RuoShui 8045-II

Contents

RuoShui 8045-II True RMS Digital Desktop Multimeter

User Manual

1. Introduction

The RuoShui 8045-II is a high-precision, True RMS digital desktop multimeter designed for a wide range of electrical measurements. With its strong stability and 20000 counts display, it is an ideal tool for laboratories, factories, radio hobbyists, and general household use. This manual provides detailed instructions for the safe and effective operation of your multimeter.

RuoShui 8045-II Benchtop Digital Multimeter with key features
Figure 1: RuoShui 8045-II Multimeter highlighting features like Relative value, Max/Min, Backlit display, Data hold, Low pressure tips, and VA reverse display.

2. Package Contents

Please check the package carefully to ensure all items are present and undamaged:

  • Packing box
  • RuoShui 8045-II Digital Desktop Multimeter
  • Power cable
  • Adapters (if applicable to your region)
  • Test leads (red and black)
  • Product Manual (this document)
Contents of the RuoShui 8045-II multimeter package
Figure 2: Included accessories: (1) Packing boxes, (2) Desktop multimeter, (3) Power cable, (4) Adapters, (5) Test leads, (6) Product Manual.

3. Product Overview

Familiarize yourself with the components and controls of your RuoShui 8045-II multimeter:

Front and rear panel diagram of RuoShui 8045-II multimeter with numbered parts
Figure 3: Front and rear panel components of the multimeter.
  1. LCD display: Shows measurement readings and symbols. Features VA reverse display, 4 1/2 digits of precision, and a maximum reading of 19999.
  2. Screen switch button: Toggles the display backlight.
  3. HOLD button: Freezes the current reading on the display.
  4. REL (Relative value) button: Measures the difference between a stored reference value and the current reading.
  5. AC+DC selector switch: Toggles between AC and DC measurement modes for certain functions.
  6. MAX/MIN button: Records and displays the maximum and minimum values during a measurement session.
  7. Range knob: Selects the desired measurement function and range. The knob has a clear range, color distinction, and a strong sense of pause when turned.
  8. COM (Common) input terminal: For connecting the black test lead.
  9. V/Ω/Hz input terminal: For voltage, resistance, frequency, and capacitance measurements.
  10. 200mA input terminal: For current measurements up to 200mA.
  11. 2/20A input terminal: For high current measurements up to 20A.
  12. Voltage transfer switch: Allows selection between 110V and 220V AC power input.
  13. Power switch: Turns the multimeter ON/OFF.
  14. Fuse box: Houses the protective fuse.
  15. Power outlet: For connecting the power cable.
Detailed views of the multimeter's bracket and fuse box design
Figure 4: The instrument stand can be rotated for horizontal placement, support, or hand-held use. The power jack conforms to international safety standards and includes a fuse for protection.

4. Specifications

Parameter Value
Model Number8045-II
Display TypeDigital Display (20000 Counts)
Operating ModeAuto Range
Operating Temperature0 - 40 ℃
Dimensions245*220*82mm
DIY SuppliesElectrical
PowerAC 110V/220V, 50-60Hz, 20VA
Fuse200mA/250V

Measurement Ranges and Accuracy:

Table of DC Voltage, AC Voltage True RMS, and DC Current specifications
Figure 5: Detailed specifications for DC Voltage, AC Voltage (True RMS), and DC Current measurements.
Measurement Range Accuracy Resolution
DC Voltage200mV±(0.05%+5)10µV
2V100µV
20V±(0.1%+5)1mV
200V10mV
1000V±(0.1%+5)100mV
AC Voltage (True RMS)200mV40Hz~1KHz: ±(0.7%+30)
1KHz~10KHz: ±(2%+30)
10KHz~20KHz: ±(3%+60)
20KHz~50KHz: ±(10%+250)
10µV
2V40Hz~1KHz: ±(0.5%+30)
1KHz~10KHz: ±(2%+30)
100µV
20V40Hz~1KHz: ±(0.5%+30)1mV
200V40Hz~1KHz: ±(0.5%+30)
1KHz~5KHz: ±(2%+30)
10mV
750V40Hz~200Hz: ±(0.8%+10)
200Hz~400Hz: ±(1.2%+80)
100mV
DC Current200µA±(0.35%+10)0.01µA
2mA0.1µA
20mA1µA
2A±(0.8%+10)100µA
20A±(2.0%+15)1mA
Table of AC Current True RMS, Resistance, Capacitance, and Frequency specifications
Figure 6: Detailed specifications for AC Current (True RMS), Resistance, Capacitance, and Frequency measurements.
Measurement Range Accuracy Resolution
AC Current (True RMS)20mA±(0.8%+80)1µA
200mA±(0.8%+80)10µA
2A±(0.8%+80)100µA
20A±(2.5%+35)1mA
Resistance200Ω±(0.5%+30)0.01Ω
2kΩ0.1Ω
20kΩ±(0.5%+40)1Ω
200kΩ10Ω
2MΩ±(0.6%+50)100Ω
20MΩ1KΩ
Capacitance10nF±(3.5%+20)1pF
100nF10pF
1µF100pF
10µF1nF
100µF±(5%+30)10nF
1mF100nF
2mF1µF
Frequency20Hz~200kHz±(0.1%+3)0.01Hz~0.1kHz
200kHz~2MHz0.1kHz~0.001MHz
2MHz~20MHz0.001MHz~0.01MHz

5. Setup

  1. Power Connection:
    • Ensure the multimeter's power switch (13) is in the OFF position.
    • Locate the Voltage transfer switch (12) on the rear panel. Set it to match your local AC power supply (110V or 220V).
    • Connect the provided power cable to the power outlet (15) on the rear of the multimeter and then to a suitable AC power source.
  2. Test Lead Connection:
    • Insert the black test lead into the COM (Common) input terminal (8).
    • For most measurements (voltage, resistance, frequency, capacitance), insert the red test lead into the V/Ω/Hz input terminal (9).
    • For current measurements, insert the red test lead into the appropriate current input terminal (10 for 200mA, 11 for 2/20A). Always ensure the test leads are connected to the correct terminals for the measurement you intend to perform to prevent damage to the multimeter or circuit.
  3. Power On: Flip the power switch (13) to the ON position. The LCD display should light up.

6. Operating Instructions

This section outlines how to perform various measurements using your RuoShui 8045-II multimeter. Always ensure the multimeter is correctly set up and test leads are connected to the appropriate terminals before making any measurements.

General Measurement Procedure:

  1. Connect the test leads as described in the Setup section.
  2. Turn the Range knob (7) to the desired measurement function (e.g., Ω for resistance, V for voltage, A for current, F for capacitance, Hz for frequency, hFE for transistor testing).
  3. If the function has multiple ranges (e.g., 200mV, 2V, 20V for DC Voltage), the multimeter will typically auto-range. If not, select an appropriate range higher than the expected value.
  4. Connect the test probes to the circuit or component you wish to measure.
  5. Read the value on the LCD display (1).
  6. After measurement, disconnect the test probes from the circuit, then turn the Range knob to the OFF position and power off the multimeter.

Specific Measurement Examples:

Video 1: Demonstration of resistance, diode, and capacitance measurements using the RuoShui 8045-II multimeter.

Resistance Measurement:

  • Turn the Range knob to the 'Ω' (Ohms) section.
  • Connect the test probes across the component to measure its resistance.
  • The display will show the resistance value in Ohms (Ω), kilo-Ohms (kΩ), or Mega-Ohms (MΩ).

Diode Measurement:

  • Turn the Range knob to the diode symbol (▶|).
  • Connect the red probe to the anode and the black probe to the cathode of the diode.
  • The display will show the forward voltage drop. Reverse the probes; an open circuit (OL) reading indicates a good diode.

Capacitance Measurement:

  • Turn the Range knob to the 'F' (Farad) section.
  • Connect the test probes across the capacitor.
  • The display will show the capacitance value in nano-Farads (nF), micro-Farads (µF), or milli-Farads (mF).

Voltage (AC/DC) Measurement:

  • Turn the Range knob to the 'V' (Voltage) section.
  • Use the AC+DC button (5) to select between AC (~) or DC (---) voltage.
  • Connect the test probes in parallel with the circuit or component to measure voltage.

Current (AC/DC) Measurement:

  • Turn the Range knob to the 'A' (Ampere) section.
  • Ensure the red test lead is connected to the appropriate current input terminal (10 or 11).
  • Use the AC+DC button (5) to select between AC (~) or DC (---) current.
  • Connect the multimeter in series with the circuit to measure current.

Frequency Measurement:

  • Turn the Range knob to the 'Hz' (Hertz) section.
  • Connect the test probes to the circuit where you want to measure frequency.

Transistor (hFE) Measurement:

  • Turn the Range knob to the 'hFE' section.
  • Insert the transistor leads into the corresponding hFE sockets on the multimeter.

7. Maintenance

General Care:

  • Keep the multimeter clean and dry. Wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents.
  • Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures.
  • Avoid dropping the multimeter or subjecting it to strong impacts.

Fuse Replacement:

If the multimeter fails to measure current or shows incorrect readings in current modes, the fuse may need replacement. The fuse box (14) is located on the rear panel.

  1. Ensure the multimeter is powered OFF and disconnected from the AC power source.
  2. Carefully open the fuse box cover.
  3. Remove the old fuse.
  4. Replace it with a new fuse of the specified type and rating: 200mA/250V. Using an incorrect fuse can damage the multimeter or pose a safety hazard.
  5. Close the fuse box cover securely.

8. Troubleshooting

Problem Possible Cause Solution
Multimeter does not power on No AC power, power cable loose, power switch off, incorrect voltage selection. Check AC power source. Ensure power cable is securely connected. Verify power switch is ON. Check Voltage transfer switch (110V/220V) setting.
No reading or "OL" (Overload) displayed Incorrect range selected, open circuit, test leads not connected properly, component out of range. Select a higher range or auto-range. Check for breaks in the circuit. Ensure test leads are firmly connected. Verify component is within measurement limits.
Incorrect current reading Blown fuse, incorrect current input terminal used, multimeter not in series. Check and replace fuse if necessary. Ensure red test lead is in the correct 'A' or 'mA' terminal. Connect multimeter in series with the circuit.
Display is dim or flickering Low power supply voltage. Ensure stable AC power supply.

9. User Tips

  • Always start with the highest range when measuring an unknown value to prevent overloading the multimeter.
  • Ensure proper polarity when measuring DC voltage or current.
  • When measuring resistance, ensure the circuit is de-energized to avoid inaccurate readings or damage.
  • For precise capacitance measurements, ensure the capacitor is fully discharged before connecting the multimeter.
  • Utilize the 'HOLD' function to freeze a reading on the display, which is useful when measuring in hard-to-reach areas.
  • The 'MAX/MIN' function is excellent for capturing transient peaks or monitoring fluctuations over time.

10. Warranty and Support

RuoShui products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official RuoShui website. Please retain your proof of purchase for warranty claims.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.