meterk FY168S

Contents

Digital Multimeter FY168S Instruction Manual

Model: FY168S | Brand: Meterk

1. Introduction

This manual provides essential information for the safe and effective use of your Meterk FY168S Digital Multimeter. This portable, multifunctional device features a color display, automatic range selection, and anti-burning protection, making it suitable for various electrical measurements including AC/DC voltage, AC/DC current, capacitance, resistance, frequency, duty cycle, diode testing, and temperature measurement.

Please read this manual thoroughly before operation and keep it for future reference.

2. Safety & Warnings

Important Safety Information:

  • Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.
  • Warning: Keep the device and its cord out of reach of children under 3 years old.
  • Keep away from children unless supervised by an adult.
  • Do not use this product for purposes other than its intended use.
  • Inspect the product before each use; do not use if damaged.
  • Follow installation and operation guidelines to avoid injury.
  • Do not expose to water or moisture.
  • Handle with care to avoid cuts or injuries.

This product must comply with all applicable safety and regulatory requirements in the market where it is sold. Always ensure proper handling and usage to prevent hazards.

3. Package Contents

Verify that all items are present in the package:

  • 1 x Digital Multimeter (FY168S)
  • 2 x Test Leads (Red and Black)
  • 1 x Temperature Probe
  • 1 x USB Type-C Charging Cable
  • 1 x Carrying Case
  • 1 x User Manual (this document, or a printed version)
Meterk FY168S Digital Multimeter with included accessories: test leads, temperature probe, USB cable, and carrying case.
Figure 3.1: FY168S Multimeter and Accessories

4. Product Overview

Familiarize yourself with the components of your FY168S Digital Multimeter:

Labeled diagram of the FY168S Multimeter showing: Non-contacting voltage sensing area, Flashlight, Color Reverse Display Screen, Silicone sheath, High sensitivity I-Neutral live wire judgement, Capacitors and diodes, ON OFF button, Automatic function mode switch, Manual function mode switch, Light, Temperature, Backlight, Current meter probe socket, Black test pen socket, Red test pen socket.
Figure 4.1: FY168S Multimeter Labeled Diagram
  • Non-contacting voltage sensing area: Used for V Alert mode.
  • Flashlight: Illuminates the work area.
  • Color Reverse Display Screen: Displays measurement readings.
  • Silicone sheath: Provides protection and grip.
  • High sensitivity I-Neutral live wire judgement: For live wire detection.
  • Capacitors and diodes: Indicators for respective measurement modes.
  • ON OFF button: Powers the device on or off.
  • Automatic function mode switch (AUTO SEL): Engages automatic measurement mode.
  • Manual function mode switch: Allows manual selection of functions.
  • Light/Temperature/Backlight buttons: Controls flashlight, temperature display, and screen backlight.
  • Current meter probe socket: Input for current measurements.
  • Black test pen socket (COM): Common ground connection for test leads.
  • Red test pen socket (VΩLive): Positive input for voltage, resistance, and live wire detection.

5. Initial Setup

5.1. Charging the Battery

The FY168S multimeter features a built-in 400mAh rechargeable battery. Before first use, or when the battery indicator is low, charge the device using the provided Type-C USB cable.

  1. Connect the Type-C end of the USB cable to the multimeter's charging port.
  2. Connect the other end of the USB cable to a standard USB power adapter (not included) or a computer USB port.
  3. The charging indicator on the multimeter will show the charging status.
The FY168S multimeter being charged via a USB-C cable connected to a power strip.
Figure 5.1: Charging the Multimeter

5.2. Connecting Test Leads

For most measurements, you will need to connect the test leads:

  1. Insert the black test lead into the 'COM' (Common) socket.
  2. Insert the red test lead into the 'VΩLive' socket for voltage, resistance, and live wire measurements.
  3. For current measurements, insert the red test lead into the 'Current meter probe socket'. The multimeter will automatically recognize and activate current measurements upon insertion.
Close-up of the multimeter's input jacks with a red test lead inserted into the current measurement socket, illustrating automatic current activation.
Figure 5.2: Automatic Current Activation with Test Lead

6. Operating Modes

6.1. Smart Mode Switching (Auto Range)

The FY168S features intelligent overload safety and automatically identifies settings at startup. It operates in auto-range mode by default, simplifying measurements.

  • Press the 'AUTO SEL' button to toggle between automatic recognition and manual function selection.
  • In automatic mode, the meter will attempt to detect the type of measurement (voltage, resistance, continuity, etc.) and display the reading.
The FY168S multimeter displaying a reading, with text indicating 'Smart Mode Switching' and its automatic recognition capabilities.
Figure 6.1: Smart Mode Switching in Action

6.2. Comprehensive Temperature Measurement

The multimeter can measure temperatures from 0℃ to 1000℃ using the included temperature probe.

  1. Connect the temperature probe to the appropriate input sockets (refer to the product overview diagram).
  2. Select the temperature measurement mode using the manual function switch or allow auto-selection.
  3. Place the tip of the temperature probe in contact with the object or environment to be measured.
  4. The temperature reading will be displayed on the screen.
The FY168S multimeter measuring the temperature of liquid in a cup using its temperature probe.
Figure 6.2: Temperature Measurement

6.3. Circuit Breakpoint Detection (V Alert)

This non-contacting voltage detection mode helps locate circuit breakpoints efficiently.

  • Activate the V Alert mode.
  • Move the top of the multimeter (non-contacting voltage sensing area) along the electrical wire.
  • The device will indicate the presence of voltage, helping to trace and identify faults.
  • Sensitivity can be adjusted (HI for high sensitivity, LO for low sensitivity).
The FY168S multimeter being used to detect a circuit breakpoint in an electrical panel, demonstrating the V Alert feature.
Figure 6.3: Circuit Breakpoint Detection

6.4. Live Wire Safety Check (LIVE Mode)

Use the LIVE mode to accurately determine live and neutral wires with a single test probe.

  • Ensure the red test lead is connected to the 'VΩLive' socket.
  • Select the LIVE mode.
  • Touch the red test probe to the wire or terminal. The multimeter will indicate if it's a live wire, and a 'fire wire reminder' will alert you to potential hazards.

6.5. Other Functions

The multimeter supports various other functions including:

  • AC/DC Voltage measurement
  • AC/DC Current measurement
  • Capacitance measurement
  • Resistance measurement
  • Frequency and Duty Cycle measurement
  • Diode testing
  • Continuity (On/Off Buzzer) testing

Use the manual function mode switch to cycle through these functions as needed. The 'Light', 'Temperature', and 'Backlight' buttons control the flashlight, switch between temperature units, and activate the screen backlight respectively.

7. Specifications

FeatureSpecification
ModelFY168S
Brand Namemeterk
Work ModeAutomatic, Manual (Auto Range)
ScreenColor Reverse Display Screen
Silicone SheathSupported
AC Voltage60mV-620V (manual), 0.8-620V (automatic), ± (1.2% reading+5), 10-620V (VFC variable frequency voltage)
DC Voltage60mV-620V (manual), 0.8-620V (automatic), ± (0.8% reading+3)
AC Current1mA-610mA, ± (1.5% reading+3) (automatically recognized by plug probe)
DC Current1mA-610mA, ± (1.5% reading+3) (automatically recognized by plug probe)
Capacitance0.5uF-60mF, ± (4.5% reading+10)
Resistance10Ω-60MΩ, ± (4.5% reading+10)
Frequency, Duty CycleSupported
DiodeSupported
On/Off BuzzerSupported
Live Neutral Wire Live Wire JudgmentSupported
V Alert Non Contacting Voltage InductionSensitivity adjustable (HI high sensitivity, LO low sensitivity)
Line Breakpoint JudgmentJudgment in V Alert mode
Temperature Measurement0℃ to 1000℃
Environmental Temperature Range0℃ to 50℃
Automatic ShutdownApproximately 15 minutes of inactivity
Power Supply3.7V 400mAh rechargeable battery (built-in)
DIY SuppliesElectrical
OriginMainland China
Dimensions (Approx.)146mm (L) x 44mm (W) x 25.2mm (D)
Diagram showing the dimensions of the FY168S multimeter: 146mm / 5.75in in length, 44mm / 1.73in in width, and 25.2mm / 0.99in in depth.
Figure 7.1: Multimeter Dimensions

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the multimeter. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in its carrying case in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
  • Test Leads: Inspect test leads for any damage (cracks, frayed insulation) before each use. Replace damaged leads immediately.

9. Troubleshooting

If you encounter issues with your multimeter, try the following basic troubleshooting steps:

  • No Display/Power On: Ensure the battery is charged. Connect the USB-C cable and charge for at least 30 minutes.
  • Incorrect Readings:
    • Check that test leads are correctly inserted into the appropriate sockets for the desired measurement.
    • Verify that the correct measurement mode (Auto or Manual) is selected.
    • Ensure good contact between the test probes and the circuit/component being measured.
  • Automatic Shutdown: The device has an automatic shutdown feature after approximately 15 minutes of inactivity to conserve battery. Press any button to reactivate.

For persistent issues, please refer to the official PDF manual or contact customer support.

10. User Tips

  • Always start with the 'AUTO SEL' mode for general measurements; the multimeter will intelligently detect the parameter.
  • Utilize the built-in flashlight for better visibility in dimly lit work areas.
  • When performing temperature measurements, ensure the probe is securely connected and in good thermal contact with the target.

11. Warranty & Support

For warranty information and customer support, please contact the seller or the manufacturer directly. The manufacturer details are:

Manufacturer: Feiruilande Shenzhen Shangmao Co., Ltd.
Address: CN-3B01-50, Building A1, 1983 Creative Town, No. 29, Nanxin Street, Nanling Village, Nanwan Street, Longgang District, Shenzhen
Tel: 86-13927483703

EU Authorized Representative: SOLID AUTHORITY LIMITED
EU Representative Address: 51 Bracken Road, Sandyford, Dublin 18, D18 CV48, Ireland

Please retain your proof of purchase for any warranty claims.

12. Additional Resources

An official user manual in PDF format is available for download. This document may contain more detailed instructions and diagrams.

Download PDF Manual: Click here to view/download the User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.