1. Introduction
This manual provides essential information for the installation, operation, and maintenance of your PowMr Hybrid Solar Inverter Charger. This device is a multi-functional inverter/charger, combining functions of an inverter, solar charger, and battery charger to offer uninterruptible power support in a portable size. Its comprehensive LCD display allows user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Key features include: Pure sine wave inverter, built-in MPPT solar charge controller, configurable input voltage range for home appliances and personal computers, configurable charging current based on applications, configurable AC/Solar input priority via LCD setting, compatible with mains voltage or generator power, auto restart while AC is recovering, overload/over temperature/short circuit protection, smart battery charger design for optimized battery performance, and cold start function.
2. Safety Instructions
Please read all instructions and cautionary markings on the unit and in this manual before operating the unit. This inverter contains dangerous voltages. Do not attempt to disassemble the unit. Refer all servicing to qualified service personnel. Improper installation or operation may result in electric shock, fire, or serious injury.
- Ensure all wiring is performed by a qualified electrician.
- Do not connect the unit to AC power if the wiring is not complete.
- Ensure the inverter is installed in a well-ventilated area, away from flammable materials.
- Do not expose the inverter to rain, snow, or liquids of any type.
- Use appropriate circuit breakers and fuses for all connections.
- Always disconnect all power sources (AC, PV, Battery) before performing any maintenance or wiring.
- Batteries can produce explosive gases; ensure proper ventilation and avoid sparks or flames near batteries.
3. Product Overview
The PowMr Hybrid Solar Inverter Charger is designed to provide reliable power for various applications. It integrates a high-efficiency pure sine wave inverter, an MPPT solar charge controller, and a battery charger.
3.1 Key Features
- Pure Sine Wave Output
- Built-in MPPT Solar Charge Controller (Max PV Input 4KW, 100A)
- Supports 12V and 24V battery systems
- Output Power: 2.3KW (12V AC) / 4.2KW (24V AC)
- Configurable AC/Solar input priority
- Compatible with Lead-Acid and Lithium batteries
- Overload, over temperature, and short circuit protection
- Smart battery charger design
- Cold start function
3.2 Components
The inverter features a clear LCD display for monitoring and configuration, along with intuitive buttons for navigation. The main unit includes terminals for AC input, AC output, PV input, and battery connections.


4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of the inverter. Follow these guidelines carefully.
4.1 Mounting the Inverter
- Choose a vertical wall mount location.
- Ensure adequate clearance for air circulation around the unit.
- Avoid direct sunlight, heat sources, and moisture.
- The operating temperature range is -20°C to 55°C.
4.2 Wiring Connections
Refer to the wiring diagram below for correct connections. All connections must be secure and properly insulated.

- Battery Connection: Connect the battery bank (12V or 24V DC) to the designated battery terminals. Ensure correct polarity. The inverter supports Lead-Acid and Lithium batteries.
- PV Input Connection: Connect your solar panels to the PV input terminals. The maximum open circuit voltage of the PV array is 500Vdc, with a maximum power of 4000W and MPPT current of 100A. The MPPT voltage range is 55V to 500Vdc.
- AC Input Connection: Connect the utility grid or a generator to the AC input terminals. Nominal input voltage is 220/230/240V, 50/60Hz.
- AC Output Connection: Connect your AC loads to the AC output terminals. The output power is 2.3kW for 12V AC systems and 4.2kW for 24V AC systems.
CAUTION: Ensure all DC and AC breakers are open before making any connections. Double-check all polarities and connections before applying power.
5. Operating Instructions
The inverter offers various operating modes to optimize power usage based on your needs.
5.1 Display and Control Buttons
The LCD display provides real-time system status and allows configuration of various parameters using the control buttons (typically Up, Down, Enter, and Escape/Power buttons).
5.2 Charging Modes
The inverter supports three distinct charging modes, configurable via the LCD display:

- Solar First: Prioritizes solar power for charging batteries. Utility power is used only if solar power is insufficient.
- Solar and Utility: Both solar and utility power are used to charge the batteries.
- Only Solar: Only solar power is used to charge the batteries. Utility power is not used for charging.
5.3 Output Load Operation Modes
The inverter also offers three output load operation modes to manage power delivery to your loads:
- Solar and Battery Load Priority (SBU Mode): Loads are primarily powered by solar energy. If solar is insufficient, power is drawn from batteries. Utility power is used as a last resort.
- Solar and Grid Load Priority (SUB Mode): Loads are primarily powered by solar energy. If solar is insufficient, utility power is used. Batteries are used as a last resort.
- Solar > Battery > Grid (MKS Mode): Loads are powered by solar first, then by batteries, and finally by the utility grid if both solar and battery power are unavailable.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Connection Check: Annually inspect all wiring connections (battery, PV, AC input/output) for tightness and corrosion. Tighten any loose connections.
- Battery Inspection: Check battery terminals for corrosion and clean if necessary. Ensure battery fluid levels (for flooded batteries) are adequate.
- Environment: Ensure the installation environment remains within the specified temperature and humidity ranges.
WARNING: Always disconnect all power sources before performing any maintenance.
7. Troubleshooting
This section provides basic troubleshooting steps for common issues. For more complex problems, contact customer support.
- No Power Output:
- Check all circuit breakers and fuses.
- Verify battery connections and voltage.
- Ensure AC input is present if configured for utility priority.
- Check for any error codes on the LCD display.
- Low Output Power:
- Ensure PV input is sufficient and solar panels are clean.
- Check battery health and charge level.
- Verify that the load does not exceed the inverter's rated capacity.
- Overload Warning:
- Reduce the connected load.
- The inverter has overload protection (5s@≥150% load; 10s@105%~150% load).
- Over Temperature Warning:
- Ensure adequate ventilation around the inverter.
- Clean any dust from the cooling fins.
- Reduce ambient temperature if possible.
8. Specifications
Detailed technical specifications for the PowMr Hybrid Solar Inverter Charger (Model: POW-HVM4.2K-24V-D).
8.1 LINE Mode Specifications

| INVERTER MODEL | POW-HVM4.2K-24V-D |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS) 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Battery mode: Electronic Circuits |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
Output power derating: When AC input voltage drops to 95V or 170V depending on models, the output power will be derated.
8.2 Inverter Mode Specifications

| INVERTER MODEL | DC12V-2300VA/2300W | DC24V-4200VA/4200W |
|---|---|---|
| Rated Output Power | 2300VA/2300W | 4200VA/4200W |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac ±5% | |
| Output Frequency | 60Hz or 50Hz | |
| Peak Efficiency | 94% | |
| Overload Protection | 5s@≥150% load; 10s@105%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 12 Vdc | 24 Vdc |
| Cold Start Voltage | 11.5 Vdc | 23.0 Vdc |
| Low DC Warning Voltage @ Load < 20% | 11.0 Vdc | 22.0 Vdc |
| Low DC Warning Voltage @ 20% ≤ Load < 50% | 10.7 Vdc | 21.4 Vdc |
| Low DC Warning Voltage @ Load ≥ 50% | 10.1 Vdc | 20.2 Vdc |
| Low DC Cut-off Voltage @ Load < 20% | 10.5 Vdc | 21.0 Vdc |
| Low DC Cut-off Voltage @ 20% ≤ Load < 50% | 10.2 Vdc | 20.4 Vdc |
| Low DC Cut-off Voltage @ Load ≥ 50% | 9.6 Vdc | 19.2 Vdc |
| High DC Cut-off Voltage | 16 Vdc | 32 Vdc |
| No Load Power Consumption | 20W | 30W |
| Saving Mode Power Consumption | <10W | <15W |
8.3 Charging Mode Specifications

| Utility Charging Mode | 12V | 24V |
|---|---|---|
| Battery Model | ||
| Charging Current (UPS) @Nominal Input Voltage | 100A | |
| Bulk Charging (Flooded Battery) | 14.6 | 29.2 |
| Bulk Charging (AGM / Gel Battery) | 14.1 | 28.2 |
| Floating Charging Voltage | 13.5Vdc | 27Vdc |
| Charging Algorithm | 3-Step | |
Solar Charging Mode:
| Max. PV Array Power | 4000W |
|---|---|
| I Max. PV | 18A |
| Nominal PV Voltage | 240V |
| PV Array MPPT Voltage Range | 55V-500V |
| Max. PV Array Open Circuit Voltage | 500V |
| Max Charging Current | 100A |
8.4 General Specifications

| Operating Temperature Range | -20°C to 55°C |
|---|---|
| Storage temperature | -20°C ~ 60°C |
| Dimension (D*W*H), mm | 405*305*108 |
| Net Weight, kg | 6.7 |
9. User Tips
Based on common user experiences and best practices:
- Battery Compatibility: Ensure your battery type (Lead-Acid, Lithium) is correctly configured in the inverter settings for optimal charging and discharge performance.
- Ventilation: Always ensure the inverter has ample space for airflow. Overheating can reduce efficiency and lifespan.
- Grounding: Proper grounding is essential for safety and to prevent electrical interference.
- Monitoring: Regularly check the LCD display for system status and any warning indicators to catch potential issues early.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized dealer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
Certifications: CE, FCC, RoHS.