1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your meterk Ultrasonic Underwater Ranging Sensor. This sensor is designed for underwater applications, offering precise distance measurement and obstacle avoidance capabilities, particularly suitable for ROVs and swimming pool robots.
2. Product Features
The meterk Ultrasonic Underwater Ranging Sensor is engineered with advanced features for reliable underwater performance:
- Compact Size: Designed for easy integration into various underwater systems.
- High Precision: Provides accurate distance measurements.
- Small Blind Spot: Minimizes undetected areas for improved obstacle avoidance.
- High Protective Rating (IP68): Ensures complete waterproofing and dust protection for submerged operation.
- Anti-Static Protection: Features ±8KV static protection at 485 output, compliant with IEC61000-4-2 standard (touch discharge model).
- Wide Voltage Compatibility: Adaptable to various power supply configurations.
- Configurable Parameters: Supports modification of module address, angle, and baud rate.

3. Specifications
| Parameter | Value |
|---|---|
| Item Type | Ultrasonic Underwater Ranging Sensor |
| Material | Polymer |
| Temperature Compensation | Yes |
| Water Proof Rating | IP68 |
| Operating Temperature | -15℃ to 55℃ |
| Baud Rate | 115200bps |
| Static Protection | ±8KV at 485 output (IEC61000-4-2 compliant) |
| Standby Current | ≤15mA |
| Average Operating Current | ≤20mA |
| Output Response Time | ≤20ms |
| Power on Working Time | ≤1s |
| Working Period | Controlled |
| Output Method | 485 |
| Distance Measurement Accuracy (within 2m) | ±(0.5 + S x 0.5%) |
| Distance Measurement Accuracy (over 2m) | ±(1 + S x 1%) |
| Dimensions (Diameter x Length) | 28±0.5mm (1.10±0.02in) x 34±0.5mm (1.34±0.02in) |
| Detection Angle | 25° |
4. Package Contents
Your package should contain the following item:
- 1 x Ultrasonic Underwater Ranging Sensor
5. Setup and Installation
The sensor is designed for direct installation and use. Follow the wiring instructions and consider the physical dimensions for proper placement.
5.1. Wiring Diagram and Interface Definition
Connect the sensor according to the following interface definitions:

| Cable Number | Cable Name | Cable Description | Note |
|---|---|---|---|
| 1 | VCC | Power Input Cable | Power Ground Pin |
| 2 | GND | Power Grounding Cable | Power Input Pin |
| 3 | RX/B | Functional Cable | Functional Cable (1) |
| 4 | TX/A | Functional Cable | Functional Cable (1) |
5.2. Physical Installation
Ensure the sensor is mounted securely in the desired underwater location. The sensor has a detection angle of 25°. Consider its dimensions (28±0.5mm diameter, 34±0.5mm length) for integration into your system.

6. Operation
The sensor operates by emitting ultrasonic waves and measuring the time it takes for the echo to return, thereby calculating distance. It outputs data via a 485 interface.
- Primary Use: Ideal for underwater robot obstacle avoidance, automatic control systems, underwater distance measurement, and integration into underwater cleaning equipment.
- Working Period: The sensor's working period is controlled, allowing for integration into various system cycles.
- Data Output: Distance data is transmitted via the 485 communication protocol.

7. Maintenance
To ensure optimal performance and longevity of your ultrasonic underwater ranging sensor, adhere to the following maintenance guidelines:
- Water Quality: The sensor is designed for use in relatively clean water environments, such as swimming pools. Avoid prolonged exposure to highly turbid or chemically aggressive water, which may affect its performance or lifespan.
- Cleaning: Periodically inspect the sensor's surface for any buildup of algae, debris, or mineral deposits. Gently clean the sensor face with a soft cloth and fresh water. Do not use abrasive materials or harsh chemicals.
- Cable Inspection: Regularly check the cable for any signs of wear, cuts, or damage. Ensure all connections remain secure and watertight.
8. Troubleshooting
If you encounter issues with your sensor, consider the following general troubleshooting steps:
- No Output/Incorrect Readings:
- Verify all wiring connections are correct and secure according to the Interface Definition.
- Check the power supply to ensure it meets the sensor's requirements.
- Ensure the sensor face is clean and free from obstructions.
- Confirm the baud rate and other communication parameters are correctly configured in your receiving system.
- Intermittent Operation:
- Inspect the cable for any damage or loose connections that might cause intermittent contact.
- Ensure the operating temperature is within the specified range (-15℃ to 55℃).
For complex issues or if troubleshooting steps do not resolve the problem, please contact technical support.
9. User Tips
- Application Specifics: While suitable for swimming pool robot obstacle avoidance, for other specialized underwater scenarios, it is highly recommended to consult with technical engineers to evaluate and adjust sensor parameters for optimal performance.
- Parameter Adjustment: Utilize the sensor's capability to modify module address, angle, and baud rate to fine-tune its operation for your specific application needs.
10. Warranty and Support
Specific warranty details for this product are not provided in the available documentation. For any technical assistance, support, or inquiries regarding warranty, please contact the seller or manufacturer directly through your purchase platform.