1. Introduction
The TAXNELE TXATS-125/2P-EW Dual Power Automatic Transfer Switch (ATS) is a PC Level micro household power transfer switch designed to ensure continuous, reliable, and safe power supply. When the normal city power becomes abnormal, the ATS automatically switches to a backup power source without interruption. This device can also be controlled remotely through the eWeLink APP, allowing users to monitor and manage power switching, and even specify scheduled switching times.
2. Safety Information
Please read and understand all safety instructions before installing, operating, or maintaining this device. Failure to follow these instructions may result in serious injury or property damage.
- Installation and maintenance should only be performed by qualified personnel.
- Always disconnect power from both normal and backup sources before working on the switch.
- Ensure proper grounding to prevent electrical shock.
- Verify all wiring connections are secure and correct according to the wiring diagram.
- Do not operate the switch if it is damaged or malfunctioning.
- This product is designed for L+N 220-240V 50-60Hz systems. Ensure your electrical system matches these specifications.
3. Product Overview
The TXATS-125/2P-EW is a compact and intelligent automatic transfer switch. It features both manual and automatic operation modes, along with smart control capabilities via the eWeLink app.

Figure 3.1: Overview of the TAXNELE ATS switch and its eWeLink app interface.

Figure 3.2: Diagram illustrating the two control methods: manual handle and eWeLink app remote control.

Figure 3.3: Detailed view of the manual/auto switch, power indicators (A and B), and terminal labels for Normal Power A and Reserve Power B.
4. Specifications
| Feature | Specification |
|---|---|
| Model | TXATS-125/2P-EW |
| Brand Name | TAXNELE |
| Type | Mini |
| Rated Working Current | 125A |
| Rated Working Voltage | 220VAC |
| Insulation Voltage | 690VAC |
| Rated Impulse Withstand Voltage | 8KV |
| Tse Class | PC |
| Frequency | 50/60Hz |
| Standard | IEC60947-6-1 |
| App Control | eWeLink |
| Switching Time | <50ms |
| Action Time | <50ms |
| Rated Supply Voltage Us | AC (L N) 220V-230V 50Hz-60Hz |
| Working Condition | 85% Us~110% Us |
| Origin | Mainland China |
| Certification | CE |

Figure 4.1: Dimensions of the TXATS-125/2P-EW Automatic Transfer Switch.
5. Installation
The TXATS-125/2P-EW is designed for easy installation on a 35mm standard DIN rail, commonly found in household lighting distribution boxes.

Figure 5.1: The ATS switch is designed for 35mm standard rail installation, suitable for household lighting distribution boxes.
5.1 Wiring Diagram
Refer to the following wiring diagram for correct connection of the normal power, backup power, and load. Ensure all connections are tight and secure.

Figure 5.2: Detailed wiring diagram for the 125A 2P ATS switch, showing common power input, backup power input, load output, common control lines, and backup control line.
- Common Power Input (Priority Power A): Connect your primary power source to the terminals labeled 'PRIORITY POWER A'.
- Backup Power Input (Reserve Power B): Connect your secondary/backup power source to the terminals labeled 'RESERVE POWER B'.
- Load Output: Connect your electrical load to the 'Output' terminals.
- Control Lines: Connect common control lines and backup control lines as indicated in the diagram for proper functionality.
6. WiFi Connection Setup
To utilize the smart control features, connect your ATS switch to the eWeLink app.
- Ensure the ATS switch is powered on and the manual/auto switch is set to 'Auto' mode.
- On the ATS device, press the reset key for 5 seconds. The WiFi indicator light should start blinking, indicating pairing mode.
- Open the eWeLink app on your smartphone.
- Follow the in-app instructions to add a new device. The app should detect the ATS switch.
- Once detected, select the device and complete the pairing process by entering your WiFi network details.

Figure 6.1: Instructions for connecting the device to WiFi: switch to Source A (Normal Power) and press the reset key for 5 seconds to enter pairing mode.
Video 6.1: Demonstration of WiFi pairing and automatic/manual power switching functionality.
7. Operating Instructions
7.1 Automatic Transfer Mode
When the switch is set to 'Auto' mode, the device will automatically detect the status of the normal power source. If the normal power is lost or becomes abnormal, the ATS will switch to the reserve power source within 8 milliseconds, ensuring an uninterrupted power supply to your connected loads. When normal power is restored, the ATS will automatically switch back to the normal power source.

Figure 7.1: The ATS switch provides automatic switching to backup power within 8ms upon normal power loss, ensuring uninterrupted power.
7.2 Manual Control
The ATS switch features a manual handle that allows you to manually select between Normal Power A and Reserve Power B. This is useful for maintenance or specific operational requirements where automatic switching is not desired. To switch manually, rotate the handle to the desired power source (A or B).
7.3 eWeLink App Control
Once connected to the eWeLink app, you can remotely control the ATS switch. The app allows you to:
- Monitor the current power source (Normal or Reserve).
- Manually switch between Normal Power and Reserve Power.
- Set schedules for automatic switching at specific times.
- Receive notifications regarding power status changes.
8. Maintenance
Regular maintenance helps ensure the longevity and reliable operation of your ATS switch.
- Cleaning: Periodically clean the exterior of the switch with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Inspection: Annually inspect all wiring connections for tightness and signs of wear or corrosion. Check for any physical damage to the switch housing or components.
- Testing: Periodically test the automatic transfer function by temporarily disconnecting the normal power source to ensure the switch transfers to backup power correctly.
9. Troubleshooting
If you encounter issues with your ATS switch, refer to the following common problems and solutions:
- No Power Transfer:
- Check if both normal and backup power sources are active.
- Ensure the switch is in 'Auto' mode for automatic transfer.
- Verify all wiring connections are correct and secure.
- WiFi Connection Issues:
- Ensure your WiFi network is active and within range.
- Confirm the correct WiFi password was entered during setup.
- Try resetting the ATS switch (press reset key for 5 seconds) and re-pairing with the eWeLink app.
- Check if the eWeLink app is updated to the latest version.
- Indicators Not Lighting Up:
- Verify that power is supplied to the ATS switch.
- Check for loose connections or blown fuses in the power supply lines.
10. User Tips
- For critical applications, regularly test your backup power source and the ATS functionality to ensure readiness.
- Utilize the eWeLink app's scheduling feature to manage power sources efficiently, especially if you have varying power costs or specific times you prefer to use backup power.
- Consider installing a surge protector upstream of the ATS to protect both the switch and connected appliances from power surges.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the TAXNELE Official Store or your authorized dealer. Keep your purchase receipt as proof of purchase.