FDIK FDIK-S3

Contents

FDIK FDIK-S3 Pure Sine Wave Inverter

User Manual

1. Introduction

Thank you for purchasing the FDIK Pure Sine Wave Inverter. This inverter features an advanced circuit design, high-quality electronic components, and is engineered to output pure sine wave AC power. Its primary function is to convert DC voltage from a battery into AC voltage, making it suitable for various applications such as RVs and camping.

The FDIK-S3 model is available in 12V and 24V input options, providing a peak power of 4000W.

FDIK Pure Sine Wave Inverter, showing 2000W rated power and 4000W peak power.

Figure 1: FDIK Pure Sine Wave Inverter (2000W Rated, 4000W Peak)

2. Setup

2.1 Choosing the Right Battery

Selecting a suitable battery is crucial for optimal inverter performance. An undersized battery can limit the inverter's maximum output power.

If you already have a battery:

To determine the maximum power output of your battery, use the following formula:

Battery Maximum Output Power = U (Battery voltage) * I (Battery capacity) * 0.72

If you need to choose a battery:

To determine the required battery capacity for maximum inverter output, use this formula:

Battery Capacity = Inverter Maximum Output Power / U (Battery voltage) / 0.72

Refer to the table below for common battery capacities and their maximum output power:

Table showing maximum output power of common capacity batteries for 12V and 24V systems.

Figure 2: Maximum Output Power of Common Capacity Batteries

The inverter is compatible with various battery types, including LI (Lithium), SLD (Sealed Lead-Acid), GEL, FLD (Flooded Lead-Acid), and AGM (Absorbed Glass Mat) batteries.

Image showing battery types LI, SLD, GEL, FLD, AGM that the inverter can adapt to.

Figure 3: Compatible Battery Types

2.2 Installation Environment

For safety and optimal performance, install the inverter in a suitable location:

  • Dry: Install in a dry environment, away from water and humidity.
  • Cool: Recommended ambient temperature is -15°C to 30°C.
  • Good Ventilation: Ensure at least 5 cm of clearance around the device for proper heat dissipation.
  • Safety: Do not install near flammable gases or liquids.
  • Clean: Avoid environments full of dust and dirt.
Installation environment guidelines: Dry, Cool, Good ventilation, Safety, Clean.

Figure 4: Recommended Installation Environment

2.3 Connecting the Inverter to the Battery

Proper connection is vital to prevent damage and ensure safe operation:

  • Ensure the battery's output voltage matches the inverter's input voltage (e.g., a 12V battery for a 12V inverter). Incorrect voltage will either not provide enough power or damage the inverter.
  • Connect the red terminal of the inverter to the positive (+) pole of the battery.
  • Connect the black terminal of the inverter to the negative (-) pole of the battery.
  • DO NOT REVERSE THE CONNECTION, as this will damage the inverter.
  • Use the provided connecting wires. Due to large currents, using non-original or inadequate wires can be dangerous.
Inverter and battery connection diagram, showing positive (red) and negative (black) terminals connected to a battery, with cooling fans visible.

Figure 5: Inverter and Battery Connection Diagram

3. Operating Instructions

3.1 Front Panel Overview

The front panel provides the AC output and real-time status display:

  • AC Output Socket: Connect your AC appliances here.
  • LCD Display: Shows real-time working status, including input voltage (DC), output voltage (AC), power consumption (W), frequency (Hz), and battery level.
  • ON/OFF Switch: Powers the inverter on or off.
Close-up of the Smart Digital Display, showing input voltage (DC 24.6V), output voltage (AC 220V), power (1666W), frequency (50Hz), and battery level.

Figure 6: Smart Digital Display Details

3.2 Back Panel Overview

The back panel houses the DC input terminals and cooling fans:

  • Positive Electrode (Red): Connects to the positive terminal of the battery.
  • Negative Electrode (Black): Connects to the negative terminal of the battery.
  • Fan: Integrated cooling fans ensure efficient heat dissipation during operation.
Front and Back Panel diagrams of the inverter. Front panel shows AC output socket, LCD display, and ON/OFF switch. Back panel shows positive and negative electrodes and cooling fans.

Figure 7: Front and Back Panel Layout

4. Maintenance

  • Cooling System: The inverter features a smart fan cooling system designed for quiet and high-performance operation. Ensure the fans are not obstructed and the ventilation areas remain clear.
  • Cleaning: To maintain optimal performance and longevity, keep the inverter clean and free from dust and dirt. Regularly wipe down the exterior with a dry cloth.
  • Wiring: Always use the original or appropriately rated copper wire cables for connections. Using non-original or inadequate wiring can lead to overheating and potential hazards.
Image showing Product Parameters including dimensions, battery selection guidance, 93% conversion rate, smart fan cooling system, and top quality accessories (copper wire cable).

Figure 8: Smart Fan Cooling System and Quality Accessories

5. Troubleshooting and Safety Precautions

5.1 General Precautions

Improper installation or use can lead to danger. Please observe the following precautions:

  • Circuit Fire Prevention: When installing, consider fire prevention. Keep the inverter and battery away from combustible materials. The manufacturer is not responsible for fires caused by improper installation near combustibles.
  • Heated Surface: During prolonged high-power operation, the inverter housing can become hot (up to 50°C). Ensure sufficient ventilation space around the inverter and keep it away from heat-sensitive objects.
  • Explosion Hazard: Do not connect the battery and inverter in a confined space. Batteries can produce hydrogen gas during operation, which is flammable and can be ignited by sparks from wire connections.
  • Connecting the Battery: Always ensure the DC voltage of the battery matches the input DC voltage of the inverter. Incorrect voltage can prevent proper operation or damage the unit.
Precautions regarding circuit fire prevention, heated surface, explosion hazard, and connecting the battery.

Figure 9: Safety Precautions

5.2 Built-in Safety Protections

The FDIK-S3 inverter is equipped with 5 built-in safety protections to cover various load requirements and ensure safe operation:

  • Output Short Circuit Protection
  • Overload Protection
  • Over Current Protection
  • Under Voltage Protection
  • Over Voltage Protection (implied by Under Voltage and general inverter safety)
Image detailing 5 Built-in Safety Protections: Output Short Circuit Protection, Overload Protection, Over Current Protection, Under Voltage Protection.

Figure 10: Built-in Safety Protections

6. Specifications

Feature Specification
Model Number FDIK-S3
Type DC/AC Inverter (Pure Sine Wave)
Rated Power 2000W
Peak Power 4000W
Input Voltage Options 12V DC or 24V DC
Output Frequency 50Hz
Output Type SINGLE
Dimensions (L*W*H) 30*17*8.5 cm
Weight 3 KG
Conversion Rate 93%
Noise Level (Fan On) <60 dB
Certifications CE, RoHS
Comparison of FDIK-S3 inverter features (2000W real rated power, two-year warranty, sound <60 decibels) against other inverters.

Figure 11: FDIK-S3 Key Features

7. Warranty and Support

The FDIK-S3 Pure Sine Wave Inverter comes with a two-year warranty, ensuring reliability and peace of mind.

For detailed information and further assistance, please refer to the official user manual PDF available at: FDIK Inverter User Manual (PDF).

8. User Tips

  • Vehicle Compatibility: This inverter is suitable for use in vehicles like trucks or RVs, provided that the vehicle's battery system voltage (12V or 24V) matches the inverter model you have purchased. Always verify your vehicle's electrical system before connecting.
  • Application Scenarios: The inverter is versatile and can be used for emergency power, outdoor cooking setups, integration into RV systems, and as part of a solar power system.
Various application scenarios including Emergency Use, Outdoor cooking, RV System, and a detailed Solar System wiring diagram.

Figure 12: Typical Application Scenarios and Solar System Diagram

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.