1. Introduction
The Jebao Jecod DCS series DC pumps are carefully inspected and tested to ensure both safety and optimal operating performance. This manual provides essential instructions and warnings to ensure proper use and to prevent damage or injury. Please read and save this manual for future reference.
2. Safety Information
2.1. Warnings
- Do not connect to any other power supply over the rated voltage.
- Do not place the pump in flammable liquid.
- Do not use the pump in water temperatures above 35°C.
- The maximum diving depth for the pump is 1.5 meters.
- Do not immerse the power plug into water or any other liquid.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- For indoor use, the power socket must be installed with a leakage current protecting device, and the leakage current shall not exceed 30mA.
2.2. Cautions
- Always disconnect the pump from the power supply before cleaning, maintenance, and handling.
- Do not let the pump run dry.
- Do not lift the pump by holding the power cord only.
- Do not use the pump in heating liquid.
- The pump is suitable for both fresh and marine water.
- Use the pump only when it is completely submerged in water.
- The pump cannot run in a swimming pool.
- The pump will automatically shut off if no water is detected for 2 minutes.
- If the pump shuts off, pull the plug out and re-insert for resuming work.
3. Product Features
3.1. Pump Features
- High performance with an innovative motor, offering energy savings of up to 50%.
- Super quiet operation.
- Suitable for both marine and fresh water environments.
- Rust-free design.
- Equipped with an anti-resistant ceramic shaft for extended lifespan.
3.2. Controller Features
- 10 adjustable flow rate modes and head max settings.
- "Feed" mode with pause, timing, delay, and restart functions.
- Memory function ensures the pump restarts with the last used parameters after power interruption.


4. Specifications
The pump operates on DC 24V. The input voltage for the adapter is 110-240V.
4.1. Performance Parameters Table
| No. | Model No. | Voltage | Control box (W) | Consumption (W) | Flow rate (L/H) | Head Max (M) |
|---|---|---|---|---|---|---|
| 1 | DCS-4000 | DC24V | 50 | 30 | 4000 | 3.2 |
| 2 | DCS-5000 | DC24V | 50 | 40 | 5000 | 3.5 |
| 3 | DCS-7000 | DC24V | 100 | 55 | 7200 | 4.5 |
| 4 | DCS-9000 | DC24V | 100 | 65 | 9000 | 5.2 |
| 5 | DCS-12000 | DC24V | 100 | 80 | 12000 | 6.0 |

4.2. Product Dimensions


5. Setup and Installation
5.1. Unboxing and Components
The product package includes the pump body, power cable, controller, mesh cover, various water joints, rubber pads, and an instruction manual.




5.2. Connecting the Components
- Connect the pump to the controller. Ensure the arrows on the connectors align and tighten the screw cap.
- Connect the controller to the power adapter.
- Plug the power cable into the adapter.
- Ensure the electrical cord forms a "Drip Loop" below the power socket to prevent water from running along the cable into the socket.
5.3. Installing Water Pump Outlet Connectors
Select the appropriate water joint size based on your specific needs. The pump comes with various adapters to connect to different pipe sizes.
- For submersible use, the mesh cover can be installed on the pump inlet.
- For land-based use, remove the side mesh cover and attach the desired water joint.


6. Operation
6.1. Initial Start-up
Once all connections are secure and the pump is submerged (if applicable), turn on the power. The pump may not immediately pump water due to air in the system. Don't worry; plug and unplug the power several times until it starts working normally.
6.2. Adjusting Flow Rate and Head
Use the "+" and "-" buttons on the controller to adjust the pump flow rate and head max. The LED instruction light will indicate the current mode.

6.3. Lock/Unlock Function
To lock the controller, press the "+" or "-" button for three seconds until the LED light flashes twice. The controller is now locked. To unlock, repeat the process: press "+" or "-" for three seconds until the LED light flashes twice.
6.4. "FEED" Function
When the pump is running, press the "FEED" button to activate the feed mode. The pump will stop working, and the "10min" indicator will light up. The pump will automatically resume operation at its previous level after 10 minutes. You can also press the "FEED" button again to manually restart the pump.
7. Maintenance
7.1. Cleaning the Pump
Regular monthly maintenance will prolong your pump's life. Always disconnect the power supply before cleaning.
- Remove the back cover, sealing cover, and the impeller.
- Use a small brush or a stream of water to remove any debris.
- Clean the rotor and remove any dirt.
- Note: The pump shaft cannot be removed.


7.2. Operation in Dirty Conditions
A clogged or dirty intake screen will reduce performance. If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the intake. If the flow is low, adjust the regulator on the sealing cover.
8. Troubleshooting
If the pump is not working, check the following:
8.1. LED Flashing Status Instruction
| No. | Controller Working Status | LED Flashing Status | Elimination of Abnormal Phenomena |
|---|---|---|---|
| 1 | Over voltage or under voltage | Red LEDs flashing | Check the input supplying voltage |
| 2 | Controller overheating | Red LEDs flashing | Check whether the controller is exposed to direct sunlight or in a high-temperature environment |
| 3 | The impeller stops running | Red LEDs flashing | Check whether something is in the pump or if the parts are wrongly connected |
| 4 | Pump idling | Red LEDs flashing | Check the pump work dry |
| 5 | Abnormal current of the controller | Red LEDs flashing | Check if the pump is short of voltage or if the controller is broken |
| 6 | Lock or unlock | LED indicator flashing for two times | The key may be broken if the light doesn't flash after pressing "+" or "-" for 3 seconds. |

8.2. General Troubleshooting Steps
- Check the circuit: Try plugging the pump into another power socket to ensure it's receiving power.
- Check pump outlet and tube: Inspect for blockages caused by dirt or algae. Clean as necessary.
- Check the inlet: Ensure it is not clogged by debris.
- Access the impeller: Remove the pump inlet and turn the rotor to check if it's broken or jammed.
9. User Tips
- Users have reported that the pump operates very quietly, making it suitable for environments where noise reduction is important.
- The pump's DC 24V operation and 110-240V adapter provide flexibility for various power setups.
10. Disposal
Do not dispose of this product as unsorted municipal waste. Separate collection of such waste is necessary for special treatment. This product must not be disposed of with domestic waste. It should be disposed of at an authorized place for recycling electrical and electronic appliances. By collecting and recycling waste, you help conserve natural resources and ensure environmentally sound disposal.
11. Warranty and Support
For support or inquiries, please contact:
Jecod Co.,LtdTongmao Industrial Park, Dongsheng, Zhongshan, Guangdong, China.
Email: info@jecod.com
Website: www.jecod.com
Tel: +86-760-28136717/19/20
Fax: +86-760-28136725
A user manual in PDF format is available for download: Jebao Jecod DCS Series User Manual (PDF)