1. Product Overview
This manual provides detailed instructions for the installation, operation, and maintenance of the GEBERIT Model 240.637.00.1 concealed water tank flush valve. This product is designed for use in concealed cisterns, providing efficient water flushing for toilets.

This image shows the complete flush valve assembly, featuring the dual flush levers for water volume control.
This video illustrates how to adjust the water volume settings and demonstrates the flush valve's operation within a concealed cistern setup.
2. Specifications
| Attribute | Value |
|---|---|
| Model Number | 240.637.00.1 |
| Item Number | 240.637.00.1 |
| Producer | GEBERIT |
| Material | Plastic |
| Type | Other (Flush Valve) |
| Function | Water Flushing |
| Flush Valve Type | Hand Control |
| Design Style | Modern |
| Place of Origin | Shanghai, China (Mainland China) |
| High-concerned chemical | None |
| Package Length | 30 cm |
| Package Width | 25 cm |
| Package Height | 25 cm |
| Package Weight | 8.0 kg |
3. Safety Information
- Always turn off the water supply to the cistern before attempting any installation, maintenance, or repair.
- Wear appropriate personal protective equipment (PPE) such as gloves and eye protection.
- Ensure all connections are secure to prevent leaks.
- If you are unsure about any step, consult a qualified plumber.
- Keep small parts out of reach of children.
4. Installation
The GEBERIT concealed flush valve is designed for integration into a concealed cistern system. Follow these general steps for installation. Specific cistern models may have slight variations.
4.1 Component Identification

Familiarize yourself with the main body, flush levers (for dual flush), and the sealing gasket before assembly.
4.2 Assembly and Placement
- Ensure the cistern is clean and free of debris.
- Place the main body of the flush valve into the cistern's outlet opening.
- Secure the flush valve from underneath the cistern using the provided nut, ensuring the sealing gasket is correctly positioned to prevent leaks.
- Attach the flush levers to the top of the valve mechanism. The design supports dual flush functionality.

This image shows the flush valve with an extended rod, which connects to the external flush button mechanism.

Depending on your toilet button switch accessories, you may use either the long or short rod provided for connection.
- Connect the appropriate flush rod (long or short, depending on your toilet's button mechanism) to the flush valve and the external flush button.
- Once installed, slowly turn on the water supply to the cistern and check for any leaks.
5. Operation
The GEBERIT flush valve provides a reliable water flushing function for your toilet. It typically operates with a dual-flush mechanism, allowing for water-saving options.
5.1 Flushing
- Full Flush: Press the larger button or the full-flush side of the lever for a complete flush.
- Half Flush: Press the smaller button or the half-flush side of the lever for a reduced water flush, ideal for liquid waste to conserve water.
5.2 Water Volume Adjustment
The flush valve allows for adjustment of the water volume for both full and half flushes. This is typically done via a dial or lever on the valve body.

Rotate the blue dial on the side of the valve body to increase or decrease the water volume per flush. Refer to Video 1 for a visual guide.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your flush valve.
- Cleaning: Periodically clean the flush valve components, especially the sealing gasket and the flush mechanism, to prevent mineral buildup and ensure smooth operation. Use mild soap and water; avoid harsh chemicals.
- Inspection: Annually inspect the sealing gasket for wear or damage. Replace if necessary to prevent leaks. Check that the flush levers and rods move freely without obstruction.
- Water Supply: Ensure the water supply to the cistern is clean and free of sediment, which can clog the valve.
7. Troubleshooting
Here are some common issues and their potential solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Toilet runs continuously | Worn or misaligned sealing gasket; debris under the gasket; flush mechanism stuck open. | Turn off water supply. Inspect and clean the sealing gasket. Replace if worn. Ensure flush mechanism moves freely. |
| Weak or incomplete flush | Water level too low; flush volume set too low; partial obstruction in the outlet. | Check water level in cistern. Adjust water volume settings (refer to Section 5.2). Inspect for obstructions. |
| Flush button/lever is stiff | Misaligned flush rod; debris in the mechanism; worn components. | Check alignment of flush rod. Clean the mechanism. If problem persists, components may need replacement. |
| Water leaks from cistern | Loose connections; damaged cistern; faulty fill valve (not flush valve). | Tighten all connections. Inspect cistern for cracks. If fill valve is leaking, it may need separate attention. |
8. User Tips
- When adjusting the water volume, make small changes and test the flush to find the optimal balance between water conservation and effective flushing.
- If you notice any unusual noises during flushing or filling, it's a good indicator to inspect the valve for potential issues before they escalate.
- For hard water areas, consider more frequent cleaning of the flush valve components to prevent limescale buildup.
9. Warranty and Support
9.1 Warranty
This product is provided without an explicit warranty. Please refer to your purchase agreement for any implied warranties or return policies.
9.2 Technical Support
For technical assistance or inquiries regarding the GEBERIT Model 240.637.00.1 flush valve, please contact the seller directly using the following methods: