1. Product Overview
The MILESEEY TR20 and TR20 Pro are advanced handheld thermal imaging cameras designed for various applications including HVAC, electrical, automotive, and building inspections. They feature high-resolution thermal sensors, intelligent temperature detection, and a user-friendly interface.
1.1 Components and Controls

- USB-C Charging Port: For charging the device.
- LCD Display: Shows thermal images, temperature readings, and menu options.
- Power/Return Button: Turns the device on/off and navigates back in menus.
- SET Button: Enters menus and confirms selections.
- Memory Button: Accesses stored pictures and videos.
- Navigation Button (Up/Down/Left/Right): Navigates menus and adjusts values.
- Thermal Camera: Captures infrared thermal data.
- Visible Light Camera (TR20 Pro Only): Captures visual images for fusion modes.
- Trigger: Short press to take pictures, long press to start/stop video recording.
1.2 Display Icons

- Battery Level Indicator: Shows remaining battery charge.
- Center Temperature: Temperature reading at the center of the screen.
- Min./Max. Temperature Points: Indicates the lowest and highest temperatures detected in the current view.
- Temperature Bar: Visual scale representing the temperature range.
- Date & Time: Current date and time.
- Detection Distance: The distance at which the measurement is taken.
- Emissivity: The emissivity value set for the object being measured.
- Temperature Range Indicator: Shows the current temperature measurement range.
2. Safety Instructions
- For accurate measurements and your safety, always follow the instructions in this manual. Damage due to improper use may void the warranty.
- Clean the outer casing with a wet cloth and mild soap. Do NOT use abrasives, isopropyl alcohol, or other solvents.
- Avoid using the product in flammable, explosive, steamy, or corrosive environments.
- Stop using the product immediately if it is damaged or modified to prevent inaccurate results.
- Set the correct emissivity value for the object being inspected to ensure accurate temperature readings.
- Allow the device to stabilize for 2 minutes after power-on before taking measurements.
- Do not use the product for measurements during or immediately after charging, as internal temperature rise can affect accuracy.
3. Getting Started
3.1 Power On/Off
Press and hold the Power button (①) to turn the device on or off.
4. Operation Instructions
4.1 Settings Menu
Press the SET button (SET) to enter the setting menu. Use the Up/Down (▲/▼) buttons to select items and adjust values. Press SET again to confirm. Press the Power button (①) to return to the previous page.
Available Settings:
- Emissivity (0.01~0.99): Adjust for different materials to ensure accurate temperature readings.
- Distance (0.3m~3m): Set the measurement distance.
- Ambient Temperature: Displays the ambient temperature.
- Temperature Range: Select normal (-20°C~150°C) or high (100°C~550°C) range.
- Temperature Units (°C/°F): Switch between Celsius and Fahrenheit.
- Palette: Choose from 8 color palettes (White Hot, Black Hot, Iron, Rainbow, Blend, Red Hot, Blue Hot, Green Hot).

Figure 3: Available Thermal Color Palettes - HI/LO Alarm: Configure high/low temperature alarms, buzzer on/off, and temperature thresholds.
- Display: Customize display options (Hotspot/Coldspot, Centre Spot, Palette, Measure Parameter, Clock & Battery).
- Display Brightness: Adjust screen brightness (Low/Mid/High).
- Date & Time: Set current date and time using navigation buttons.
- Correction: Manual calibration option.
- USB Mode: Select USB Disk (for file transfer) or USB Camera (for live streaming).
- Snap Mode: Set alarm-triggered or time-triggered photo/video capture.
- Auto Power Off: Set automatic shutdown time (5min/10min/30min/Off).
- Language: Select device language.
- Format Disk: Format internal memory.
- Factory Reset: Restore default settings.
- Device Info: View device information.
4.2 Image Mode (TR20 Pro Only)
Press the SET button (SET) to enter the Image Mode menu. Use the Up/Down (▲/▼) buttons to select among Digital, Fusion Rate, Fusion Offset, PIP (Picture-in-Picture), and Thermal modes. Press SET again to confirm.

4.3 Temperature Width
Adjusting the temperature width makes the thermal imaging more prominent within a specific temperature range. Press SET to enter the Temperature Width setting, then press SET again to select which temperature value to adjust (maximum, minimum, or both). Use the Up/Down (▲/▼) buttons to adjust the value. When the lock icon is open, the value can be adjusted.
4.4 Regional Temperature Detection
Press the SET button (SET) to enter Region mode. Press and hold the navigation buttons to expand or narrow the measurement box. In this mode, the device only measures temperature within the defined box.
4.5 Taking Pictures and Videos
- Pictures: Short-press the Trigger button.
- Videos: Long-press the Trigger button to start and stop recording.
*Pictures and videos are automatically saved to the internal memory.
4.6 Viewing and Deleting Pictures/Videos
Press the Memory button (🖼️) to enter the picture and video memory. Press the SET button (SET) to enter a folder, file, picture preview, or video playback.
- View Pictures: In the full-screen preview, use the Left/Right (◀/▶) buttons to switch between pictures.
- Delete Pictures: In the file page, use Left/Right (◀/▶) to select, or press SET in the preview page to delete the current picture or empty the folder.
- Video Playback: Press SET in the preview page to play/pause videos.
- Delete Videos: Use Left/Right (◀/▶) in the file page or in the preview page to delete the current video or empty the folder.
5. Maintenance
5.1 Cleaning
Clean the outer casing of the device with a soft, damp cloth and mild soap. Do not use harsh chemicals, abrasive cleaners, or solvents as they may damage the device.
5.2 Storage
Store the device in a dry, cool place within the specified storage temperature range (-20°C to 60°C). Avoid extreme temperatures and high humidity.
5.3 Battery Care
To prolong battery life, avoid fully discharging the battery frequently. Recharge the device using the provided USB-C cable. If storing for extended periods, charge the battery to approximately 50% every few months.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Inaccurate temperature readings | Incorrect emissivity setting; device not stabilized; measurement during/after charging. | Adjust emissivity for the target material; wait 2 minutes after power-on; avoid measuring during/after charging. |
| Device won't power on | Low battery; device malfunction. | Charge the battery; if problem persists, contact support. |
| Screen frozen or unresponsive | Software glitch. | Perform a soft reset by holding the Power button for 10 seconds. |
| Cannot save pictures/videos | Memory full; corrupted memory. | Delete old files or format the disk (backup important data first). |
7. Specifications
| Feature | Specification |
|---|---|
| Model | TR20/TR20 Pro |
| IR Resolution | 320*240 |
| FOV (Field of View) | 50°× 37.2° |
| NETD (Thermal Sensitivity) | < 40mK |
| Frame Rate | 50Hz |
| Digital Camera Resolution | 2MP (TR20 Pro Only) |
| Display | 2.8" LCD Display, 480*640 |
| Temperature Range | -20°C to 550°C |
| Measuring Accuracy | ±2% |
| Memory | 8GB |
| Distance Range | 0.3m~3m |
| Battery Capacity | 5,000mAh |
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -20°C to 60°C |
| Charging Port | USB-C |
| Dimensions | 224*91.6*76mm |
*All data are measured and provided by the MILESEEY Lab; actual use may vary.
8. User Tips
- For optimal thermal imaging clarity, especially for small details, ensure the correct emissivity is set for the material you are inspecting.
- When comparing thermal images, consider using the fusion modes (TR20 Pro) to overlay visual details for better context.
- Regularly check the battery level before starting long inspection tasks to avoid interruptions.
- If you notice discrepancies in temperature readings, recalibrate the device or perform a factory reset if necessary.
9. Disposal
9.1 Battery Disposal
Waste batteries must not be disposed of with household garbage. Please dispose of them at designated collection stations for proper handling, in accordance with local regulations.
9.2 Product Disposal
This product should not be discarded with regular domestic waste. It must be disposed of in accordance with local regulations and guidelines specific to your country/region. Consult local authorities for proper disposal methods.
10. Warranty and Support
10.1 Copyrights
Product specifications may change without prior notice. All rights for final interpretation are reserved by Mileseey Technology Co., Ltd. All trademarks, product images, and technical parameters belong to Mileseey Technology Co., Ltd. All rights reserved.
10.2 Contact Us
Shenzhen Mileseey Technology Co., Ltd.
Address: No.3601 Block A, Tanglang Town Plaza West, Fuguang Community, Taoyuan Street, Nanshan District, Shenzhen, China
Store: www.mileseeytools.com
E-mail: service@mileseey.com
10.3 Additional Resources
A detailed user manual in PDF format is available for download: MILESEEY TR20 | TR20 Pro User Manual (PDF)