Taihua TS-TR

Contents

Taihua TS-TR Series Temperature Isolation Transmitter

High-Precision Thermal Resistance & Thermocouple Signal Isolator

1. Introduction

The Taihua TS-TR series is a high-precision thermal resistance and thermocouple temperature isolation transmitter designed to receive thermal resistance or thermocouple signals from the field. It converts these signals into standard current (4-20mA, 0-20mA) or voltage (0-5V, 0-10V) outputs for transmission to control rooms, PLCs, DCS systems, and display instruments. This device ensures signal isolation and accurate transmission.

The transmitter features a miniUSB interface for PC connection, allowing users to configure input signal indexing, measurement range, alarm output values, and output measurement range and type. An optional RS485 communication function is available for customized applications. The product requires an independent DC 24V power supply and is designed for DIN35mm standard guide rail installation. Input, output, and power supply circuits are mutually isolated to enhance system reliability and prevent interference.

Taihua TS-TR Series Temperature Isolation Transmitter units mounted on a DIN rail
Figure 1: Taihua TS-TR Series Temperature Isolation Transmitters on a DIN rail.

2. Specifications

2.1 Input Parameters

  • Input Signal: Thermal resistance, Resistance, Potentiometer, Thermocouple.
  • Allowed Line Resistance (Thermal Resistance): ≤50Ω (for three-wire system).
  • Wire Break Alarm: When the input line is broken, the output current is approximately 22mA (when current output is selected).

Thermal Resistance Input Types & Ranges:

Table of Thermal Resistance Input Signal Types, Ranges, and Conversion Accuracy
Figure 2: Thermal Resistance Input Signal Specifications.

Thermocouple Input Types & Ranges:

Table of Thermocouple Input Signal Types, Ranges, and Conversion Accuracy
Figure 3: Thermocouple Input Signal Specifications.

2.2 Output Parameters

  • Output Signal: Current: 4~20mA; 0~20mA. Voltage: 0~5V; 0~10V.
  • Allowed Output Load Resistance:
    • RL ≤ 400Ω (for current signal output)
    • RL ≥ 10KΩ (for voltage signal output)

2.3 General Technical Parameters

Parameter Value
Number of Channels 1 IN/1 OUT, 1 IN/2 OUT, 2 IN/2 OUT
Power Supply DC 24V, Voltage Range: DC 18~32V
Current Consumption ≤80mA (2 IN/2 OUT, 24V Power supply, 20mA Output)
Basic Accuracy ±0.1%F.S or ±0.2%F.S (20°C)
Temperature Drift ±0.1%F.S/°C (-20°C~+55°C)
Response Time ≤1s (0-90%)(TYP)
Dielectric Strength 1500V AC/1 min (among input/output/power supply)
Insulation Resistance ≥100MΩ (among input/output/power supply)
Operating Temperature Range -20~+55°C
Electromagnetic Compatibility In accord with GB/T18268(IEC61326-1)
Suit for Field Equipment Thermal resistance, Resistance, Potentiometer
Accuracy, Stability, and Other Performance Parameters
Figure 4: Accuracy, Stability, and Other Performance Parameters.

3. Setup & Installation

3.1 Mounting

The TS-TR series transmitters are designed for DIN35mm standard guide rail installation. Ensure the rail is securely mounted in a suitable enclosure or panel, providing adequate ventilation and protection from environmental factors.

3.2 Wiring Diagrams

Proper wiring is crucial for the correct operation and safety of the device. Refer to the following diagrams for connecting your thermal resistance or thermocouple sensors, power supply, and output devices (PLC, DCS, etc.).

Wiring diagram for TS-TR-5P11 Thermal Resistance Temperature Transmitter
Figure 5: Wiring Diagram for Thermal Resistance Input (TS-TR-5P11).
Wiring diagram for TS-TC-5K1 Thermocouple Temperature Transmitter
Figure 6: Wiring Diagram for Thermocouple Input (TS-TC-5K1).
Application diagram showing input devices, transmitter, and output devices
Figure 7: Typical Application Diagram with various input and output devices.

3.3 Power Supply

Connect a stable DC 24V power supply (within the range of 18-32V DC) to the designated power terminals. Ensure correct polarity to prevent damage to the unit.

4. Operation

4.1 Configuration via USB Interface

The TS-TR transmitter can be configured using a PC and dedicated software. Connect the transmitter to your computer via the miniUSB interface located on the side of the unit.

Image highlighting the USB Interface on the side of the transmitter
Figure 8: Location of the USB Interface.

Once connected, launch the configuration software on your PC. The software allows you to:

  • Set input signal indexing.
  • Define measurement ranges.
  • Configure alarm output values.
  • Select output measurement range and type.
  • Monitor real-time data.
Screenshot of the software configuration interface
Figure 9: Software Configuration Interface.

4.2 RS485 Communication (Customized)

For models with customized RS485 communication functionality, refer to the specific documentation provided with your unit for details on protocol and integration.

5. Maintenance

The TS-TR series transmitters are designed for long-term, reliable operation with minimal maintenance. The circuit board is fully protected with a three-proofing paint to prevent dust, moisture, and electric leakage.

  • Cleaning: Keep the device clean and dry. Use a soft, dry cloth for external cleaning. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the operating environment adheres to the specified temperature range of -20°C to +55°C and appropriate humidity levels.
  • Inspection: Periodically inspect wiring connections for tightness and signs of corrosion or damage.

6. Troubleshooting

If you encounter issues with your TS-TR transmitter, consider the following:

  • No Output / Incorrect Output:
    • Verify the power supply is connected correctly and providing a stable DC 24V (18-32V).
    • Check all input and output wiring connections for proper seating and continuity according to the wiring diagrams (Figures 5, 6).
    • Ensure the input sensor (thermal resistance or thermocouple) is correctly connected and functioning.
    • If using current output, check for a wire break alarm (output current ~22mA).
    • Confirm that the configuration settings (input type, range, output type, range) in the software match your application.
  • Interference Issues:
    • Ensure proper grounding of the system.
    • Minimize electromagnetic interference by separating signal cables from power cables.
    • The device features anti-interference capabilities (Figure 10), but extreme conditions may require additional shielding.
  • Software Connection Problems:
    • Ensure the correct USB drivers are installed on your PC.
    • Verify the miniUSB cable is functional and securely connected.
    • Try restarting the configuration software and reconnecting the device.

For persistent issues, please contact technical support. Taihua provides 24-hour online support.

Diagram illustrating anti-interference capabilities against electromagnetic and common ground loop interference
Figure 10: Anti-Interference Capability.

7. User Tips

  • Quality Assurance: The TS-TR series is built with excellent product quality and undergoes 100% QC inspection before shipment, ensuring reliability.
  • Technical Support: Leverage the strong technical support capability offered by Taihua for any complex application or troubleshooting needs.
  • Global Recognition: Taihua instruments are recognized by national metrology bureaus and exported globally, indicating a high standard of performance.

8. Warranty & Support

The Taihua TS-TR series temperature isolation transmitter comes with a 3-year warranty and lifetime maintenance.

For any technical assistance, questions, or support, please contact Taihua's customer service. They offer 24-hour online support to address your concerns promptly.