1. Introduction
The Jesverty SPS-6020/8015 series is a high-precision programmable DC benchtop power supply designed for various applications including laboratories, educational sites, factory manufacturing tests, maintenance repairs, battery charging, anodizing, and electronic DIY projects. It features advanced encoder adjustment knobs for precise voltage and current settings, an output ON/OFF button for convenience, and multiple protection functions to ensure safe operation.
Key features include:
- Encoder Adjustment Knobs for precise 0.01V/0.01A resolution.
- Output ON/OFF Button for easy control without disconnecting loads.
- Over-Voltage Protection (OVP) and Over-Current Protection (OCP).
- Temperature-regulated cooling fan for efficient heat dissipation.
- Compact and lightweight design, measuring approximately 290mm (D) x 210mm (W) x 80mm (H) and weighing about 3.0kg (6.4lbs).
2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always connect the power supply to a grounded outlet.
- Do not operate the device in wet or damp conditions.
- Ensure proper ventilation to prevent overheating.
- Do not open the casing; there are no user-serviceable parts inside.
- Disconnect power before making any connections or adjustments to the output terminals.
- Verify voltage and current settings before applying power to a load.
- Use appropriate cables and connectors for your application.
3. Product Overview
3.1 Front Panel

Figure 1: Front and Rear Panel Overview
- Power Switch: Main power ON/OFF.
- 4-Digit LED Display: Shows voltage and current readings.
- RMT/ACM/OCP/OVP/OUT LEDs: Status indicators for various functions.
- IDS/CC/OCP/OVP/CV/OUT Buttons: Control buttons for different modes and protections.
- Current Adjustment Knob: Encoder knob for setting output current.
- Voltage Adjustment Knob: Encoder knob for setting output voltage.
- Aux Output (5A MAX): Auxiliary output terminals.
- Main Output Terminals: Red for positive, Black for negative.
3.2 Rear Panel
- Intelligent Cooling Fan: Automatically adjusts speed based on temperature.
- FUSE: Overcurrent protection for the input.
- AC Input Socket: For connecting the power cord.
3.3 Dimensions and Weight

Figure 2: Dimensions and Weight
Approximate Dimensions: 290mm (D) x 210mm (W) x 80mm (H) / 11.41 x 8.26 x 3.15 inches
Approximate Weight: 3.0kg / 6.4lb
4. Setup
- Unpacking: Carefully remove the power supply and all accessories from the packaging. Verify that all items listed in the 'Items you get' section are present.
- Power Connection: Connect the provided power cord to the AC input socket on the rear panel and then to a suitable grounded power outlet. Ensure the power source matches the voltage requirements of your unit (e.g., US-110V, EU-220V, UK-220V, AU-220V).
- Initial Power On: Flip the 'POWER' switch on the front panel to the 'ON' position. The LED display should light up.
- Output Connections: For main output, connect your load to the red (+) and black (-) terminals. For auxiliary output, use the dedicated 5A MAX terminals. Ensure all connections are secure before proceeding.
5. Operating Instructions
This section details the operation of your Jesverty power supply. For a visual guide, please refer to the demonstration video below.
Video 1: Demonstration of Power Supply Controls
5.1 Power ON/OFF
- To turn the power supply ON, press the 'POWER' button.
- To turn the power supply OFF, press the 'POWER' button again.
5.2 Setting Voltage and Current
The power supply uses encoder adjustment knobs for precise control.

Figure 3: Encoder Knob Operation
- Voltage Adjustment:
a. Press the 'VOLTAGE' knob to select the digit on the voltage display you wish to change.
b. Rotate the 'VOLTAGE' knob to adjust the value of the selected digit. - Current Adjustment:
a. Press the 'CURRENT' knob to select the digit on the current display you wish to change.
b. Rotate the 'CURRENT' knob to adjust the value of the selected digit.
5.3 Output ON/OFF Control
- To turn the output ON, press the 'OUT' button. The 'OUT' LED will illuminate.
- To turn the output OFF, press the 'OUT' button again. The 'OUT' LED will turn off.
5.4 Over-Voltage Protection (OVP) Setup
- Press the 'OVP' button to enter the OVP configuration interface. The display will show 'OFF' or 'ON' and the current OVP trip point.
- To enable OVP, press and rotate the 'CURRENT' knob to set the OVP status to 'ON'.
- Use the 'VOLTAGE' knob to set the desired OVP trip point (e.g., 40.00V).
- Press the 'OVP' button again to return to the main interface. The 'OVP' LED will be lit, indicating OVP is active.
- If the output voltage exceeds the set OVP trip point, the 'OVP' LED will flash, and the output will be disabled.
- To disable OVP, press the 'OVP' button, then press and rotate the 'CURRENT' knob to set the OVP status to 'OFF'. Press 'OVP' again to exit.
5.5 Over-Current Protection (OCP) Setup
- Press the 'OCP' button to enter the OCP configuration interface. The display will show 'OFF' or 'ON' and the current OCP trip point.
- To enable OCP, press and rotate the 'CURRENT' knob to set the OCP status to 'ON'.
- Use the 'VOLTAGE' knob to set the desired OCP trip point (e.g., 10.00A).
- Press the 'OCP' button again to return to the main interface. The 'OCP' LED will be lit, indicating OCP is active.
- If the output current exceeds the set OCP trip point, the 'OCP' LED will flash, and the output will be disabled.
- To disable OCP, press the 'OCP' button, then press and rotate the 'CURRENT' knob to set the OCP status to 'OFF'. Press 'OCP' again to exit.
6. Specifications
| Feature | Specification |
|---|---|
| Brand Name | Jesverty |
| Model Number | SPS-6020/8015 |
| Power Output | 1200W |
| Voltage Range (SPS-6020) | 0-60V |
| Current Range (SPS-6020) | 0-20A |
| Voltage Range (SPS-8015) | 0-80V |
| Current Range (SPS-8015) | 0-15A |
| Display | 4-Digit LED |
| Resolution | 0.01V / 0.01A |
| Current Type | AC |
| Phase | Single Phase |
| Number of Sockets | 1 |
| Dimensions (L x W x H) | 290mm x 210mm x 80mm (11.41 x 8.26 x 3.15 inches) |
| Weight | Approx. 3.0kg (6.4lbs) |
| Origin | Mainland China |
6.1 Model Variants
The Jesverty 1200W series is available in different voltage/current configurations:
SPS-6020: 0-60V, 0-20A, 1200W
SPS-8015: 0-80V, 0-15A, 1200W
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the exterior of the power supply. Do not use abrasive cleaners or solvents.
- Ventilation: Ensure that the ventilation openings on the device are not blocked. Maintain adequate space around the unit for proper airflow.
- Storage: When not in use for extended periods, store the power supply in a cool, dry place, away from direct sunlight and extreme temperatures.
- Fuse Replacement: If the fuse blows, replace it with one of the same type and rating. Refer to the specifications for the correct fuse type.
8. Troubleshooting
- No Power:
a. Check if the power cord is securely connected to both the power supply and the wall outlet.
b. Ensure the main power switch is in the 'ON' position.
c. Check the fuse on the rear panel. Replace if blown. - No Output Voltage/Current:
a. Ensure the 'OUT' button is pressed and its LED is illuminated.
b. Check if OVP or OCP protection has been triggered (OVP/OCP LEDs flashing). If so, clear the fault condition and reset the protection or disable it temporarily for testing.
c. Verify that the voltage and current settings are not set to zero. - OVP/OCP LED Flashing:
a. This indicates that the Over-Voltage Protection or Over-Current Protection has been activated.
b. Reduce the output voltage or current setting, or check your load for faults (e.g., short circuit, excessive current draw).
c. To reset, turn off the output using the 'OUT' button, correct the issue, and then turn the output back on. - Overheating:
a. Ensure the cooling fan is operating and not obstructed.
b. Check for adequate ventilation around the unit.
9. User Tips
- Pre-set Limits: Always set your desired voltage and current limits before connecting a new or sensitive load to prevent accidental damage.
- Load Connection: Connect the load to the output terminals only after the power supply is turned on and the desired voltage/current limits are set, but before enabling the output.
- Auxiliary Output: Remember the auxiliary output is limited to 5A MAX. Do not exceed this limit.
- Protection Features: Utilize the OVP and OCP features to protect your circuits and the power supply from unexpected conditions.
10. Warranty and Support
For specific warranty details and terms, please refer to the documentation provided at the time of purchase or contact your seller directly.
For technical support, questions, or assistance with your Jesverty power supply, please contact Jesverty Customer Service via the platform's messaging system or email. Please have your model number and purchase details ready when contacting support.