1. Introduction
The StarFire SF-2100C 2-axis plasma CNC machine tool controller kit is a comprehensive system designed for precision cutting applications. It is suitable for flame, plasma, high-pressure water jet, and laser cutting machines, finding wide use in industries such as metal processing, advertising, and stone. This system is engineered for high reliability, featuring robust resistance against plasma interference, lightning strikes, and power surges.
The kit includes the SF-2100C CNC controller, SF-HC25K Plasma Height Control Module, JYKB-100-DC24V-T3 Lifting Body, and SF-RF06A Wireless Remote Control.

2. Components Overview
The StarFire SF-2100C kit comprises several key components:
- SF-2100C CNC Controller: The main control unit for the cutting machine.
- SF-HC25K Plasma Height Control Module: Manages the height of the plasma torch.
- JYKB-100-DC24V-T3 Lifting Body: Provides vertical movement for the cutting torch.
- SF-RF06A Wireless Remote Control: Enables remote operation of the system.
- Voltage Divider Board: Essential for plasma voltage sensing.
- Communication Cables: For connecting various modules.

3. Technical Specifications
3.1 SF-2100C CNC Controller
- Processor: Industrial-grade ARM processing chip.
- Display: 7-inch color LCD display.
- Input/Output: 16 channels of optoelectronic isolation input, 16 channels of optoelectronic isolation output.
- Linked Axes: 2 (supports dual-side drive for X or Y axis).
- Maximum Speed: Not less than 24 meters per minute.
- Pulse Equivalent: Flexible adjustment.
- Storage Space: 4GB for user programs, unrestricted processing programs.
- Case Size: 298mm (L) x 202mm (W) x 65mm (H).
- Working Temperature: 0°C to +40°C.
- Storage Temperature: -40°C to +60°C.



3.2 JYKB-100-DC24V-T3 Lifting Body
- Material: 304 stainless steel T-screw, main body aluminum plate (8mm thickness, machined).
- Torch Range: 12mm-38mm (jig included).
- Functionality: Internal plasma starting arc positioning.
- Connector: Four-pin aviation plug.
- Color: Black spray plastic shell.
- Working Stroke: 100mm.
- Working Voltage: DC24V.
- Load Weight: 3kg.
- Size: 320mm (L) x 80mm (W) x 60mm (H).
- Installation Hole Size: 40mm between center distance of left/right holes, 70mm between center distance of upper/lower holes.


3.2.1 Avionics Plug Definition (JYKB-100-DC24V-T3)
- Pin 1: MOT+ (Motor positive)
- Pin 2: MOT- (Motor negative)
- Pin 3: Zero (Positioning normally open zero signal output)
- Pin 4: COM (Positioning normally open COM signal output)
Note: The lifting body has a built-in limit (using a 10A reverse diode), eliminating the need for additional wiring.
3.3 SF-HC25K Plasma Height Control Module

3.3.1 SF-HC25K Pinout Details
| No. | Character | Illustration | Remark |
|---|---|---|---|
| 1 | MOT+ | Output | Lifting motor + |
| 2 | MOT- | Output | Lifting motor - |
| 3 | 24V+ | Output | For 3 lines close to the switch |
| 4 | Zero | Input | Initial location input - proximity switch |
| 5 | Limit+ | Input | Up limited location |
| 6 | Limit- | Input | Down limited location |
| 7 | COM | Public port | Positioning, the public port of the limit switch |
3.3.2 Voltage Divider Board Pinout Details
| Type | Host | 24V Positive | Start arc control | Partial pressure output | 24V ground |
|---|---|---|---|---|---|
| Screw terminal | 24+ | ST | V | 24- |

3.4 SF-RF06A Wireless Remote Control
- Product Name: StarFire Remote Control
- Model: SF-RF06A (for two-axis control systems)
- Matching Controller Models: SF-2100C-QG, SF-2100S, SF-2300S, SF-2310S, SF-5200
- Transmission Distance: 20 meters.


3.4.1 Remote Control to Control System Wiring Diagram
| Control System Model | Pin Number | Pin Definition | Wireless Handheld DB15 Pin |
|---|---|---|---|
| SF-2100C/SF-2100S | 1 | 24V | 1 (24V) |
| 8 | 24G | 8 (24G) | |
| 9 | I8 | 9 (I8) | |
| 10 | I9 | 10 (I9) | |
| 11 | I10 | 11 (I10) | |
| 12 | I11 | 12 (I11) | |
| 13 | I12 | 13 (I12) | |
| SF-2300S DB9 Core Hole | 7 | 24V | |
| 9 | 24G | ||
| 1 | I8 | ||
| 2 | I9 | ||
| 3 | I10 | ||
| 15 (24G) | |||

4. Setup and Installation
Proper installation is crucial for the safe and effective operation of your CNC cutting system. Please follow these guidelines carefully:
4.1 Controller Mounting
- Ensure the mounting surface is stable and free from vibrations.
- Refer to Figure 5 for the SF-2100C controller dimensions and mounting hole locations.
- Allow adequate space around the controller for ventilation and cable connections.
4.2 Wiring Connections
All wiring should be performed by qualified personnel, adhering to local electrical codes and safety standards.
- Power Input: Connect the DC24V/2A power supply to the designated input terminal on the rear of the SF-2100C controller (refer to Figure 4). Ensure correct polarity.
- Motor Connections: Connect the motor cables to the 'Motor' port on the SF-2100C.
- Remote Control Connection: Connect the remote control receiver to the 'Remote' port on the SF-2100C. Refer to Figure 12 and the table in Section 3.4.1 for specific pin definitions.
- Plasma Height Control Module (SF-HC25K) Wiring:
- Connect the SF-HC25K to the SF-2100C using the provided communication cable.
- Connect the lifting motor (JYKB-100-DC24V-T3) to the MOT+ and MOT- terminals on the SF-HC25K (refer to Figure 8 and Section 3.3.1).
- Wire the Voltage Divider Board as shown in Figure 9 and the table in Section 3.3.2. Connect the 'Host' output from the Voltage Divider Board to the appropriate input on the SF-HC25K.
- Ensure all limit switches and proximity switches are correctly wired to the SF-HC25K as per Figure 8 and Section 3.3.1.
- Grounding: Ensure the system is properly grounded to prevent electrical hazards and interference.
4.3 Lifting Body Installation (JYKB-100-DC24V-T3)
- Mount the lifting body securely to your cutting machine's gantry.
- Insert the plasma torch into the jig, ensuring it is firmly clamped within the 12mm-38mm range.
- Connect the four-pin aviation plug from the lifting body to the corresponding port on the SF-HC25K, observing the pin definitions in Section 3.2.1.
5. Operating Instructions
The SF-2100C system offers a user-friendly interface and various functions to optimize your cutting process.
5.1 Basic Operation
- Power On: Ensure all connections are secure, then apply DC24V power to the system. The 7-inch color LCD display will illuminate.
- Interface: The system features a dynamic graphic display with automatic tracking of moving points. The operation interface can be converted between Chinese and English.
- Program Loading: Use a USB flash drive to load cutting programs into the system.
- Graphic Selection: Access the seasonal parts library with 24 types of graphics (expandable and customizable) for common machining parts. The system is compatible with StarCAM, IBE (Germany), and FASTCAM nesting software.
- Magnification: Graphics can be magnified 1-8 times for detailed viewing.
5.2 Key Functions and Parameters
The system provides extensive control over cutting operations:
- Slit Compensation: Automatically compensates for the kerf width. The system can test the reasonableness of compensation in the program and generate reports.
- Breakpoint Recovery: Automatically recovers from power outages and remembers the last breakpoint.
- Segment and Perforation Point Selection: Allows arbitrary selection of processing segments and perforation points.
- Epitaxial Perforation: Suitable for thick plates.
- Bridging Function: Suitable for thin plates.
- Fallback: Enables returning to previous steps.
- Cutting Transfer: Cutting operations can be transferred at any time during the process.
- Small Line Segment Processing: Ensures smooth movement, ideal for intricate designs in advertising or ironwork.
- Wireless Remote Control: Use the SF-RF06A for remote operation. Press the 'S' key continuously on the controller to enable/disable manual control via the remote.
5.3 Parameter Description
- Speed Parameters: Adjust starting speed, adjustment time, and maximum speed limit for each axis.
- System Parameters: Configure electronic gear ratio, machine origin, reference point, reverse clearance, line offset, and soft positive/negative limits for each axis.
- Flame Cutting Parameters: Set ignition delay, preheating delay, cutting gun lifting/lowering delay, perforation cutting gun lifting/lowering, and perforation delay.
- Plasma Parameters: Configure cutting gun positioning delay, M-command for arc initiation/interruption, arc voltage detection selection, positioning detection selection, and perforation delay.
- Control Parameters: Select flame/plasma mode, set processing speed limits, edge perforation options, and metric/imperial units.
- Storage Function: Save modified parameters to the parameter area.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your StarFire CNC system.
- Cleaning: Keep the controller and other components free from dust, debris, and moisture. Use a soft, dry cloth for cleaning. Avoid abrasive cleaners or solvents.
- Cable Inspection: Periodically check all cables for signs of wear, damage, or loose connections. Replace damaged cables immediately.
- Ventilation: Ensure the SF-2100C controller has adequate ventilation to prevent overheating. Keep ventilation openings clear.
- Lifting Body (JYKB-100-DC24V-T3): Inspect the T-screw and jig for wear. Lubricate moving parts as recommended by general industrial practices for similar components.
- Software Updates: Regularly check for and apply software updates using a USB flash drive to ensure the system operates with the latest features and bug fixes.
7. Troubleshooting
This section provides solutions to common issues you might encounter.
- System Not Powering On:
- Check the DC24V power supply connection and ensure it is providing the correct voltage.
- Verify that the power cable is securely connected to the controller.
- Cutting Path Inaccurate:
- Check the electronic gear ratio settings in the system parameters.
- Verify that the machine origin and reference points are correctly set.
- Ensure slit compensation is correctly configured for the material and torch being used.
- Plasma Arc Not Initiating:
- Check plasma parameters, specifically 'M-command for arc initiation' and 'cutting gun positioning delay'.
- Ensure the Voltage Divider Board is correctly wired and functioning.
- Verify connections to the plasma power source.
- Torch Height Issues:
- Inspect the JYKB-100-DC24V-T3 lifting body for mechanical obstructions or damage.
- Check the SF-HC25K module's connections and parameters, especially limit switch inputs.
- Ensure the torch is securely clamped in the jig.
- Remote Control Not Responding:
- Verify the remote control receiver is properly connected to the SF-2100C.
- Ensure the 'S' key on the controller has been pressed to enable manual control via the remote.
- Check the remote control's battery (if applicable).
- Interference Issues:
- Ensure proper grounding of the entire system.
- Check for loose wiring or unshielded cables near high-frequency sources.
8. User Tips
N/A - No specific user tips derived from reviews or Q&A were provided.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized StarFire dealer or the point of purchase. Keep your purchase records handy when contacting support.