1. Introduction

This manual provides comprehensive instructions for the XINJE XC2 Series Programmable Logic Controller (PLC). The XC2 series is designed for industrial automation applications, offering reliable control and high-speed processing capabilities. This document covers the features, technical specifications, and general guidelines for the setup, operation, and maintenance of your XC2 PLC.

Please read this manual thoroughly before attempting to install or operate the device to ensure safe and efficient use.

XINJE XC2 Series PLC in its packaging box with model details
Figure 1: XINJE XC2 Series PLC in original packaging, showing model XC2-32R-E.

2. Key Features

The XINJE XC2 Series PLC offers a range of features designed for robust industrial control:

  • Model Range: Available in 14, 16, 24, 32, 42, 48, and 60 point specifications.
  • Data Processing: Equipped with general data processing functions suitable for most industrial applications.
  • High-Speed Performance: Features high-speed computing processing, approximately twice the speed of the XC3 series.
  • Input Types: Supports both NPN and PNP input configurations.
  • Output Types: Available with transistor (T), relay (R), or transistor-relay mixed (RT) output options.
  • Power Supply: Operates on AC220V or DC24V power specifications.
  • High-Speed Counting: Supports high-speed counting up to 80KHz.
  • Pulse Outputs: Includes 2 high-speed pulse outputs, capable of up to 100KHz.
  • Communication:
    • Standard RS232 port for programming download.
    • Standard RS485 port for communication (available on models except 16 points).
  • Expansion: Supports external expansion BD boards (except for 14, 16, and 42 point models). Note that expansion modules are not supported.

3. Technical Specifications

Detailed specifications for the XINJE XC2 Series PLC models are provided below:

3.1 General Specifications

  • Brand: XINJE
  • Series: XC2 Series
  • Application: Lathe and Turning Center (Industrial Control)
  • High-concerned chemical: None
  • Origin: Mainland China

3.2 Model Listing and I/O Points

Table showing model numbers, power types, output types, input points, and output points for XINJE XC2 Series PLCs
Figure 2: XINJE XC2 Series PLC Model Listing and I/O Points.

For detailed input and output configurations, refer to the table above. The table categorizes models by AC or DC power, and by output type (Relay, Transistor, or Mixed R&T), along with their respective input and output point counts.

Table 1: XINJE XC2 Series PLC Model Specifications
Model numberInput points (DC24V)Output (R, T)
AC powerDC Power
Relay outputTransistor outputR&T mixed outputRelay outputTransistor outputR&T mixed output
NPNXC2-14R-EXC2-14T-EXC2-14RT-EXC2-14R-CXC2-14T-C-86
XC2-16R-EXC2-16T-E-XC2-16R-CXC2-16T-C-88
XC2-24R-EXC2-24T-EXC2-24RT-EXC2-24R-CXC2-24T-C-1410
XC2-32R-EXC2-32T-EXC2-32RT-E-XC2-32T-C-1814
XC2-42R-EXC2-42T-EXC2-42RT-E---2418
XC2-48R-EXC2-48T-EXC2-48RT-E-XC2-48T-C-2820
XC2-60R-EXC2-60T-EXC2-60RT-E---3624
PNP---XC2-14PR-CXC2-14PT-CXC2-14PRT-C86
XC2-16PR-E-XC2-16PRT-EXC2-16PR-CXC2-16PT-CXC2-16PRT-C88
XC2-24PR-EXC2-24PT-EXC2-24PRT-EXC2-24PR-CXC2-24PT-CXC2-24PRT-C1410
--XC2-32PRT-E---1814
XC2-42PR-E--XC2-42PR-C--2418
-XC2-48PT-EXC2-48PRT-EXC2-48PR-C-XC2-48PRT-C2820
-XC2-60PT-EXC2-60PRT-E-XC2-60PT-CXC2-60PRT-C3624

4. Setup and Installation

IMPORTANT: All XINJE XC2 Series PLCs require programming by qualified professionals before use. The device is shipped blank and cannot be operated without proper programming. Incorrect programming or installation can lead to system malfunction or damage.

4.1 Power Connection

  • Ensure the power source matches the PLC's specifications (AC220V or DC24V).
  • Connect the power supply to the designated power terminals on the PLC. Refer to the device labeling for exact terminal locations.
  • Verify all power connections are secure to prevent intermittent operation or damage.

4.2 Input/Output Wiring

  • Wire input devices (sensors, switches) to the PLC's input terminals according to the NPN or PNP configuration of your specific model.
  • Connect output devices (relays, actuators) to the PLC's output terminals, respecting the transistor (T), relay (R), or mixed (RT) output type.
  • Ensure all wiring adheres to industrial safety standards and local electrical codes.

4.3 Communication Ports

  • RS232 Port: Use this port to connect the PLC to a computer for programming download. A standard RS232 cable is required.
  • RS485 Port: For communication with other devices in a network (e.g., HMI, other PLCs), use the RS485 port. This port is available on most models, except for 16-point specifications.
  • Ensure proper termination and addressing for RS485 networks.

4.4 Expansion (BD Boards)

  • If your application requires additional functionality, external expansion BD boards can be connected.
  • Note that 14, 16, and 42 point models do not support external expansion BD boards.
  • The XC2 series does not support standard expansion modules.

5. Operation

Once the XINJE XC2 Series PLC is correctly installed and programmed by a professional, it will execute the programmed logic to control your industrial process.

  • Program Execution: The PLC continuously scans inputs, executes the user program, and updates outputs based on the logic.
  • High-Speed Functions: Utilize the high-speed counting (up to 80KHz) and high-speed pulse outputs (up to 100KHz) for precise control in applications requiring rapid response.
  • Monitoring: Use the programming software to monitor the PLC's status, input/output states, and internal registers during operation.

Caution: Any modifications to the PLC program or wiring should only be performed by trained personnel to avoid operational errors or equipment damage.

6. Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your XINJE XC2 Series PLC.

  • Environmental Control: Ensure the operating environment remains within specified temperature and humidity ranges. Protect the PLC from excessive dust, moisture, and corrosive gases.
  • Cleaning: Periodically clean the exterior of the PLC with a soft, dry cloth. Do not use harsh chemicals or solvents.
  • Connection Checks: Routinely inspect all wiring connections for tightness and signs of corrosion or damage. Re-tighten loose terminals as necessary.
  • Firmware Updates: Check the official XINJE website for any available firmware updates. Consult a professional for firmware update procedures.
  • Backup Programs: Regularly back up your PLC programs to an external storage device. This is crucial for quick recovery in case of data loss or PLC replacement.

7. Troubleshooting

This section provides general guidance for common issues. For complex problems, consult a qualified automation engineer or XINJE technical support.

Table 2: Common Troubleshooting Guide
ProblemPossible CauseSolution
PLC not powering onNo power supply; incorrect voltage; loose power connections.Verify power source and voltage. Check all power wiring and connections.
Inputs not respondingSensor malfunction; incorrect wiring (NPN/PNP); input terminal fault; program error.Check sensor operation. Verify input wiring matches PLC type. Inspect input terminals. Review PLC program logic.
Outputs not activatingOutput device malfunction; incorrect wiring; output terminal fault; program error.Check output device operation. Verify output wiring. Inspect output terminals. Review PLC program logic.
Communication failureIncorrect cable; wrong port settings (baud rate, parity); addressing conflict (RS485); software issue.Ensure correct communication cable. Verify port settings in software. Check RS485 addresses. Restart communication software.

8. User Tips

  • Professional Programming: Always ensure that the PLC is programmed by a professional. The device is delivered without pre-loaded programs and requires expert configuration for any application.
  • Customized Models (-C): Be aware that models ending with "-C" are customized products and may require a lead time of 1-2 weeks for preparation and ordering.
  • No Returns After Use: Due to the specialized nature and the requirement for professional programming, products, once used, are generally not eligible for return or replacement if the issue stems from programming or improper use by non-professionals.

9. Warranty and Support

For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your vendor. XINJE provides technical support for its products. In case of technical difficulties or inquiries, please contact XINJE customer service or your authorized distributor.

When contacting support, please have your PLC model number and any relevant error codes or symptoms ready to facilitate a quicker resolution.

© 2023 XINJE. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.