This series of products is a single-output DC voltage regulator source, featuring an LED digital display. It can simultaneously display voltage, current, power, and output equivalent resistance. Both voltage and current are continuously adjustable.

1.1 Functional Features

  • LED digital display for simple and intuitive display of power transmission.
  • Displays voltage, current, power, and output equivalent resistance.
  • Steady voltage and steady current automatic switch.
  • Equipped with an output control switch for more flexible control.
  • Protection features: overvoltage, overcurrent, overpower, over temperature, short circuit protection.
  • Convenient and fast operation interface.
  • Temperature-controlled fan speed for low noise and extended fan life.
  • Voltage and current values can be preset in the output-off state for easy operation.

2. Safety Instructions

This section contains important safety instructions that must be followed for operating the power supply and storage environment. To ensure your personal safety, read the following instructions carefully before operating to ensure that the power supply is in the best working environment.

2.1 General Safety Guide

  • Do not place heavy objects on the casing.
  • Avoid serious impact or improper disposal.
  • Measures to prevent electrostatic discharge should be taken when connecting the instrument.
  • Do not block or isolate the fan vents.
  • Do not open the machine unless you are a professional.

2.2 Power Supply Safety

  • AC input voltage: 220V ± 10%, 50Hz (110V input or 100V / 220V manual switch).
  • The ground wire of the power cord should be connected to the ground end to avoid electric shock.

2.3 Fuse Safety

  • Ensure the correct fuse model before boot.
  • To prevent fire, replace the fuse complying with the model and rating.
  • Cut off the power supply before replacing the fuse to eliminate the risk of dangerous wire damage.

2.4 Cleaning Instructions

  • Cut off the power supply before cleaning.
  • Use mild detergent and a water-wet soft cloth; do not directly spray detergent.
  • Do not use chemical or cleaning agent products containing grinding agents such as benzene, toluene, xylene, and acetone.

2.5 Operating and Storage Environment

Parameter Operating Environment Storage Environment
Location Indoor, avoid direct sun exposure and dust, no strong magnetic fields. Indoor storage
Relative Humidity <80% <70%
Altitude <2,000 m N/A
Temperature 5°C to 40°C 0°C to 70°C

3. Product Overview

3.1 Front Panel

The front panel provides controls and displays for voltage, current, and power output.

Front panel diagram of the DC power supply showing controls and displays.

Image: Front panel diagram with labeled controls and displays.

  1. Voltage Display: Shows current output voltage (V) when ON, or set voltage when OFF.
  2. Current Display: Shows current output current (A) when ON, or set current when OFF.
  3. Power Display: Shows current output power (W) when ON, or "0.000" when OFF.
  4. Power Supply Load Equivalent Resistance Display: Shows current load equivalent resistance (R). Display range: 0.000R ~ 9999R. Displays "----" beyond range.
  5. Output ON / OFF Key: Controls power output. Green indicates ON, red indicates OFF.
  6. Power Switch: Turns the power supply ON or OFF.
  7. Transmission, Negative Electrode: Power output negative (-) pole. Output current range: 0~10A. Models above 2400W do not have this port.
  8. Output Positive Electrode: Power output positive (+) pole. Output current range: 0~10A. Models above 2400W do not have this port.
  9. Ground Terminal: Safe ground wire terminal, connected to the power supply shell. Models above 2400W do not have this port.
  10. OT Indicator: Lights up when the power supply is under overtemperature protection.
  11. C.C. Steady Current Indicator: Lights up when the power supply is in steady current working state.
  12. Current Fine Adjustment: Fine-tunes the current value for current stability, used with the coarse adjustment knob.
  13. OP Indicator: Lights up when the power supply is under overpower protection.
  14. Current Rough Adjustment: Roughly adjusts the current value for current stability, used with the fine adjustment knob.
  15. OC Indicator Light: Lights up when the power supply is in overcurrent protection state.
  16. C.V. Pressure Stabilization Indicator: Lights up when the power supply is in voltage stabilization state.
  17. Voltage Fine Adjustment: Fine-tunes the voltage value for voltage stability, used with the coarse adjustment knob.
  18. OV Indicator Light: Lights up when the power supply is in overvoltage protection state.
  19. Voltage Rough Adjustment: Roughly adjusts the voltage value for voltage stability, used with the fine adjustment knob.

3.2 Rear Panel

The rear panel includes input power connections, fan vents, and communication interfaces.

Rear panel diagram of the DC power supply showing input, output, and communication ports.

Image: Rear panel diagram with labeled ports and fan.

  1. SENSE Negative Input: Distal sampling point of negative power output voltage (not available by default).
  2. SENSE Input Positive Electrode: Distal sampling point of positive electrode of power output voltage (not available by default).
  3. Output Positive Electrode: Power supply output positive (+) pole. Output current range: 0~maximum rated value.
  4. Output Negative Pole: Power output negative (-) pole. Output current range: 0~maximum rated value.
  5. Heat Dissipation Fan Vent: For power air cooling. Fan speed is intelligently adjusted based on power consumption to reduce noise and prolong fan life.
  6. Ground Terminal: Ground wire terminal, connected with the power shell.
  7. Fuse Seat: Equipped with a power fuse. Can be replaced by prying open with a screwdriver. Note: 2400W (inclusive) and above models do not have a fuse seat, they have a built-in circuit breaker.
  8. Power Input Socket: AC input port. For 2400W (inclusive) and above models, this leads to a cable line connected to the input AC.
  9. Input Power Switch: AC 110V / 220V input switch (default without this switch).
  10. Communication Interface: RS 232 / RS 485 / USB and other interfaces, which can communicate with the control CPU of the power supply and read the output value (default no communication interface).

4. Setup

4.1 First Use and Power Connection

  1. Input Power Supply Requirements: Refer to the specifications section for input power supply details.
  2. Check the Fuse: Ensure the fuse is correctly installed.
  3. Connect the Instrument Power Cord: Connect the instrument to the AC power supply using the provided power cord. For models above 2400W, the cable is directly connected from the power supply to the AC power supply.

WARNING: To avoid electric shock, verify that the instrument is correctly grounded.

4.2 Power-on Inspection

  1. Press the power switch key on the front panel to turn on the power. The backlight of the ON/OFF button will be red, indicating the power output is off.
  2. Press the ON/OFF button again. The backlight will turn green, indicating the power is on for output.

Tip: If the machine is turned on again after shutdown, please ensure that the interval between startups is more than 5 seconds.

4.3 Output Check

Output check ensures that the instrument responds correctly to front panel operation and outputs the rating. This includes checking voltage output when the channel is empty and current output when short-circuited.

4.3.1 Output Switch

  • To turn on the power output, press the ON / OFF key. The backlight turns green.
  • Pressing the key again will close the output and turn the backlight red.

4.3.2 Check Voltage Output

  1. When the instrument is in no load, turn on the power key and confirm that the current setting value of the current knob is not 0.
  2. Press the "ON / OFF" key to open the output. After the backlight becomes green, the channel is in the stabilized output state (C.V light on). Check whether the voltage can be adjusted from 0 to the maximum rating value.

4.3.3 Current Output Check

  1. Turn on the power button.
  2. Adjust the voltage knob so that the power output voltage value is any value in 3-5V. Press the "ON / OFF" key again to disconnect the output.
  3. Use a wire to short-connect the front panel output terminal.
  4. Press the "ON / OFF" key to open the output. When the backlight becomes green, the channel is in the steady flow output state (C.C. light on). Check whether the current can be adjusted from 0 to the maximum rating.

5. Operating Instructions

The power supply provides two power output modes: Voltage Control Output (CV) and Steady Flow Output (CC).

5.1 Pressure Output (CV Mode)

In CV mode, the output voltage is directly controlled by two knobs (coarse and fine adjustment) for voltage setting. For example, to set the voltage to 16V and current to maximum rating with an 8 Ω / 300W load:

Wiring diagram for connecting load to the power supply output terminals.

Image: Wiring diagram for load connection.

  1. Turn on the power supply: Press the power supply key to start the instrument.
  2. Voltage setting: Adjust the voltage coarse and fine adjustment knobs to set the voltage value to 16V.
  3. Current setting: Adjust the current coarse and fine adjustment knobs to stabilize the current value to the maximum rated value.
  4. Connect the output lead: Connect the instrument output terminal to the load as shown in the figure above.
  5. Open the output: Press the "ON / OFF" key (backlight bright green). The instrument will work in stable voltage control output mode.

Tip: In CV mode, if the output current exceeds the set value due to load change, the instrument will switch to CC mode, and the output voltage will decrease proportionally. Increase the current setting value to restore CV output.

5.2 Steady Current Output (CC Mode)

In CC mode, the output current is controlled by two knobs (coarse and fine adjustment) for current setting. For example, to set the voltage to 16V and current to 5A (MY-305) with a 1 Ω / 300W load:

  1. Connect the output lead: Connect the output terminal of the instrument to the load as shown in the wiring diagram above.
  2. Turn on the power supply: Press the power supply key to start the instrument.
  3. Voltage setting: Adjust the voltage coarse and fine adjustment knobs to set the voltage value to 16V.
  4. Current setting: Adjust the current coarse and fine adjustment knobs to stabilize the current value to the maximum rated value.
  5. Open the output: Press the "ON / OFF" key (backlight bright green). The instrument will work in steady flow output mode.

WARNING: Incorrect connections may cause damage to this product or the equipment connected to the product.

Tip: In CC mode, if the output voltage exceeds the set value due to load change, the instrument will switch to CV mode, and the output current will decrease proportionally. Increase the voltage setting value to restore CC output.

6. Maintenance

6.1 Regular Inspection

To ensure the product operates in its best condition, perform regular inspections:

  • Check whether the power supply device power input outlet shows signs of burnout.
  • Check the power output terminals for loosening.

6.2 Fuse Replacement

Follow these steps to replace the fuse:

  1. Remove the power cord.
  2. Carefully pry open the fuse box with a small screwdriver.
  3. Replace the fuse with one that complies with the model and rating.
Diagram showing how to remove and replace the fuse.

Image: Fuse replacement diagram (Graph 1: removing fuse box, Graph 2: replacing fuse).

Fuse Specifications:

  • Power of 1200W model:
    • 220V: F 10A / 250V
    • 110V: F 20A / 250V
  • 1200W < Power < 2400W model:
    • 220V: F 20A / 250V

Note: Power 2400W models do not have a fuse; they have a built-in circuit breaker.

7. Specifications

7.1 Rated DC Output (0℃~40℃)

  • Voltage stability: ≤2%
  • Current stability: ≤0.5%
  • Load stability: ≤0.5%
  • Ripple and noise: ≤1% (RMS)

7.2 Resolution

Parameter Resolution
Voltage resolution <100V: 10mV, ≥100V: 100mV
Current resolution <100A: 10mA, ≥100A: 100mA
Power resolution <10W: 1mW, ≥10W: 10mW, ≥100W: 0.1W, ≥1000W: 1W
Load equivalent resistance display resolution <10R: 1mR, ≥10R: 10mR, ≥100R: 0.1R, ≥1000R: 1R

7.3 Preset Accuracy

  • Output voltage preset accuracy: ±0.1V
  • Output constant current preset accuracy: ±0.1A

7.4 Environmental Conditions

  • Altitude: ≤2000m
  • Operating Ambient temperature: 5℃~ 40℃
  • Operating Relative humidity: <80%
  • Storage Ambient temperature: -20℃~ 80℃
  • Storage Relative humidity: ≤80%

7.5 Power Input

  • AC220V±10%, 50Hz (or AC110V input or AC100V/220V manual switching)
  • Reminder: 110V input or 220V input can be fixed within 900W; 110V input is not supported above 1000W.

7.6 Physical Dimensions and Weight

Naked Machine Size:

  • <2400W model: 330(D) x 250(W) x 155(H) mm
  • 2400W model: 410(D) x 250(W) x 155(H) mm

Packaging Dimensions:

  • <2400W model: 420(D) x 310(W) x 220(H) mm
  • 2400W model: 497(D) x 310(W) x 220(H) mm

Net Weight:

Type Net Weight
<2400W About 5Kg
≥2400W About 7.5Kg

8. Troubleshooting

This section provides general guidance for common issues. For detailed troubleshooting, please refer to the full user manual (PDF).

  • No Power: Ensure the power cord is securely connected and the power switch is ON. Check the fuse (for models <2400W) or circuit breaker (for models ≥2400W).
  • No Output: Ensure the output ON/OFF key is pressed and its backlight is green. Check for any active protection indicators (OT, OP, OC).
  • Voltage/Current Not Stable: Verify load connections are secure. Ensure the operating environment meets specifications (temperature, humidity).
  • Over-temperature (OT indicator ON): Ensure fan vents are not blocked and the unit has adequate ventilation. Reduce load if necessary.
  • Overpower (OP indicator ON): Reduce the output power demand from the load.
  • Overcurrent (OC indicator ON): Reduce the output current demand from the load. Check for short circuits in the load.

9. User Tips

  • Always ensure proper ventilation around the power supply to prevent overheating and ensure optimal performance.
  • Before connecting or disconnecting any load, ensure the power output is turned OFF to prevent accidental damage to the power supply or the connected device.
  • Regularly check the output terminals for secure connections to avoid intermittent operation or arcing.
  • When adjusting voltage or current, make small, incremental changes, especially when working with sensitive circuits.

10. Warranty and Support

Thank you for choosing this power supply. Our company strictly implements the national three guarantees policy.

10.1 Warranty Policy

If the product experiences a quality problem not caused by human factors, you can handle it with the invoice and voucher for repair or replacement. Beyond the warranty period, only charges for spare parts replacement will apply.

Please properly package and deliver the products for repair. The company will not be responsible for any damage or loss during the delivery process.

The warranty period is 12 months for free warranty service (excluding accessories).

10.2 Conditions Not Covered by Warranty Services

  • Beyond the validity period of the three guarantees.
  • Altering the three guarantees' certificate without authorization.
  • Failure to use, maintain, and keep the product according to the requirements of the use instructions.
  • Product damage caused by natural disasters, power grid failure, or other irresistible factors.
  • Attachments not covered by the warranty.
  • The product model or number on the three guarantees certificate does not comply with the physical goods.

For detailed warranty information and to register your product, please refer to the official user manual PDF: User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.