1. Introduction
The RuoShui 8045-II is a high-precision, True RMS digital desktop multimeter designed for a wide range of electrical measurements. With its strong stability and 20000 counts display, it is an ideal tool for laboratories, factories, radio hobbyists, and general household use. This manual provides detailed instructions for the safe and effective operation of your multimeter.
2. Package Contents
Please check the package carefully to ensure all items are present and undamaged:
- Packing box
- RuoShui 8045-II Digital Desktop Multimeter
- Power cable
- Adapters (if applicable to your region)
- Test leads (red and black)
- Product Manual (this document)
3. Product Overview
Familiarize yourself with the components and controls of your RuoShui 8045-II multimeter:
- LCD display: Shows measurement readings and symbols. Features VA reverse display, 4 1/2 digits of precision, and a maximum reading of 19999.
- Screen switch button: Toggles the display backlight.
- HOLD button: Freezes the current reading on the display.
- REL (Relative value) button: Measures the difference between a stored reference value and the current reading.
- AC+DC selector switch: Toggles between AC and DC measurement modes for certain functions.
- MAX/MIN button: Records and displays the maximum and minimum values during a measurement session.
- Range knob: Selects the desired measurement function and range. The knob has a clear range, color distinction, and a strong sense of pause when turned.
- COM (Common) input terminal: For connecting the black test lead.
- V/Ω/Hz input terminal: For voltage, resistance, frequency, and capacitance measurements.
- 200mA input terminal: For current measurements up to 200mA.
- 2/20A input terminal: For high current measurements up to 20A.
- Voltage transfer switch: Allows selection between 110V and 220V AC power input.
- Power switch: Turns the multimeter ON/OFF.
- Fuse box: Houses the protective fuse.
- Power outlet: For connecting the power cable.
4. Specifications
| Parameter | Value |
|---|---|
| Model Number | 8045-II |
| Display Type | Digital Display (20000 Counts) |
| Operating Mode | Auto Range |
| Operating Temperature | 0 - 40 ℃ |
| Dimensions | 245*220*82mm |
| DIY Supplies | Electrical |
| Power | AC 110V/220V, 50-60Hz, 20VA |
| Fuse | 200mA/250V |
Measurement Ranges and Accuracy:
| Measurement | Range | Accuracy | Resolution |
|---|---|---|---|
| DC Voltage | 200mV | ±(0.05%+5) | 10µV |
| 2V | 100µV | ||
| 20V | ±(0.1%+5) | 1mV | |
| 200V | 10mV | ||
| 1000V | ±(0.1%+5) | 100mV | |
| AC Voltage (True RMS) | 200mV | 40Hz~1KHz: ±(0.7%+30) 1KHz~10KHz: ±(2%+30) 10KHz~20KHz: ±(3%+60) 20KHz~50KHz: ±(10%+250) | 10µV |
| 2V | 40Hz~1KHz: ±(0.5%+30) 1KHz~10KHz: ±(2%+30) | 100µV | |
| 20V | 40Hz~1KHz: ±(0.5%+30) | 1mV | |
| 200V | 40Hz~1KHz: ±(0.5%+30) 1KHz~5KHz: ±(2%+30) | 10mV | |
| 750V | 40Hz~200Hz: ±(0.8%+10) 200Hz~400Hz: ±(1.2%+80) | 100mV | |
| DC Current | 200µA | ±(0.35%+10) | 0.01µA |
| 2mA | 0.1µA | ||
| 20mA | 1µA | ||
| 2A | ±(0.8%+10) | 100µA | |
| 20A | ±(2.0%+15) | 1mA |
| Measurement | Range | Accuracy | Resolution |
|---|---|---|---|
| AC Current (True RMS) | 20mA | ±(0.8%+80) | 1µA |
| 200mA | ±(0.8%+80) | 10µA | |
| 2A | ±(0.8%+80) | 100µA | |
| 20A | ±(2.5%+35) | 1mA | |
| Resistance | 200Ω | ±(0.5%+30) | 0.01Ω |
| 2kΩ | 0.1Ω | ||
| 20kΩ | ±(0.5%+40) | 1Ω | |
| 200kΩ | 10Ω | ||
| 2MΩ | ±(0.6%+50) | 100Ω | |
| 20MΩ | 1KΩ | ||
| Capacitance | 10nF | ±(3.5%+20) | 1pF |
| 100nF | 10pF | ||
| 1µF | 100pF | ||
| 10µF | 1nF | ||
| 100µF | ±(5%+30) | 10nF | |
| 1mF | 100nF | ||
| 2mF | 1µF | ||
| Frequency | 20Hz~200kHz | ±(0.1%+3) | 0.01Hz~0.1kHz |
| 200kHz~2MHz | 0.1kHz~0.001MHz | ||
| 2MHz~20MHz | 0.001MHz~0.01MHz |
5. Setup
- Power Connection:
- Ensure the multimeter's power switch (13) is in the OFF position.
- Locate the Voltage transfer switch (12) on the rear panel. Set it to match your local AC power supply (110V or 220V).
- Connect the provided power cable to the power outlet (15) on the rear of the multimeter and then to a suitable AC power source.
- Test Lead Connection:
- Insert the black test lead into the COM (Common) input terminal (8).
- For most measurements (voltage, resistance, frequency, capacitance), insert the red test lead into the V/Ω/Hz input terminal (9).
- For current measurements, insert the red test lead into the appropriate current input terminal (10 for 200mA, 11 for 2/20A). Always ensure the test leads are connected to the correct terminals for the measurement you intend to perform to prevent damage to the multimeter or circuit.
- Power On: Flip the power switch (13) to the ON position. The LCD display should light up.
6. Operating Instructions
This section outlines how to perform various measurements using your RuoShui 8045-II multimeter. Always ensure the multimeter is correctly set up and test leads are connected to the appropriate terminals before making any measurements.
General Measurement Procedure:
- Connect the test leads as described in the Setup section.
- Turn the Range knob (7) to the desired measurement function (e.g., Ω for resistance, V for voltage, A for current, F for capacitance, Hz for frequency, hFE for transistor testing).
- If the function has multiple ranges (e.g., 200mV, 2V, 20V for DC Voltage), the multimeter will typically auto-range. If not, select an appropriate range higher than the expected value.
- Connect the test probes to the circuit or component you wish to measure.
- Read the value on the LCD display (1).
- After measurement, disconnect the test probes from the circuit, then turn the Range knob to the OFF position and power off the multimeter.
Specific Measurement Examples:
Resistance Measurement:
- Turn the Range knob to the 'Ω' (Ohms) section.
- Connect the test probes across the component to measure its resistance.
- The display will show the resistance value in Ohms (Ω), kilo-Ohms (kΩ), or Mega-Ohms (MΩ).
Diode Measurement:
- Turn the Range knob to the diode symbol (▶|).
- Connect the red probe to the anode and the black probe to the cathode of the diode.
- The display will show the forward voltage drop. Reverse the probes; an open circuit (OL) reading indicates a good diode.
Capacitance Measurement:
- Turn the Range knob to the 'F' (Farad) section.
- Connect the test probes across the capacitor.
- The display will show the capacitance value in nano-Farads (nF), micro-Farads (µF), or milli-Farads (mF).
Voltage (AC/DC) Measurement:
- Turn the Range knob to the 'V' (Voltage) section.
- Use the AC+DC button (5) to select between AC (~) or DC (---) voltage.
- Connect the test probes in parallel with the circuit or component to measure voltage.
Current (AC/DC) Measurement:
- Turn the Range knob to the 'A' (Ampere) section.
- Ensure the red test lead is connected to the appropriate current input terminal (10 or 11).
- Use the AC+DC button (5) to select between AC (~) or DC (---) current.
- Connect the multimeter in series with the circuit to measure current.
Frequency Measurement:
- Turn the Range knob to the 'Hz' (Hertz) section.
- Connect the test probes to the circuit where you want to measure frequency.
Transistor (hFE) Measurement:
- Turn the Range knob to the 'hFE' section.
- Insert the transistor leads into the corresponding hFE sockets on the multimeter.
7. Maintenance
General Care:
- Keep the multimeter clean and dry. Wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents.
- Store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures.
- Avoid dropping the multimeter or subjecting it to strong impacts.
Fuse Replacement:
If the multimeter fails to measure current or shows incorrect readings in current modes, the fuse may need replacement. The fuse box (14) is located on the rear panel.
- Ensure the multimeter is powered OFF and disconnected from the AC power source.
- Carefully open the fuse box cover.
- Remove the old fuse.
- Replace it with a new fuse of the specified type and rating: 200mA/250V. Using an incorrect fuse can damage the multimeter or pose a safety hazard.
- Close the fuse box cover securely.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Multimeter does not power on | No AC power, power cable loose, power switch off, incorrect voltage selection. | Check AC power source. Ensure power cable is securely connected. Verify power switch is ON. Check Voltage transfer switch (110V/220V) setting. |
| No reading or "OL" (Overload) displayed | Incorrect range selected, open circuit, test leads not connected properly, component out of range. | Select a higher range or auto-range. Check for breaks in the circuit. Ensure test leads are firmly connected. Verify component is within measurement limits. |
| Incorrect current reading | Blown fuse, incorrect current input terminal used, multimeter not in series. | Check and replace fuse if necessary. Ensure red test lead is in the correct 'A' or 'mA' terminal. Connect multimeter in series with the circuit. |
| Display is dim or flickering | Low power supply voltage. | Ensure stable AC power supply. |
9. User Tips
- Always start with the highest range when measuring an unknown value to prevent overloading the multimeter.
- Ensure proper polarity when measuring DC voltage or current.
- When measuring resistance, ensure the circuit is de-energized to avoid inaccurate readings or damage.
- For precise capacitance measurements, ensure the capacitor is fully discharged before connecting the multimeter.
- Utilize the 'HOLD' function to freeze a reading on the display, which is useful when measuring in hard-to-reach areas.
- The 'MAX/MIN' function is excellent for capturing transient peaks or monitoring fluctuations over time.
10. Warranty and Support
RuoShui products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official RuoShui website. Please retain your proof of purchase for warranty claims.