1. Introduction
The PORTXVNSA SA5 is a versatile and compact 4-inch IPS LCD multi-function handheld device, combining the capabilities of a spectrum analyzer and a signal generator. Designed for electrical DIY enthusiasts and professionals, it offers a broad frequency range from 100kHz to 5.3GHz, with advanced features like built-in calibration, a high-definition display, and PC connectivity. This manual provides detailed instructions for the safe and effective use of your SA5 device.
2. Product Overview
The SA5 is engineered for precision and portability, featuring a robust design and intuitive controls. Its core functionality includes:
- Spectrum Analyzer: Capable of analyzing frequencies from 0.1-800MHz in normal mode, and up to 5.3GHz with Ultra mode enabled, with observable signal frequencies up to 12GHz.
- Signal Generator: When not in spectrum analyzer mode, it can generate sine waves from 0.1-800MHz, square waves up to 4.4GHz, or RF test signals up to 5.3GHz.


Watch this video for a quick overview of the SA5's features:
3. Key Features
- 4-inch IPS LCD: High-definition display with sensitive touch and intuitive knob design for easy data reading and operation.
- Built-in 5000mAh Battery: Provides at least 3 hours of portable use time. Rechargeable via Type-C port.
- 2-in-1 Multi-function: Operates as both a spectrum analyzer and a signal generator.
- Wide Frequency Range: Spectrum analysis from 0.1-800MHz (normal) up to 5.3GHz (Ultra mode), observable up to 12GHz. Signal generation up to 5.3GHz.
- Switchable Resolution Bandpass Filter: Adjustable filter ranges from 200Hz to 850kHz.
- Optional LNA: Built-in 20dB Low Noise Amplifier (LNA) for enhanced sensitivity.
- Spectrum Display: Displays up to 450 points and supports 4 independently configurable curves.
- MicroSD Card Slot: For storing measurement data, settings, and screenshots. Supports 32GB MicroSD cards.
- Input Attenuator: Step attenuator adjustable from 0dB to 31dB (not compatible with LNA).
- Built-in Calibration: Features an internal signal generator for automatic self-test and input calibration.
- PC Connection: Connects via USB for PC-controlled analysis and data transfer.


4. Package Contents
The SA5 is available in different kits. Please verify your package against the list below:
Standard Kit:
- Main unit (with 5000mAh battery, 4-inch display) x 1
- USB Type-C data cable x 1
- 30cm RG405 SMAJB2/SMAJB2 RF connecting cable x 2
- SMA-SMA barrel connector x 1
- Antenna with SMA connector x 1
- Lanyard touch pad x 1
- Touch pen x 1
Kit 2 (with 32GB MicroSD Card):
- Main unit (with 5000mAh battery, 4-inch display) x 1
- USB Type-C data cable x 1
- 30cm RG405 SMAJB2/SMAJB2 RF cable x 2
- SMA-SMA barrel connector x 1
- Antenna with SMA connector x 1
- Lanyard touch pad x 1
- Touch pen x 1
- 32GB MicroSD card (inserted into main unit) x 1
5. Setup
Follow these steps to set up your PORTXVNSA SA5 device:
- Unpacking: Carefully remove all components from the packaging and verify against the package contents list.
- Charging: Connect the SA5 to a power source using the provided USB Type-C data cable. The device has a built-in 5000mAh rechargeable battery.
- MicroSD Card (Optional): If your kit includes a 32GB MicroSD card, ensure it is properly inserted into the MicroSD card slot on the side of the device. This is used for storing measurement data, settings, and screenshots.
- Antenna/Cables: For spectrum analysis or signal generation, connect the appropriate antenna or RF connecting cables to the SMA connectors on the device as required for your specific application.
- Power On: Locate the power button/knob (often integrated with the rotary function knob) and press or turn it to power on the device.

6. Operating Instructions
The SA5 features a 4-inch IPS LCD and a rotary function knob for navigation and control.
6.1 Basic Navigation
- Touch Screen: Use the touch screen for direct interaction with menus and settings.
- Rotary Knob: Turn the knob to scroll through options or adjust values. Press the knob to confirm selections.
6.2 Spectrum Analyzer Mode
- Access: Select 'Spectrum Analyzer' from the main menu.
- Frequency Range: The default coverage is 0.1-800MHz. To extend this, enable 'Ultra mode' for analysis up to 5.3GHz, and observe signals up to 12GHz.
- Resolution Bandpass Filter: Adjust the filter range (200Hz to 850kHz) to suit your measurement needs.
- Input Attenuator: Set the step attenuator between 0dB and 31dB as required. Note that the attenuator is not compatible with the LNA simultaneously.
- Optional LNA: If higher sensitivity is needed, activate the built-in 20dB Low Noise Amplifier.
- Display: The screen can display up to 450 points and 4 independently configured curves.
6.3 Signal Generator Mode
- Access: Select 'Signal Generator' from the main menu.
- Waveform Selection: Choose between sine waves (0.1-800MHz), square waves (up to 4.4GHz), or RF test signals (up to 5.3GHz).
- Frequency/Amplitude Adjustment: Use the rotary knob and touch screen to set the desired frequency and amplitude for the generated signal.
6.4 Calibration
The SA5 has a built-in calibration signal generator. It performs automatic self-tests and input calibration to ensure measurement accuracy.
6.5 PC Connection
Connect the SA5 to a computer using the USB Type-C cable. The device can function as a PC-controlled spectrum analyzer or signal generator, allowing for data transfer and remote operation.

7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device's exterior and screen. Avoid abrasive cleaners or solvents.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Recharge the device regularly, especially if stored for extended periods.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Ensure the MicroSD card is properly inserted or removed as needed for data management.
8. Troubleshooting
If you encounter issues with your SA5, please refer to the following common problems and solutions:
- Device does not power on: Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and try again.
- Screen is unresponsive: Try restarting the device. If the issue persists, ensure the screen is clean and free of debris.
- Inaccurate readings: Perform a calibration using the built-in calibration function. Ensure all cables and antennas are securely connected. Check for external interference.
- PC connection issues: Verify the USB Type-C cable is correctly connected to both the SA5 and the PC. Ensure necessary drivers (if any) are installed on your computer.
For persistent issues not covered here, please contact customer support.
9. Specifications

| Specification | Details |
|---|---|
| Input Frequency Range | 100kHz to 800MHz (normal mode), up to 6GHz with ULTRA enabled |
| Input Impedance | 50 ohm |
| Input Attenuation | 0dB to 31dB (in 1dB steps, LNA not active) |
| Maximum DC Input | +5V DC |
| Absolute Maximum Input Level | +6dBm (0dB internal attenuation) |
| Absolute Maximum Short-Term Peak Input Power | +20dBm (3dB internal attenuation) |
| Suggested Maximum Input Power | +0dBm (internal attenuation in automatic mode) |
| Best Measurement Input Power | Below -25dBm |
| Input Intercept Point (IIP3) | +15dBm (0dB internal attenuation) |
| 1dB Compression Point | -1dBm (0dB internal attenuation) |
| Power Detector Resolution | 0.5dB |
| Linearity vs Frequency | ±2dB below 5.3GHz, ±5dB between 5.3GHz and 6GHz |
| Absolute Power Level Accuracy | ±2dB after power level calibration |
| Built-in Optional LNA | 20dB LNA with Noise Figure of 5dB |
| Lowest Discernible Signal without LNA | -102dBm at 50MHz (30kHz resolution bandwidth) |
| Lowest Discernible Signal with LNA | -145dBm at 50MHz (200Hz resolution bandwidth) |
| Frequency Accuracy | Equal to the selected resolution bandwidth |
| Phase Noise | -108dBc/Hz at 100kHz offset and -115dBc/Hz at 1MHz offset at 30MHz |
| Spur Free Dynamic Range | 70dB (30kHz resolution bandwidth) |
| Resolution Filters | 0.2, 1, 3, 10, 30, 100, 300, 600, and 850 kHz |
| On-Screen Resolution | 51, 101, 145, 290, or 450 measurement points |
| Scanning Speed | Over 1000 points/second (using largest resolution filters) |
| Automatic Optimization of Scanning Points | Ensures coverage of the whole scan range regardless of the chosen resolution bandwidth |
| Spur Suppression Option | For assessing if certain signals are internally generated or actually present in the input signal |
| Headphone Output | For listening to the demodulated audio (AM only). Stereo connector only, high impedance is louder, short protected. |
| Battery Included | Yes |
| DIY Supplies | Electrical |
| Certification | CE |
| Product Dimensions | 163.5mm * 92mm * 42mm |
| Package Weight | 545g |
| Package Size | 25.5cm * 15.5cm * 5.5cm |
10. User Tips
No specific user tips were available from reviews or Q&A. General advice for optimal performance:
- Always ensure the device is fully charged before extended use.
- Keep the screen clean for accurate touch input.
- Refer to the specifications table for detailed performance limits when conducting measurements.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the seller directly. Keep your proof of purchase for any warranty claims.