1. Introduction
This manual provides essential information for the safe and efficient operation of your DAXTROMN AGH-4.2KW-PRO Hybrid Solar Inverter. This advanced inverter is designed for 24VDC battery systems, offering a rated power of 4.2KW, and supports MPPT solar charging with a maximum PV input of 500V. It is capable of both grid-tie operation and can function without a battery, providing a versatile solution for your solar energy needs. Please read this manual thoroughly before installation and use.
2. Product Overview
The DAXTROMN AGH-4.2KW-PRO Hybrid Solar Inverter integrates multiple functions to provide a comprehensive power solution. Below is an overview of its main components and their functions.

Key Components:
- LCD display: Shows system status and operational data.
- Status indicator: Indicates the current operational status of the inverter.
- Charging indicator: Shows the battery charging status.
- Fault indicator: Illuminates to signal system faults or errors.
- Function buttons: Used for navigating menus and adjusting settings on the LCD.
- Power on / off switch: Controls the main power to the inverter.
- AC input: Connection point for grid or generator AC power.
- Main output: Primary AC output for connected loads.
- Second output: Auxiliary AC output for additional loads.
- Battery input: Connection terminals for the 24VDC battery bank.
- PV input: Connection terminals for solar panel arrays.
- WiFi communication/RS-232 port: For monitoring and communication with external devices.
- Battery communication/RS-485 port: For advanced battery management system (BMS) communication.


3. Specifications
The following table details the technical specifications of the DAXTROMN AGH-4.2KW-PRO Hybrid Solar Inverter.

| Feature | Specification |
|---|---|
| Model Number | AGH-4.2KW-PRO |
| Color | White and Black |
| Operating Temperature Range | -10~50°C |
| PV Input | |
| Nominal operating voltage | 240Vdc |
| Vmax PV | 500Vdc |
| PV input voltage range | 60-450Vdc |
| Imax PV | 18A |
| Full load MPPT range | 240-450Vdc |
| Maximum PV input power | 6200W |
| Maximum Solar Charging Current | 120A |
| Grid/AC Output | |
| Nominal Output Voltage | 220/230/240Vac |
| Feed-in Grid Voltage Range | 195-253Vac |
| Feed-in Grid Frequency Range | 49-51±1Hz |
| Nominal Output Current | 18.2A |
| Power Factor Range | >0.99 |
| Maximum Conversion Efficiency (DC/AC) | 97% |
| Nominal Operating Frequency | 50/60Hz |
| Two Load Output Power | |
| Full Load | 4200W |
| Maximum Main Load | 4200W |
| Maximum Second Load | 1400W |
| Min. Load Cut Off Voltage | 26Vdc |
| Main Load Return Voltage | 27Vdc |
| AC Input | |
| Nominal operating voltage | 230Vac |
| Maximum input current | 30A |
| Nominal operating frequency | 50/60Hz |
| Surge power | 8400VA |
| Maximum AC Charging Current | 100A |
| Battery | |
| Battery voltage | 24Vdc |
| Maximum battery current | 175A |
| Certifications | RoHS Compliant, CE |
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. It is recommended that installation be performed by a qualified electrician.
4.1. Unpacking and Inspection
Upon receiving your inverter, carefully unpack it and inspect for any signs of damage. Ensure all components, including the Wi-Fi module and cables, are present as per the packing list.

4.2. Mounting
Mount the inverter in a well-ventilated area, away from direct sunlight, moisture, and flammable materials. Ensure there is adequate clearance around the unit for proper airflow and cooling.
4.3. Wiring Connections
Refer to the connection diagram below for proper wiring of the solar panels, battery bank, AC input (grid/generator), and AC output (home appliances). All wiring must comply with local electrical codes and standards.

- Solar Power (PV Input): Connect your solar panel array to the PV input terminals. Ensure the PV input voltage and current are within the specified ranges (60-450Vdc, max 18A). The maximum PV input power is 6200W.
- External Battery Packs (Battery Input): Connect a 24VDC battery bank to the battery input terminals. The inverter supports adjustable charging voltage for external battery packs.
- Generator or Utility (AC Input): Connect your AC power source (grid or generator) to the AC input terminals.
- Home Appliances (AC Output): Connect your loads to the Main Output and Second Output terminals. The inverter provides 220/230/240Vac output.
Important Safety Note: Always ensure all power sources are disconnected before making any wiring connections. Incorrect wiring can cause damage to the inverter, personal injury, or fire.
5. Operating Instructions
The DAXTROMN AGH-4.2KW-PRO inverter features an intuitive LCD display and function buttons for easy operation and monitoring.
5.1. Powering On/Off
Use the Power on/off switch (component 6 in Figure 2.1) to turn the inverter on or off. Observe the status, charging, and fault indicators (components 2, 3, 4) for system status.
5.2. LCD Display and Settings
The LCD display (component 1) provides real-time information about the system's performance, including PV input, battery status, AC input/output, and load consumption. Use the function buttons (component 5) to navigate through the display menus and adjust operational parameters as needed. Consult the full user manual (if available) for detailed menu navigation and parameter settings.
5.3. Operating Modes
This hybrid inverter supports various operating modes, including grid-tie operation and batteryless working. Specific mode selection and configuration can be done via the LCD display and function buttons. Ensure the chosen mode aligns with your energy requirements and local grid regulations.
6. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Cleaning: Keep the inverter's exterior clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Ventilation: Ensure that the ventilation openings are not blocked to prevent overheating.
- Connections: Periodically check all electrical connections for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
- Environmental Conditions: Ensure the inverter operates within its specified temperature range (-10~50°C) and humidity levels.
For any internal maintenance or repairs, contact qualified service personnel.
7. Troubleshooting
If you encounter issues with your inverter, refer to the fault indicator (component 4 in Figure 2.1) and the LCD display for error codes or messages. Below are some general troubleshooting steps:
- No Power: Check the main power switch, AC input connections, and battery connections. Ensure the battery voltage is sufficient.
- No Output: Verify that the loads are properly connected and not exceeding the inverter's output capacity. Check for any fault indicators.
- Fault Indicator On: Refer to the inverter's display for specific error codes. Common issues include over-voltage, under-voltage, overload, or short circuit.
- Poor Performance: Check solar panel connections and ensure they are clean and unobstructed. Verify battery health and charge level.
If the problem persists after performing these checks, contact customer support.
8. User Tips
- Check Included Accessories: Upon delivery, ensure all components, especially the Wi-Fi module, are included and undamaged.
- Adjustable Battery Charging: Take advantage of the adjustable charging voltage feature for external battery packs to optimize battery life and performance.
- Monitor System Performance: Utilize the Wi-Fi communication or RS-232/RS-485 ports for remote monitoring of your inverter's performance and energy production.
- Professional Installation: For safety and optimal performance, consider professional installation, especially for complex wiring or grid-tie configurations.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly. Keep your purchase receipt and product serial number handy when contacting support.
The product serial number can be found on the specification label (refer to Figure 3.1).