Universal for Various Applications

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the SUSWE General Vector Inverter. This heavy-duty, three-phase inverter is designed for precise motor speed regulation in a wide range of applications. It supports both three-phase 380V and single-phase 220V input/output configurations, offering versatility and robust performance.

Key features include:

  • Motor speed regulation
  • Advanced vector control technology
  • Human-machine interactive ergonomic design control panel
  • High-quality, flame-retardant plastic casing
  • Cutting-edge motherboard for stable performance

2. Safety Information

WARNING: Read the user's manual thoroughly before installation or operation. Do not open the cover while applying power and wait at least 10 minutes after disconnecting power before handling internal components to avoid electric shock.

Always ensure proper grounding and adhere to all local electrical codes and safety regulations during installation and operation. Only qualified personnel should perform wiring and maintenance.

3. Product Overview and Components

The SUSWE General Vector Inverter features a classic control panel layout designed for user-friendly interaction. The main unit is constructed with flame-retardant plastic for durability and safety, housing a cutting-edge motherboard for reliable performance.

Control Panel

Control panel layout with various buttons and a display

Image: Detailed view of the inverter's control panel, highlighting the display, speed adjustment knob, and various function keys.

Key Instructions

Key SymbolNameFunction Description
PRGProgramming keysMenu entry or exit, parameter modification
ENTERDetermine keyEnter the menu and confirm parameter settings
▲ ▼Delivery keysTransfer of data or function code selection, parameter modification
RUNRunning keyOperation under keyboard operation
STOP/RESETStop/reset keyStop/reset operation
MF.KMultifunctional shortcut keysSwitch according to function selection

Indicator Light Description

Table describing indicator lights on the inverter

Image: Table detailing the meaning of various indicator lights on the inverter's display, such as RUN, FWD/REV, TUNE/TC, Hz, A, and V.

4. Specifications

AttributeValue
Brand NameSUSWE
Model NumberSUSWE (various power ratings)
TypeDC/AC Inverters
Output TypeTriple
Output Frequency50/60Hz
Output Current25A (Rated)
Supply Voltage220V / 380V
Adapted Motor Power0.75/1.5/2.2/4/5.5/7.5kW
Control MethodVF (Vector Control)
Output Voltage Regulation MethodVector Control
FilterWith filter
Power Phase Count3
Weight1.2 kg
Size30 (dimensions vary by model, refer to dimension table)
CertificationCE
OriginMainland China

Dimensions

Diagram showing the dimensions of the inverter unit

Image: Diagram illustrating the physical dimensions (H, W, D, A, B, C) of the inverter unit.

5. Installation and Wiring

Proper installation and wiring are crucial for the safe and efficient operation of the inverter. Ensure the unit is mounted in a suitable environment, away from direct sunlight, excessive dust, moisture, and corrosive gases. Allow adequate ventilation for heat dissipation.

Wiring Diagrams

Input Three-Phase 380V, Output Three-Phase 380V

Wiring diagram for 3-phase 380V input and output

Image: Wiring diagram showing a three-phase 380V input from a circuit breaker (R, S, T) connected to the inverter, and the inverter's output (U, V, W) connected to a three-phase motor. A ground wire is also shown connected to the inverter and motor.

Input Single-Phase 220V, Output Three-Phase 220V

Wiring diagram for single-phase 220V input and 3-phase 220V output

Image: Wiring diagram illustrating a single-phase 220V input from a circuit breaker (L, N) connected to the inverter, and the inverter's output (U, V, W) connected to a three-phase motor. A ground wire is also shown connected to the inverter and motor.

Control Terminal Wiring

Detailed wiring diagram for control terminals

Image: Detailed wiring diagram for the inverter's control terminals, including digital inputs (GND, X1-X5), analog inputs/outputs (AVI, ACI, AO), relay outputs (TC, TB, TA), and motor output (U, V, W, PE).

Important Wiring Notes:

  • Ensure all connections are secure and properly insulated.
  • Verify input voltage matches the inverter's rating before connecting power.
  • Connect the ground wire to a reliable earth ground.
  • Do not connect the input power to the output terminals (U, V, W).

6. Operation

The inverter is designed for straightforward operation using its intuitive control panel.

Basic Motor Speed Control

  1. Power On: Ensure all wiring is correct and secure. Turn on the main power switch to supply power to the inverter.
  2. Start Operation: Press the RUN button on the control panel. The inverter will begin operation, and the motor will start rotating.
  3. Adjust Speed: Rotate the speed adjustment knob (potentiometer) on the control panel to increase or decrease the motor's rotational speed. The display will show the current frequency/speed.
  4. Stop Operation: To stop the motor, press the STOP/RESET button. The motor will slowly decelerate and come to a stop.
  5. Power Off: Once the motor has completely stopped, turn off the main power switch.

Operation Demonstration Video

Video: A demonstration of connecting the inverter to a motor and controlling its speed using the control panel's RUN, STOP, and speed adjustment knob functions.

Advanced Settings

For advanced parameter configuration, refer to the detailed programming guide in the full product manual (if available). Use the PRG and ENTER keys to navigate menus and adjust settings such as acceleration/deceleration times, frequency limits, and control modes.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your SUSWE General Vector Inverter.

  • Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust accumulation, which can hinder heat dissipation. Use a soft, dry cloth. Do not use liquid cleaners.
  • Inspection: Regularly inspect all wiring connections for tightness and signs of wear or damage. Check for any unusual noises or odors during operation.
  • Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
  • Power Disconnection: Always disconnect power and wait at least 10 minutes before performing any inspection or maintenance to allow capacitors to discharge.

8. Troubleshooting

This section provides solutions to common issues you might encounter. For complex problems, contact technical support.

ProblemPossible CauseSolution
Motor does not startNo power, incorrect wiring, emergency stop active, parameter errorCheck power supply, verify wiring, release emergency stop, reset parameters to default or correct settings.
Inverter displays an error codeOvercurrent, overvoltage, undervoltage, overload, overheatingRefer to the full manual for specific error code meanings and corrective actions. Check motor load, input voltage, and ventilation.
Motor speed unstableIncorrect parameter settings, motor load fluctuationsAdjust PID parameters or V/F curve. Ensure motor load is stable.
Unusual noise from motor/inverterLoose connections, motor issues, inverter faultCheck all connections. Inspect motor for damage. If noise persists, contact technical support.

9. User Tips

  • For optimal performance, ensure the inverter's power rating closely matches your motor's power requirements.
  • When adjusting speed, make gradual changes using the knob to avoid sudden motor stress.
  • Always keep a copy of the full technical manual (if provided) for detailed parameter settings and advanced troubleshooting.

10. Warranty and Support

For any technical assistance, warranty claims, or further inquiries, please contact the seller or manufacturer directly. Ensure you have your product model number and purchase details ready when seeking support.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.