1. Product Overview
The TSUN TS-50 is a magnetic grid displacement digital display table designed for precise measurement and control in various industrial applications, particularly with cutting machines. It features an absolute type measuring system, integrating a magnetic displacement sensor with a power relay output. The unit offers high precision, real-time data tracking, and multiple compensation functions for reliable performance.


2. Key Features
- Absolute type measuring system with integrated magnetic displacement sensor and power relay output.
- Six-digit highlight digital tube display for clear readings.
- Metric and inch measurement unit swapping.
- Manual and single-acting operation modes.
- Ability to store 10 single action data points.
- Adaptive motion inertia for stable operation.
- Compensates for fixed screw clearance errors.
- High-reliability relay output for directional, high-speed, and precise positioning.
- Utilizes a magnetic displacement sensor for accurate readings.
- Equipped with a backup battery for continuous displacement tracking and real-time data even if external power is disconnected.
- Multiple compensation functions for enhanced accuracy.
3. Setup and Installation
3.1 Unpacking and Inspection
Carefully unpack the TS-50 unit and its components. Verify that all parts are present and undamaged. The package should include the digital display unit, magnetic displacement sensor, and magnetic grid ruler.


3.2 Mounting
The TS-50 unit is designed for fixed-type mounting. Ensure a stable and secure location for installation, away from excessive vibration, heat, or moisture. Refer to the dimension diagrams for appropriate cutout sizes if panel mounting.


3.3 Wiring
Important Safety Note: Ensure the power supply is disconnected before performing any wiring. Wiring should only be performed by qualified personnel.
Connect the power supply (AC220V or AC110V) and the magnetic displacement sensor to the appropriate terminals on the back of the unit. The sensor cable length can be customized from 1m to 15m. Ensure all connections are secure.

Initial Setup Warning: Before first use, open the back cover and set the internal toggle switch to the 'ON' position. This is crucial for proper operation.
4. Operating Instructions
4.1 Front Panel Controls

The front panel features a six-digit digital display and a keypad for input and control:
- Numeric Keys (0-9): Used for entering numerical values.
- 'C' Key: Clear or cancel current input.
- '+/-' Key: Toggles the sign of the displayed value.
- 'STEP' Key: Likely used for step-by-step adjustments or mode selection.
- 'ENTER' Key: Confirms input or selection.
- 'SET' Key: Enters setup or configuration mode.
- 'ESC' Key: Exits current mode or cancels an operation.
- Green Button (Power ON): Turns the unit on.
- Red Button (Power OFF): Turns the unit off.
- Up/Down Arrows: Used for navigation or adjusting values in certain modes.
- 'mm' / 'inch' Indicators: Show the current measurement unit.
- 'input' / 'run' Indicators: Show the current operational status.
4.2 Basic Operation
- Power On: Press the green power button.
- Unit Selection: Use the 'SET' key to access settings and switch between metric (mm) and imperial (inch) units as needed.
- Measurement: The display will show the displacement measured by the magnetic sensor in real-time.
- Data Storage: The unit supports storing up to 10 single action data points. Refer to the detailed programming guide (if available) for instructions on how to save and recall these values.
- Operation Modes: The unit can operate in manual or single-acting modes. Select the desired mode via the 'SET' or 'STEP' keys.
5. Maintenance
5.1 Cleaning
Wipe the display unit and sensor with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the surfaces. Ensure no liquids enter the unit.
5.2 Backup Battery
The unit is equipped with 1.2V*3 (LR14) backup batteries, providing approximately 2.5 years of life. These batteries ensure data retention and real-time tracking even when external power is disconnected. It is recommended to check the battery status periodically and replace them when necessary to maintain this functionality. Refer to the back panel image (Figure 7) for the battery compartment location.
5.3 Environmental Conditions
The sensor has an IP67 protection rating, indicating it is dust-tight and protected against temporary immersion in water. However, prolonged immersion should be avoided. The unit is designed to operate within a working temperature range of -10℃ to +60℃ and a storage temperature range of -30℃ to +80℃. Avoid exposing the unit to extreme temperatures or humidity.
6. Troubleshooting
- No Display/Unit Not Powering On:
- Check the main power connection (AC220V/AC110V).
- Ensure the internal toggle switch on the back panel is set to 'ON' (refer to Figure 7).
- Verify the backup batteries are correctly installed and have sufficient charge.
- Inaccurate Readings:
- Ensure the magnetic displacement sensor is correctly aligned with the magnetic grid ruler.
- Check for any physical damage or debris on the sensor or ruler.
- Verify the sensor cable is securely connected.
- Consider if environmental factors (e.g., strong magnetic fields) are interfering.
- Relay Output Malfunction:
- Check the relay output wiring for correct connections.
- Ensure the output load does not exceed the specified contact power output (AC220V/5A, DC24V/10A).
If issues persist, contact technical support.
7. Specifications
| Feature | Specification | Notes |
|---|---|---|
| Repeat accuracy | 0.01mm | Unit: mm |
| Range of measurement and control | -19999.9mm ~ 9999.9mm | |
| Display resolution | 0.01mm/0.05mm/0.1mm | Can be set to |
| Power supply voltage | AC220V/AC110V | |
| Backup battery | 1.2V*3 (LR14) | Life is about 2.5 years |
| Machine power consumption | <4W | |
| Control speed | MAX2.5m/s | |
| Matching magnetic ruler | 0.5mm ~ 2.0mm | |
| Output form | Relay normally open | |
| Contact power output | AC220V/5A DC24V/10A | |
| Sensor cable length | 1m ~ 15m | Can be customized |
| Sensor protection rating | IP67 | |
| Working temperature | -10℃ ~ +60℃ | |
| Storage temperature range | -30℃ ~ +80℃ | |
| Shell | Metal |
8. User Tips
- Sensor Alignment: For optimal accuracy, ensure the magnetic displacement sensor is perfectly aligned and parallel to the magnetic grid ruler throughout its travel path. Any misalignment can lead to measurement errors.
- Data Storage for Repetitive Tasks: Utilize the 10 single action data storage slots for frequently used measurements or positions. This can significantly speed up repetitive operations.
- Unit Conversion: Take advantage of the metric/inch swapping feature to seamlessly integrate the TS-50 into different measurement systems without manual conversions.
- Power Management: While the backup battery provides continuity, it's good practice to ensure stable external power during critical operations to avoid reliance on battery power for extended periods.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer or your authorized dealer. Keep your purchase receipt as proof of purchase.
Manufacturer Contact Information:
JINAN OUNA ELECTRICAL AND MECHANICAL EQUIPMENT CO., LTD.Tel: +86 18660126069
Whatsapp: +8618660126069
Email: redking2008@126.com
Address: D12-103, Lanxiang Road Times Headquarters Base, Tianqiao District, Jinan City, Shandong Province