Sanwa YX-360TRF

Contents

SANWA YX-360TRF Analog Multimeter Tester User Manual

Model: YX-360TRF | Brand: Sanwa

1. Introduction

This manual provides essential information for the safe and effective operation of your SANWA YX-360TRF Analog Multimeter Tester. Please read this manual thoroughly before use and keep it for future reference. The YX-360TRF is a robust analog multimeter designed for various electrical measurements, featuring a drop-shock proof design and a clear pointer display.

Video: SANWA YX-360TRF Product Overview

2. Safety Information

Always observe the following safety precautions to prevent electric shock, injury, or damage to the meter:

  • Ensure the meter is in good working condition before use.
  • Do not use the meter if it appears damaged or if the test leads are compromised.
  • Always set the function switch to the appropriate range before connecting the test leads to the circuit under test.
  • Do not exceed the maximum input values for each range.
  • Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
  • Replace batteries and fuses only with the specified type and rating.
  • Keep fingers behind the finger guards on the test probes during measurements.
  • Disconnect the test leads from the circuit before changing functions or ranges.

3. Product Overview

The SANWA YX-360TRF is an analog multimeter featuring a large, easy-to-read scale and a robust design. It includes test leads and a hand strap for convenience.

Components:

  • Pointer Display: Shows measurement readings.
  • Function/Range Selector Dial: Used to select the desired measurement type and range.
  • Zero Ohm Adjustment (ΩADJ): For adjusting the pointer to zero when measuring resistance.
  • Test Lead Jacks: For connecting the red (+) and black (-) test leads.
  • Protective Body Cover: Enhances durability and provides a stand function.
Front view of SANWA YX-360TRF Analog Multimeter

Image: Front view of the SANWA YX-360TRF Analog Multimeter.

Side view of SANWA YX-360TRF Analog Multimeter with kickstand

Image: Side view showing the protective cover acting as a kickstand.

SANWA YX-360TRF Analog Multimeter with test leads

Image: Multimeter with included test leads.

4. Specifications

Table of specifications for SANWA YX-360TRF Multimeter

Image: Detailed specifications table.

SANWA YX-360TRF Key Specifications
Feature Description
Model Number YX-360TRF
Display Type Pointer Display
Operating Mode Manual Range
DC Voltage (DCV) 0.1V (20kΩ/V), 0.25/2.5/10/50 (20kΩ/V), 250/1000V (9kΩ/V), ±5/25V (40kΩ/V)
AC Voltage (ACV) 10/50/250/750V (9kΩ/V)
DC Current (DCA) 50µA/2.5mA/25mA/0.25A
Measuring Resistance Range 2k/20k/200k/2MΩ (X1/X10/X100/X1k), 200MΩ (X100k)
Measuring Inductance Range 10µF (Capacitance)
Load Current (LI) 0~150m/15m/1.5m/150µA/1.5µA
dB Measurement -10dB~+22dB (for 10VAC) ~+62dB
DC High Voltage DC25kV (optional probe "HV-10T" is necessary)
hFE 1000 at X10 range (optional probe "HFE-6T" is necessary)
Battery R6 (IEC) or UM-3 (1.5V) x 2
Fuse φ5.2 x 20mm (250V/0.5A)
Dimensions H159.5 x W129 x D41.5mm
Mass Approx. 320g
Operating Temperature 0 - 40 ℃
Certification CE
Origin Mainland China
Standard Accessories Instruction manual, Hand strap

5. Setup

5.1. Battery Installation

  1. Ensure the multimeter is turned OFF.
  2. Locate the battery compartment cover on the back of the meter.
  3. Open the cover and insert two R6 (IEC) or UM-3 (1.5V) batteries, observing the correct polarity (+/-).
  4. Close the battery compartment cover securely.

5.2. Connecting Test Leads

  1. Insert the red test lead into the positive (+) jack.
  2. Insert the black test lead into the negative (-) or COM jack.
  3. Ensure the connections are firm.

6. Operating Instructions

The SANWA YX-360TRF operates with a manual range selection. Always select the appropriate function and range before making a measurement.

6.1. DC Voltage (DCV) Measurement

  1. Set the function switch to the desired DCV range (e.g., 0.25V, 2.5V, 10V, 50V, 250V, 1000V). Start with the highest range if the voltage is unknown.
  2. Connect the red test lead to the positive side of the circuit and the black test lead to the negative side.
  3. Read the voltage value from the DCV scale on the display.

6.2. AC Voltage (ACV) Measurement

  1. Set the function switch to the desired ACV range (e.g., 10V, 50V, 250V, 750V). Start with the highest range if the voltage is unknown.
  2. Connect the test leads across the AC voltage source.
  3. Read the voltage value from the ACV scale on the display.

6.3. DC Current (DCA) Measurement

  1. Set the function switch to the desired DCA range (e.g., 50µA, 2.5mA, 25mA, 0.25A).
  2. Important: The circuit must be broken to measure current. Connect the multimeter in series with the circuit.
  3. Connect the red test lead to the higher potential side and the black test lead to the lower potential side.
  4. Read the current value from the DCA scale.

6.4. Resistance Measurement

  1. Ensure the circuit under test is completely de-energized.
  2. Set the function switch to the desired Resistance range (e.g., X1, X10, X100, X1k, X100k).
  3. Short the test leads together and adjust the ΩADJ knob until the pointer reads zero.
  4. Connect the test leads across the component to be measured.
  5. Read the resistance value from the Ω scale and multiply by the range multiplier (e.g., X1, X10).

6.5. Capacitance Measurement

The meter supports capacitance measurement up to 10µF. Refer to the specific scale and instructions on the meter face for accurate readings, noting that pointer indication reflects the maximum movement by charged current in the capacitor.

6.6. dB Measurement

The meter can measure dB values from -10dB to +22dB (for 10VAC) up to +62dB. Use the appropriate ACV range and read from the dB scale.

6.7. hFE Measurement

hFE measurement (transistor gain) is available at the X10 range, with an optional probe "HFE-6T" necessary for this function.

7. Maintenance

7.1. Cleaning

Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents.

7.2. Battery Replacement

When the meter's pointer becomes sluggish or inaccurate, it's time to replace the batteries. Follow the steps in Section 5.1. Always use two R6 (IEC) or UM-3 (1.5V) batteries.

7.3. Fuse Replacement

If the current measurement function stops working, the fuse may be blown. Replace it with a φ5.2 x 20mm (250V/0.5A) fuse. Refer to the meter's internal diagram for fuse location, typically accessible by opening the back cover.

8. Troubleshooting

  • No reading/Pointer not moving: Check battery charge, ensure test leads are properly connected, verify function and range selection, check for blown fuse (for current measurements).
  • Inaccurate readings: Ensure proper range selection, perform ΩADJ for resistance measurements, check battery level.
  • Meter appears damaged: Discontinue use immediately and contact support.

9. User Tips

  • Verify Authenticity: While the product is branded Sanwa, its origin is Mainland China. If you have specific requirements for 'Made in Japan' products, please verify product details carefully before purchase.
  • Start High, Go Low: When measuring unknown voltages or currents, always start with the highest range setting to prevent damage to the meter, then gradually decrease the range for a more precise reading.
  • Zero Ohm Adjustment: For accurate resistance measurements, always perform the zero ohm adjustment by shorting the probes and turning the ΩADJ knob before testing.

10. Warranty & Support

For any issues or inquiries regarding your SANWA YX-360TRF Analog Multimeter Tester, please refer to the official user manual PDF for detailed warranty information and contact the seller or manufacturer's customer support. A PDF version of the user manual is available for download from the product page or by searching for "SANWA YX-360TRF user manual PDF" online.

Note: Shipping companies typically do not accept liquids, powders, and dry batteries. Please be aware of this when handling or returning the product.

11. Frequently Asked Questions (FAQ)

Q: Is this a genuine Sanwa YX-360TRF?

A: The product is branded Sanwa and manufactured in Mainland China. For specific authenticity concerns, please refer to the product's official documentation and seller information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.