1. Introduction
The RIGOL DM3058 and DM3068 are high-performance 5½ and 6½-digit True RMS (TRMS) Digital Multimeters designed to meet the needs of high-precision, multifunction, and automatic measurement applications. These instruments offer excellent performance, abundant features, and are suitable for various fields including research and development, education, industrial electronics, and automotive industries.
The DM3058 provides 5½ digits readings resolution and up to 123 readings/second measurement speed. The DM3068 offers 6½ digits readings resolution and up to 10,000 readings/second measurement speed.
2. Product Overview
2.1 Front Panel
2.2 Rear Panel
2.3 Included Accessories
3. Setup
3.1 Power Connection
- Ensure the power switch on the rear panel is in the OFF position.
- Verify the correct voltage setting for your region (AC 100-120V or AC 200-240V) using the selector near the power input on the rear panel (refer to Figure 3).
- Connect the provided power cord to the AC power input on the rear panel and then to a suitable AC power outlet.
3.2 Test Lead Connection
For most measurements, connect the red test lead to the VΩHz input terminal and the black test lead to the COM input terminal on the front panel. For current measurements, connect the red test lead to the A or mA input terminal as appropriate.
3.3 Interface Connections
The multimeter supports various interfaces for remote control and data transfer:
- USB Host: For connecting USB storage devices (front panel).
- USB Device: For connecting to a PC (rear panel).
- LAN (Ethernet): For network connectivity (rear panel).
- GPIB: General Purpose Interface Bus for instrument control (rear panel).
- RS-232: Serial communication interface (rear panel).
Connect the appropriate cables to the respective ports on the rear panel as needed for your application.
4. Operating Instructions
The multimeter features an intuitive front panel with dedicated function keys and a navigation cluster. Refer to Figure 1 and Figure 2 for key locations.
4.1 Basic Measurement Functions
Press the corresponding function key to select the desired measurement mode:
- DCV (DC Voltage): Measures direct current voltage.
- ACV (AC Voltage): Measures alternating current voltage (True RMS).
- DCI (DC Current): Measures direct current.
- ACI (AC Current): Measures alternating current (True RMS).
- Ω (Resistance): Measures resistance.
- Cap (Capacitance): Measures capacitance.
- Freq (Frequency): Measures frequency.
- Diode: Performs diode test.
- Continuity: Checks for circuit continuity with an audible tone.
- Sensor (Temperature): Supports various temperature sensors (Thermocouple, RTD).
4.2 Advanced Features
- Double Display: Simultaneously displays two measurement results.
- Preset Mode: Save and recall up to 10 groups of preset configurations.
- Any Sensor Measurement: Supports 6 kinds of sensors (DCV, DCI, Freq, 2WR, 4WR, and TC).
- Math Function: Analyze measurements using various math operations (e.g., Min/Max/Average, dBm, dB, Hold, Histogram, Standard deviation).
- Statistic Function: Provides statistical analysis of measurement data.
- Histogram Display: Visualizes data distribution over time.
- Trend Display: Graphs measurement trends over a long duration.
- LXI & Web Control: DM3058 is LXI Class C compliant, allowing web-based control and monitoring.
- UltraSensor Software: Provides a user-friendly interface for sensor measurements, data management, and real-time monitoring.
5. Maintenance
5.1 General Care and Cleaning
- Keep the multimeter clean and dry. Use a soft, damp cloth for cleaning the exterior. Do not use abrasive cleaners or solvents.
- Ensure no liquids enter the instrument.
- Store the device in a clean, dust-free environment when not in use.
5.2 Fuse Replacement
The multimeter contains fuses to protect against overcurrent. If the instrument fails to power on or a current measurement range is inoperative, check the fuses.
- Power Fuse: Located on the rear panel, integrated with the AC power input module (refer to Figure 3). Ensure the instrument is disconnected from the power supply before attempting to replace.
- Current Input Fuses: A 200mA current input fuse is located on the rear panel. Internal fuses for 2A and 10A ranges are also present and may require professional service for replacement.
Always replace fuses with the specified type and rating to ensure proper protection and operation.
6. Troubleshooting
This section provides solutions to common issues. If the problem persists, contact RIGOL customer support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Instrument does not power on. | Power cord not connected, power fuse blown, incorrect voltage setting. | Check power cord connection. Verify voltage selector. Replace power fuse if blown (refer to Section 5.2). |
| No reading or incorrect reading in current mode. | Test leads connected to wrong terminals, current input fuse blown. | Ensure test leads are connected to the correct current input (A or mA) and COM terminals. Check and replace current input fuses (refer to Section 5.2). |
| Display shows "OL" (Overload). | Input signal exceeds selected range, open circuit. | Select a higher measurement range. Check for open circuits in the test setup. |
| Unstable or noisy readings. | External noise interference, poor test lead connection. | Ensure proper shielding. Use shorter test leads. Check for loose connections. |
7. Specifications
7.1 General Specifications
7.2 DC Characteristics
7.3 AC Characteristics
7.4 Capacitance Characteristics
7.5 Measurement Rate & Other Characteristics
7.6 SFDR & SINAD
8. User Tips
No specific user tips from reviews or Q&A were provided for this product. General best practices for digital multimeters include:
- Always ensure the correct function and range are selected before making a measurement to prevent damage to the instrument or circuit.
- When measuring current, always connect the multimeter in series with the load.
- When measuring voltage, always connect the multimeter in parallel with the component.
- For sensitive measurements, allow the instrument to warm up for the specified time (e.g., 30 minutes) to achieve optimal accuracy.
9. Warranty and Support