SUOER ST-MP60

Contents

SUOER ST-MP60 Series MPPT/PWM Intelligent Solar Charge Controller User Manual

Model: ST-MP60 Series

For 12V, 24V, and 48V Solar Power Systems

1. Introduction

The SUOER ST-MP60 series intelligent solar charge controller is designed to efficiently manage power flow from your solar panels to your battery bank and DC loads. Utilizing advanced Maximum Power Point Tracking (MPPT) technology, it ensures optimal energy harvesting from your photovoltaic system. This manual provides essential information for the safe and effective installation, operation, and maintenance of your solar charge controller.

SUOER MPPT Solar Charge Controller ST-MP60-II

Figure 1: SUOER MPPT Solar Charge Controller ST-MP60-II

2. Safety Precautions

Please observe the following safety guidelines to prevent injury and damage to the controller or other components:

  • Ensure proper wiring and connections. Incorrect polarity can cause damage.
  • Always connect the battery to the controller first, then the solar panel, and finally the DC load. Disconnect in reverse order.
  • Use copper cables with a cross-sectional area of at least 10 square millimeters to ensure safe and efficient operation.
  • The controller is equipped with multiple protection functions, including:
    • Short Circuit Protection
    • Over Discharger Protection
    • Over Voltage Protection
    • Over Charge Protection
    • Over Temperature Protection
    • Solar Panel Reverse Polarity Protection
  • Do not attempt to disassemble or repair the controller yourself. Refer to qualified personnel for service.
Protection Functions Overview

Figure 2: Overview of Controller Protection Functions

3. Product Components and Features

The SUOER ST-MP60 series controller features a robust design with user-friendly interfaces:

3.1 Physical Overview

Front View of SUOER ST-MP60 Solar Charge Controller

Figure 3: Front View of the Controller

Bottom View with Wiring Terminals

Figure 4: Bottom View with Wiring Terminals

Top View with Cooling Fan

Figure 5: Top View with Cooling Fan

3.2 Panel Part Specification

Panel Part Specification and Controls

Figure 6: Front Panel Layout and Controls

  1. LCD Display: Shows system status and parameters.
  2. Charging indicator light: Indicates charging status.
  3. Function Menu: Accesses various settings.
  4. Down Button: Navigates down through menu options or decreases values.
  5. Wiring Plate: Terminal block for connections.
  6. Up Button: Navigates up through menu options or increases values.
  7. Enter Button: Confirms selections or enters menu.
  8. DC Load indicator light: Indicates DC load status.

3.3 Key Features

  • MPPT automatic maximum power point tracking for efficient charging.
  • Supports 12V/24V/48V battery systems with automatic recognition or manual setting.
  • Three-stage charging method: constant current charging (MPPT), equalizing charging, and float charging.
  • Integrated clock timing function, light control mode, and time control mode.
  • Backlit LCD display for clear visibility of system parameters.
  • Full metal shell with top temperature control radiator and aluminum heat sink fins for good heat dissipation and low noise.

4. Installation and Wiring

Follow these steps for proper installation and wiring of your solar charge controller:

4.1 Mounting Location

  • Mount the controller in a cool, dry, and well-ventilated area.
  • Ensure there is sufficient space around the controller for proper airflow, especially around the cooling fan.
  • Avoid direct sunlight, high temperatures, and moisture.

4.2 Wiring Connections

Refer to the connection diagram below for correct wiring. Always connect in the specified order:

  1. Connect the Battery: Connect the battery to the controller's battery terminals (marked 'BATTERY'). Ensure correct polarity (+ to + and - to -). This step is crucial for the controller to detect the system voltage.
  2. Connect the Solar Panel: Connect the solar panel(s) to the controller's solar panel terminals (marked 'SOLAR PANEL'). Ensure correct polarity.
  3. Connect the DC Load: Connect your DC loads to the controller's DC load terminals (marked 'DC LOAD'). Ensure correct polarity.

Important: Disconnect components in the reverse order: DC load, then solar panel, then battery.

ST-MP-SERIES Connection Diagram

Figure 7: Typical ST-MP-SERIES Connection Diagram

4.3 Cable Specifications

For optimal performance and safety, use copper cables with a cross-sectional area of at least 10 square millimeters.

5. Operation

Once installed, the controller will automatically detect the system voltage (12V/24V/48V) or allow manual setting. The LCD display provides real-time information about your solar system.

5.1 LCD Display and Navigation

The backlit LCD display shows critical information such as solar power, load level, battery voltage/capacity, charging current, and fault conditions. Use the 'Up', 'Down', and 'Enter' buttons to navigate through the menu and adjust settings.

5.2 Charging Modes

The controller employs a three-stage charging process to optimize battery life and performance:

  • Constant Current Charging (MPPT): The controller tracks the maximum power point of the solar panel to deliver the maximum possible current to the battery.
  • Equalizing Charging: Periodically applies a higher voltage to ensure all cells in the battery are fully charged and balanced.
  • Float Charging: Maintains the battery at a full charge by providing a small, constant voltage, preventing overcharging.

5.3 Control Functions

The controller offers programmable control functions:

  • Clock Timing Function: Allows for time-based control of loads.
  • Light Control Mode: Automatically turns loads on/off based on ambient light levels.
  • Time Control Mode: Sets specific on/off times for connected loads.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your solar charge controller:

  • Cleanliness: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
  • Connection Checks: Periodically inspect all wiring connections to ensure they are tight and free from corrosion.
  • Ventilation: Ensure that the cooling fan and ventilation openings are not obstructed to prevent overheating.
  • Environmental Conditions: Verify that the operating environment remains within the specified temperature and humidity ranges.

7. Troubleshooting

The controller is designed with various protection features to prevent common issues. If you encounter a problem, check the following:

  • No Display/Power: Check battery connections and voltage. Ensure the battery is connected first.
  • No Charging: Verify solar panel connections and ensure sufficient sunlight. Check for reverse polarity on solar panel input.
  • Load Not Working: Check DC load connections and ensure the load is within the controller's capacity. Verify load control settings (light/time mode).
  • Overheating: Ensure proper ventilation and that the cooling fan is operating. Reduce load if necessary.
  • Error Codes/Indicators: Refer to the LCD display for any specific error messages or indicator light patterns, which can help diagnose the issue.
  • Protection Activated: If any of the built-in protections (e.g., short circuit, over-discharge, over-charge) are triggered, the controller will automatically shut down or limit operation. Identify and resolve the underlying cause before resuming normal operation.

8. Specifications

SUOER ST-MP60 Series Dimensions

Figure 8: Controller Dimensions (300mm x 230mm x 106mm)

FeatureDescriptionST-MP30AST-MP40AST-MP60A
Charging ModeMPPT automatic maximum power point tracking
Charging MethodThree stages: constant current charging (MPPT), Equalizing charging, float charging
System Type12V/24V/48VAutomatical recognition / Manual setting
System Identification Voltage Range12V systemDC9V-DC15V
24V systemDC18V-DC30V
48V systemDC36V-DC60V
Quiescent Dissipation12V/24V/48V≤2W
Overall Unit Efficiency12V/24V/48V≥96.5%
Photovoltaic Module Utilization Ratio12V/24V/48V≤99%
MPPT Working Voltage Range12V systemDC18V-DC150V
24V systemDC30V-DC150V
48V systemDC65V-DC150V
Maximum Solar Input Power12V system450W570W900W
24V system750W1130W1700W
48V system1500W2270W3400W
Max Input Voltage of Solar Panel150V
DisplayBacklit LCD display
FunctionClock timing, light control mode, time control mode
Control MethodIntelligent control
Mechanical Protection TypeIP21
CertificationISO

9. User Tips

  • Sizing Your System: Always ensure that the maximum solar input power of your controller matches or exceeds the total wattage of your solar panels. Similarly, ensure the controller's current rating is appropriate for your battery bank and expected loads.
  • Battery Compatibility: While the controller supports 12V/24V/48V systems, ensure your battery type (e.g., lead-acid, lithium-ion) is compatible with the controller's charging algorithms. Consult the controller's settings for battery type selection if available.
  • Monitoring: Regularly check the LCD display for system performance and any alerts. This helps in early detection of potential issues.

10. Warranty and Support

10.1 Warranty Period

This product comes with a warranty period of twelve months from the date of purchase. Please retain your proof of purchase for warranty claims.

10.2 Technical Support

For technical assistance or warranty inquiries, please contact your retailer or the manufacturer's customer service. Provide your product model and a detailed description of the issue for efficient support.

11. Product Video Showcase

Play video
Watch video online

Video 1: SUOER ST-MP60 Solar Charge Controller Product Showcase


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.