JIKONG JK-B15A24S

Contents

JIKONG JK-B15A24S Active Balancer Instruction Manual

Model: JK-B15A24S

1. Product Overview

The JIKONG JK-B15A24S is an advanced active balancer designed for energy storage systems, compatible with Li-ion, LiFePO4, and LTO battery types. It features a 15A balance current and supports battery configurations from 2S to 24S. This smart BMS (Battery Management System) includes Bluetooth connectivity for monitoring and control via a mobile application, offering comprehensive protection functions such as overcharge, over-discharge, overcurrent, and short circuit protection.

JIKONG JK-B15A24S Active Balancer and accessories
Figure 1: JIKONG JK-B15A24S Active Balancer and included accessories.
JIKONG JK-B15A24S Active Balancer with key features
Figure 2: JIKONG JK-B15A24S Active Balancer highlighting Bluetooth function, 15A balance current, 2S-24S battery strings, 40-100V supply voltage, and compatibility with Li-ion/LiFePO4/LTO battery types.
Video 1: Product unboxing and overview of the JIKONG Active Balancer and its components.

2. Specifications

The JK-B15A24S Active Balancer offers robust performance and features for various battery configurations.

General Specifications (Model JK-B15A24S)

ParameterValue
Product ModelJK-B15A24S
Battery Type Strings2S - 24S
Balance MethodActive Balance
Equalizing CurrentIndependent Settings
Maximum Balanced Current15A
Acquisition Balanced Current±3mV
Supply Voltage40-100V
Operating Temperature Range-20°C to 70°C
CommunicationBluetooth (BT)
Active Equalizer FunctionSupport
Supporting Parallel ConnectionSupport
Support SoftwareAndroid/iOS/HarmonyOS
Product Size234.5*170*53mm
Table of JK-B15A24S product parameters
Figure 3: Detailed product parameters for the JK-B15A24S model.

Additional Features

  • Certifications: CE, RoHS
  • Protection Functions: Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection, Dropout Protection, Over temperature protection
  • Usage Scenarios: Power BMS, Energy Storage BMS, 3C Digital BMS
Dimensions of the JIKONG Active Balancer
Figure 4: Physical dimensions of the JIKONG Active Balancer (234.5mm x 170mm x 53mm).

3. Setup and Installation

Careful wiring is crucial for the safe and effective operation of your active balancer. Always ensure power is disconnected before making any connections.

Wiring Diagrams

Refer to the following diagrams for correct wiring based on your battery configuration:

24S Wiring Diagram for Initiative Balancer
Figure 5: Wiring diagram for a 24S battery configuration with the Initiative Balancer.
20S Wiring Diagram for Initiative Balancer
Figure 6: Wiring diagram for a 20S battery configuration with the Initiative Balancer.
External Power Supply Wiring Diagram for Initiative Balancer
Figure 7: Wiring diagram for connecting an external DC power supply (40-100V) to the Initiative Balancer.
Booster Circuit Wiring Diagram for Initiative Balancer
Figure 8: Wiring diagram for integrating a booster circuit with the Initiative Balancer.
Cascade Mode Wiring Diagram for Initiative Balancer
Figure 9: Wiring diagram for connecting multiple Initiative Balancers in cascade mode.

General Installation Steps

  1. Prepare Battery Pack: Ensure all individual cells in your battery pack are at a similar state of charge before connecting the balancer.
  2. Connect Balance Wires: Carefully connect the balance wires from your battery cells to the corresponding ports on the balancer, following the appropriate wiring diagram for your series count (e.g., 24S, 20S). Ensure correct polarity and sequence.
  3. Connect Power Supply: If using an external power supply, connect it according to the diagram. The balancer supports a supply voltage of 40-100V.
  4. Secure Connections: Double-check all connections to ensure they are secure and free from shorts.
  5. Initial Power-Up: Apply power to the system. Observe the indicator lights on the balancer for proper operation.

4. Operating Instructions

The JIKONG JK-B15A24S Active Balancer is designed for automatic balancing, but its smart features allow for monitoring and configuration via a mobile application.

Automatic Balancing

Once correctly installed and powered, the balancer will automatically begin to equalize the voltage of individual cells within the battery pack. The active balancing mechanism works to transfer energy from higher voltage cells to lower voltage cells, ensuring optimal battery health and longevity.

Mobile Application (Bluetooth)

The balancer features Bluetooth connectivity, allowing you to monitor and adjust settings using a dedicated mobile application (available for Android, iOS, and HarmonyOS).

  1. Download App: Search for the official JIKONG BMS application on your device's app store.
  2. Connect via Bluetooth: Enable Bluetooth on your mobile device and open the JIKONG BMS app. The app should detect the balancer. Select your device to connect.
  3. Monitor Parameters: The app provides real-time data on individual cell voltages, overall battery voltage, balance current, and wire resistance.
  4. Adjust Settings: Access the 'Settings' section within the app to configure parameters such as balance trigger voltage, maximum balance current, and power-off voltage.
Screenshot of the mobile application interface showing cell voltage, wire resistance, and settings
Figure 10: Screenshot of the JIKONG mobile application interface, displaying real-time battery status and configuration options.

5. Maintenance

To ensure the longevity and optimal performance of your JIKONG Active Balancer, follow these maintenance guidelines:

  • Regular Inspection: Periodically inspect all wiring connections for any signs of wear, corrosion, or looseness. Ensure all connectors are firmly seated.
  • Cleanliness: Keep the balancer unit clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
  • Environmental Conditions: Ensure the balancer operates within its specified temperature range (-20°C to 70°C) and in a dry environment. Avoid exposure to extreme temperatures, humidity, or direct sunlight.
  • Firmware Updates: Check the official JIKONG website or app for any available firmware updates. Keeping the firmware updated can improve performance and add new features.

6. Troubleshooting

If you encounter issues with your JIKONG Active Balancer, refer to the following troubleshooting tips:

Common Issues and Solutions

  • No Power/Indicator Lights Off:
    • Check the external power supply connection and ensure it is within the 40-100V range.
    • Verify all power cables are securely connected.
  • Balancing Not Occurring:
    • Confirm that all balance wires are correctly connected to the battery cells and the balancer. Incorrect wiring can prevent balancing.
    • Check the cell voltage differences via the mobile app. Balancing typically activates when cell voltages exceed a set trigger threshold.
    • Ensure the battery pack is within the supported 2S-24S range.
  • Bluetooth Connectivity Issues:
    • Ensure Bluetooth is enabled on your mobile device.
    • Restart the mobile application and try reconnecting.
    • Move closer to the balancer to ensure a strong Bluetooth signal.
    • Check if the balancer is already connected to another device.
  • Overcharge/Over-discharge Protection Triggered:
    • This indicates that a cell or the entire pack has reached its upper or lower voltage limit. The balancer will stop charging/discharging to protect the battery.
    • Check your charger/load settings and battery specifications.

If the issue persists after attempting these steps, please contact customer support.

7. User Tips

  • Voltage Compatibility: The JK-B15A24S is designed for a wide range of battery series (2S-24S) and operates with a supply voltage of 40-100V. This means it can effectively manage battery packs that might reach higher voltages, such as a 48V lithium battery pack that charges up to 58V, as long as the peak voltage remains within the 100V limit. Always verify your battery pack's maximum voltage is within the balancer's operating range.
  • Initial Cell Voltage Check: Before connecting the balancer, it is highly recommended to measure and record the voltage of each individual cell in your battery pack. This helps in identifying any significantly unbalanced cells beforehand and can aid in troubleshooting if issues arise.
  • Cable Management: Organize and secure all wiring neatly. This not only improves safety by preventing accidental shorts but also makes future maintenance and troubleshooting easier.
  • App Monitoring: Regularly use the mobile application to monitor your battery's health. Pay attention to cell voltage differences and overall pack performance to catch potential issues early.

8. Warranty and Support

JIKONG products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your vendor. In case of technical issues or questions, please reach out to the seller or manufacturer's customer support for assistance.

© 2024 JIKONG. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.