1. Product Overview

The DLB-600W ATORCH 40A DC Electronic Load Tester is a versatile and high-precision instrument designed for testing various DC power sources and batteries. It supports multiple discharge modes and offers advanced features like Bluetooth connectivity for remote control and data logging via PC and mobile applications.

Front view of the DLB-600W ATORCH DC Electronic Load Tester
Figure 1: Front view of the DLB-600W ATORCH DC Electronic Load Tester.
Overview of the DLB-600W tester's capabilities
Figure 2: Overview of the DLB-600W tester's capabilities and features.
Video 1: Demonstration of the DLB-600W electronic load tester in operation.

2. Specifications

General Parameters:

  • Brand Name: ATORCH (also XMSJ)
  • Model Number: DLB-600W
  • Type: Electronic Device Battery Tester
  • Origin: Mainland China
  • Certification: CE
  • DIY Supplies: ELECTRICAL
  • Battery Included: No
  • High-concerned chemical: None

Technical Specifications:

  • Power Supply: DC 12V/2A (Note: 150W/180W models use DC12V/1A; 300W/450W/600W models use DC12V/3A)
  • Measuring Voltage Range: 2-200V (step 0.01V)
  • Measuring Current Range: 3mA~40A (step 0.01A, current automatically adjusted according to power limit)
  • Discharge Power: 600W (Voltage * Current < 600W)
  • Discharge Current Limitation: Less than 3A above 200V; Less than 40A at 15V.
  • Display: 2.4-inch HD IPS Color Display (Panel Graphic 240x320 RGB)
  • Connectivity: Bluetooth data transmission (for PC, Android, iOS apps)
  • CPU: 32-bit ARM® Cortex® CPU core
  • Timed Charging: 00H:01S-99H:59S setting
  • Support Bidirectional Current: Yes
  • Support Full Power Cut Off: Yes

Product Model Comparison:

Table comparing different DLB series models
Figure 3: Comparison table for DLB series models, including voltage, current, power, and size.

3. Setup

3.1 Package Contents:

  • DLB-600W Battery Tester (1 pc)
  • DC12V 2A Power Supply (1 pc)
  • 10A Red and Black Alligator Clip Cable (1 set)
  • Temperature Probe (1 pc)
  • Adapter Board (1 pc)
  • US to EU Adapter (1 pc) - Note: Ensure the provided power supply is compatible with your region. If not, a local DC12V 3A power supply is required for 600W models.

3.2 Panel Introduction:

Front and back panel diagram with labeled components
Figure 4: Front and back panel diagram with labeled components for connection and control.
  1. External NTC temperature probe port
  2. Mini USB detection port input
  3. Micro USB detection port input
  4. Type-C USB detection port input
  5. DIY assembly Different power reserve jumper positions (150W/300W/450W/600W)
  6. Voltage/Current/Setting/Adjusting Knob
  7. Instrument operation switch Button (ON/OFF)
  8. Power Switch Button
  9. DC12V 2A Power Supply Input
  10. Bluetooth indicator (Flashing: waiting for connection; Solid: connected)

3.3 Wiring Methods:

Electronic load wiring diagram showing two-wire and four-wire connections
Figure 5: Electronic load wiring diagram for two-wire and four-wire connections.
  • Two-wire wiring method (1): This method is relatively simple and convenient. Connect the load directly to the positive and negative terminals of the device under test.
  • Four-wire wiring method (2): For more accurate voltage measurements, especially with high currents, the four-wire method is recommended. This method separates the voltage measurement lines (V+, V-) from the current lines (A+, A-) to compensate for voltage drop across the wires.

4. Operating Instructions

4.1 Basic Button Operations:

  • Short press "ON/OFF" button: Starts or stops the discharge.
  • Long press "ON/OFF" button: Enters the product background settings.
  • Short press "M" button: Moves the cursor in settings or switches setting columns in the background interface.
  • Long press "M" button: Starts function mode (flashing). Short press "+/-" to select function (CC/CV/CR/CP/BRT/PT). Short press "M" again to switch between Time Discharge and Cut-off Voltage settings.
  • "+" / "-" buttons: Increase/decrease values. Long press for continuous adjustment. When mode is flashing, short press to cycle through options.
  • Long press "+/-" buttons simultaneously: Clears all accumulated data (capacity, time, etc.).

4.2 Discharge Modes:

Display showing various discharge modes: CC, CV, CP, CR, BRT, PT
Figure 6: The tester's display showing different operating modes.
  • CC (Constant Current): Discharges the battery at a constant current. Useful for testing battery capacity or power supply current.
  • CV (Constant Voltage): Discharges while maintaining a constant voltage.
  • CR (Constant Resistance): Discharges with a constant resistance load.
  • CP (Constant Power): Discharges at a constant power. Useful for testing power supplies or equipment that operates at constant power.
  • BRT (Battery Internal Resistance Test): Measures the internal resistance of batteries.
  • PT (Power Performance Test): Intelligent one-key automatic detection for DC power supplies/chargers.

4.3 Specific Test Scenarios:

4.3.1 Battery Capacity Test:

The tester is designed for discharging various batteries (e.g., 18650, car batteries, NiMH, NiCd, LiPo, LiFe, Pb) and performing capacity tests. Use CC mode for this purpose.

Automatic battery internal resistance detection
Figure 7: Automatic detection of battery internal resistance data.

4.3.2 Mobile Power Test:

Supports discharging of mobile power supplies and capacity testing. Connect the mobile power supply to the appropriate input port (Mini USB, Micro USB, or Type-C USB) and use CC mode.

4.3.3 DC Power Supply Performance Test:

The tester supports performance and aging tests of various DC power supplies. Connect the DC power supply to the independent power supply port of the load meter. Use CC or CP mode to precisely adjust current/power and test voltage and rated current. The DC power supply can also be aged for a long time.

Tester connected to a DC power supply for testing
Figure 8: Intelligent one-key automatic detection of DC power supply.

4.3.4 Data Cable/Charger Test:

To test USB data cables or chargers:

  1. Connect the data cable to the corresponding interface of the load tester.
  2. Connect the other end of the data cable to the charger/power source.
  3. Turn on the load in Constant Current (CC) mode.
  4. Adjust the current until the voltage drop is 1V less than the no-load condition. The current value displayed at this point is the current capacity of the data cable.
Testing setup for 10A cable and 3mA battery
Figure 9: Testing setup for 10A experience cable and 3mA battery test. Note: For 2-wire test, do not exceed 10A.

4.4 Current Precision Setting (1mA or 10mA):

To change the current precision:

  1. Long press the "ON/OFF" button to enter the background settings.
  2. Press the "M" button to navigate to item 05: "Precision of current".
  3. Use the "+" or "-" buttons to set the precision to "O10mA" or "1mA".
  4. Tip: The minimum test current is 3mA.

4.5 Intelligent One-Key Automatic Detection (PT Mode):

This mode simplifies testing of chargers and DC power supplies:

  1. Long press the "M" button until the mode bar flashes.
  2. Use the "+/-" buttons to select "PT" mode.
  3. Connect your charger or DC power supply to the tester.
  4. Short press the "ON/OFF" button to start the automatic detection.
  5. The tester will run for a period and then display 4 important numerical results, simplifying complex tests.

5. Maintenance

5.1 Intelligent Temperature Control Fan:

The electronic load features an intelligent temperature control fan. The fan will only start working when a certain temperature is reached. If the starting temperature is not met, it will not operate.

Intelligent temperature control fan settings and operation
Figure 10: Details of the intelligent temperature control fan and its settings.
  • The default startup temperature is 52°C.
  • You can adjust the startup temperature range in the system background between 40°C and 80°C.
  • The fan stops working when the temperature drops by 10°C from its startup temperature. For example, if the startup temperature is set to 40°C, the fan will stop at 30°C.

To adjust the fan start temperature:

  1. Long press the "ON/OFF" button to enter the background settings.
  2. Navigate to the fan control settings using the "M" button.
  3. Use the "+" or "-" buttons to adjust the desired fan start temperature.

6. Troubleshooting and Protection

6.1 Protection Settings:

Protection settings for over power, overcurrent, and over temperature
Figure 11: Visual representation of protection settings.

The device includes several protection mechanisms to ensure safe operation:

  • Overload Protection: Prevents damage from excessive power draw.
  • Overcurrent Protection: Safeguards against currents exceeding safe limits.
  • High Temperature Protection: Shuts down the device if internal temperatures become too high.

If any protection is triggered, the device will typically stop operation and display an error message. Refer to the on-screen prompts for specific error details.

7. Software and App Usage

The DLB-600W tester supports Bluetooth connectivity for remote control and data monitoring via various applications.

Tester connected to PC, iOS, and Android apps via Bluetooth
Figure 12: Wireless Bluetooth connectivity with computer, Android, and iOS applications.

7.2 iOS Mobile App:

Search for "E_test" in the iPhone App Store to download and install. Open the app, click the Bluetooth icon, and select "DL24-BLE" to connect. This enables remote wireless control, measurement functions, real-time discharge status viewing, data cleaning, and power curve analysis.

7.3 Android Mobile App:

Download the app from the provided links or search for "E-test" on Google Play. After installation, open the app and click the Bluetooth icon. Directly select "DL24-BLE" to connect. No separate Bluetooth pairing is required; the app handles the connection directly.

7.4 PC Bluetooth Wireless Online App:

To connect the tester to your computer via Bluetooth:

  1. First, add the Bluetooth device "DL24-SPP" to your computer's serial port devices.
  2. Download the corresponding PC APP software from the provided link.
  3. Open the software (no installation needed) and select the Bluetooth serial port model you just added.
  4. You can now use the tester online with your PC.

8. User Tips

  • For precise measurements, especially with higher currents, always use the 4-wire wiring method to minimize voltage drop effects.
  • Remember that the discharge current is limited by the maximum power. For example, above 200V, the current will be less than 3A, and at 15V, it will be less than 40A.
  • When testing data cables, ensure the voltage drop is 1V less than the no-load condition to accurately determine the cable's current capacity.
  • Utilize the intelligent temperature control fan settings to optimize cooling based on your testing environment and load.
  • If you encounter issues, check the protection settings and ensure the device is not operating beyond its specified limits.

9. Warranty and Support

This product is manufactured under strict quality control. For any technical support or inquiries, please refer to the contact information provided by your seller or the official product page. Ensure you have your product model number (DLB-600W) ready when seeking support.

The manufacturer is committed to providing quality testing equipment. Please ensure the product meets your needs before use. If you have questions regarding usage, please contact customer service.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.