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
  • Environmental Conditions: Ensure the operating environment remains within specified temperature and humidity ranges to prevent damage.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for the device.

The circuit board is protected with three-proofing paint to resist dust, moisture, and electric leakage, contributing to its durability.

7. Troubleshooting

7.1 Common Issues

  • No Output / Incorrect Output:
    • Verify power supply (DC 24V, 18-32V) is correctly connected and within range.
    • Check input sensor connections for proper wiring and integrity.
    • Confirm output wiring to the control system is correct and load resistance is within specifications (RL≤400Ω for current, RL≥10KΩ for voltage).
    • Ensure the device is properly configured via the PC software (input type, range, output type, range).
  • Wire Break Alarm:
    • If the output current is approximately 22mA (for current output models), it indicates a broken input line. Inspect the input sensor wiring for breaks or loose connections.
  • Interference Issues:
    • While the device has anti-interference capabilities, ensure proper grounding and shielding of input/output cables in extremely noisy environments.
    • Avoid routing signal cables near high-power electrical lines or sources of strong electromagnetic fields.

7.2 Contacting Support

If you encounter issues that cannot be resolved using the above steps, please contact Taihua Instrument customer support for assistance. They are available 24 hours online.

8. User Tips

  • Pre-configuration: It is recommended to configure the transmitter's input and output parameters using the PC software before final installation to ensure it matches your system requirements.
  • Cable Quality: Use high-quality, shielded cables for input and output signals, especially in industrial environments, to maximize the device's anti-interference benefits.
  • Documentation: Keep a record of your configuration settings for quick reference during maintenance or troubleshooting.

9. Warranty and Support

The Taihua TS-TR Thermal Resistance Temperature Isolation Transmitter comes with a 3-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions.

Additionally, Taihua Instrument provides lifetime maintenance for this product. For any technical assistance, troubleshooting, or warranty claims, please contact our customer support team. We offer 24-hour online support to address your inquiries promptly.

Contact Information: Please refer to the manufacturer's official website or your purchase documentation for the most current contact details.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.