This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Haier EI60C1(W) 6kW Tankless Electric Instant Water Heater. Please read this manual thoroughly before installation and use, and keep it for future reference.

Haier 6kW Tankless Electric Instant Water Heater front view

Figure 1: Haier EI60C1(W) Water Heater

2. Safety Information

Your Haier water heater is designed with multiple safety features. Adherence to these guidelines is crucial for safe operation.

2.1 General Safety Precautions

  • Ensure proper grounding. The unit features Ground Detection Warning.
  • Do not operate the unit if the power cord or plug is damaged.
  • Keep the unit away from flammable materials.
  • Do not attempt to repair the unit yourself. Contact qualified service personnel.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

2.2 Built-in Safety Features

  • Shock Proof Technology: Patented technology to prevent electric shock.
  • ELCB (Earth Leakage Circuit Breaker): Provides protection against electrical leakage.
  • Anti Leakage: Designed to prevent water leakage.
  • Anti Corrosion: Materials chosen for durability and resistance to corrosion.
  • Low Flow Protection: Ensures the heater does not operate without sufficient water flow.
  • IP25 Waterproof Grade: Protects against water jets from any direction.
  • Ultra-temperature protection: Automatically shuts off if water temperature exceeds safe limits (95°C breakpoint).
  • Dry Burning Prevention: Prevents the heating element from operating without water.
  • Safe Voltage Technology: Physically converts rated voltage to a safe voltage, ensuring safety even in cases of no earthing, fault earthing, or electric leakage.
Diagram illustrating safe voltage technology

Figure 2: Safe Voltage Technology Principle

3. Specifications

FeatureSpecification
ModelEI60C1(W)
BrandHaier
Product TypeClosed-type
Tank MaterialsCast Aluminium
Heating Element3D Heating Technology (2 groups)
Controlling ModeIntelligent Control
InstallationUnder Sink / For pipelines
Housing MaterialABS (White/Injection Molding)
Product Dimensions (H/W/D)245*265*83 mm
Net Weight2.13 kg
Gross Weight2.78 kg
Temperature Setting Range30-55°C
Overtemperature Thermostat Breakpoint95°C
Waterproof GradeIP25
Rated Voltage/Frequency220V/50Hz
Rated Power6000 W
Rated Pressure0.6 Mpa
Minimum Water Pressure0.03 Mpa
Maximum Water Pressure0.6 Mpa
Activation Flow2 L/min
Temperature SensorYes
Temperature/Power ControlTemperature Control
Shower HeadOptional (Ag+ Anti-Bacterial)
Diagram showing product dimensions: Height 265mm, Width 245mm, Depth 83mm

Figure 3: Product Dimensions

4. Components Overview

4.1 Control Panel

The water heater features an intuitive control panel for easy operation.

Diagram of the control panel with labels for ELCB, Heating display, ELCB test, Earthing test, ELCB reset, Temperature, and Power buttons.

Figure 4: Control Panel Layout

Key elements:

  • Power Button: Turns the unit on/off.
  • Temperature Adjustment (+/-): Increases or decreases the desired water temperature.
  • ELCB Test Button: For testing the Earth Leakage Circuit Breaker.
  • ELCB Reset Button: Resets the ELCB after a trip.
  • Heating Display: Indicates when the unit is actively heating water.
  • Earthing Test: Indicator for earthing status.

4.2 Water Connections

The unit has clearly marked water inlet (blue) and outlet (red) connections at the bottom.

Bottom view of the water heater showing blue water inlet and red water outlet connections

Figure 5: Water Inlet and Outlet

The internal structure includes water-in and water-out temperature sensors for precise control.

Internal view showing water-out and water-in temperature sensors

Figure 6: Internal Temperature Sensors

5. Installation

Installation should be performed by a qualified professional in accordance with local plumbing and electrical codes.

5.1 Mounting Location

  • The unit is designed for under-sink installation or for pipelines.
  • Choose a location that is easily accessible for maintenance and away from direct water spray.
  • Ensure the mounting surface is strong enough to support the unit's weight (Net Weight: 2.13 kg).

5.2 Plumbing Connections

  • Connect the cold water supply to the blue inlet pipe and the hot water outlet to the red pipe.
  • Ensure all connections are watertight.
  • The unit requires a minimum water pressure of 0.03 Mpa and a maximum of 0.6 Mpa.
  • The activation flow is 2 L/min.

5.3 Electrical Connections

  • The unit requires a 220V/50Hz power supply with a rated power of 6000W.
  • A dedicated circuit and proper grounding are essential.
  • Always ensure the ground wire is correctly connected to utilize the patented Shock Proof Technology and ELCB features.

6. Operation

6.1 Initial Startup

  1. Ensure the unit is properly installed and connected to water and power.
  2. Open a hot water faucet to allow water to flow through the unit and purge any air from the system.
  3. Once water flows steadily, close the faucet.
  4. Press the Power button on the control panel to turn on the unit.

6.2 Setting Temperature

  • Use the '+' and '-' buttons on the control panel to adjust the desired water temperature.
  • The temperature setting range is 30-55°C.
  • The LED display will show the current temperature setting.

6.3 ELCB Test and Reset

  • Regularly test the ELCB by pressing the 'TEST' button. The ELCB should trip, cutting off power.
  • To restore power, press the 'RESET' button. If the ELCB does not trip or reset, contact a qualified technician.

6.4 Shower Head Functions (if applicable)

If your model includes the multi-functional shower head, you can select from different spray patterns:

  • RAIN Mode: Provides a gentle, rain-like spray for a relaxing experience.
    Shower head in Rain mode
  • COMBO Mode: A combination of rain and massage functions for a varied shower experience.
    Shower head in Combo mode
  • MASSAGE Mode: Delivers a high-pressure spray to massage specific body points.
    Shower head in Massage mode

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your water heater.

  • Cleaning: Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Scale Prevention: The 3D Heating Technology and Copper Tank are designed to be anti-scale, reducing the need for frequent descaling.
  • Anti-Bacterial Shower Head: If your unit includes the Ag+ Anti-Bacterial shower head, the silver ion material helps inhibit 99.9% of bacteria. Clean the shower head nozzles regularly to prevent mineral buildup.
  • ELCB Testing: Perform the ELCB test monthly as described in the operation section.

8. Troubleshooting

Before contacting service, check the following common issues:

  • No Hot Water:
    1. Check if the power supply is on and the unit is plugged in.
    2. Ensure the ELCB has not tripped. Reset if necessary.
    3. Verify water supply is open and water pressure is sufficient (above 0.03 Mpa).
    4. Check if the temperature setting is appropriate.
  • Water Not Hot Enough:
    1. Increase the temperature setting using the '+' button.
    2. Ensure sufficient water flow (above 2 L/min). Low flow can sometimes lead to less effective heating.
    3. Check for any blockages in the shower head or water lines.
  • Water Leakage:
    1. Immediately turn off the power and water supply to the unit.
    2. Check all water connections for tightness.
    3. If leakage persists, contact a qualified technician.
  • ELCB Trips Frequently:
    1. This indicates an electrical fault. Immediately turn off the unit and contact a qualified electrician or service personnel. Do not attempt to reset repeatedly.

9. User Tips

  • For optimal performance, ensure your home's water pressure is within the recommended range.
  • Regularly check the water inlet filter for debris, especially if you notice reduced water flow.
  • Consider the ambient water temperature in your region, as it can affect the heater's performance and the maximum achievable hot water temperature.
  • The intelligent control system and water flow sensor work best with consistent water flow. Avoid frequent on/off cycling of the faucet during use.

10. Warranty and Support

Your Haier EI60C1(W) water heater comes with a 5-year quality assurance service. For any technical support, service requests, or warranty claims, please contact your local Haier service center or the retailer where you purchased the product. Please have your model number and purchase date ready when contacting support.

© 2024 Haier. All rights reserved.


Documents and downloads