FLUKE 1508

Contents

Fluke 1508 Digital Insulation Multimeter User Manual

Model: F1508

1. Introduction

The Fluke 1508 is a powerful handheld digital insulation multimeter designed for precision electrical testing. It features a Chinese interface and an LCD display, making it a reliable tool for various applications, including testing cables, motors, and transformers.

This tester incorporates "one-key" computing functions to automatically calculate polarization index and dielectric absorption rate, minimizing manual calculation errors. Its robust, reliable, and user-friendly design aims to enhance efficiency in your work.

Video: Overview of the Fluke 1508 Digital Insulation Multimeter.

Front view of the Fluke 1508 Digital Insulation Multimeter, displaying a measurement of 48.2 MΩ and showing Chinese labels on buttons.

Image: Front view of the Fluke 1508 Digital Insulation Multimeter, displaying a measurement of 48.2 MΩ and showing Chinese labels on buttons.

2. Safety Information

Always adhere to safety precautions when operating the Fluke 1508. Failure to do so may result in injury or damage to the device.

  • Ensure the device is turned off before connecting or disconnecting test leads.
  • Do not use the device if it appears damaged or is operating abnormally.
  • Verify the correct function and range settings before making any measurements.
  • Observe all local and national safety codes.
  • The device is rated for CAT IV 600 V equipment requirements.

3. Setup

3.1 Battery Installation

The Fluke 1508 requires four AA-size batteries (NEDA 15A or IEC LR6). Batteries are not included in the package.

  1. Locate the battery compartment on the back of the device.
  2. Use a screwdriver to open the battery compartment cover.
  3. Insert four AA batteries, ensuring correct polarity.
  4. Securely close the battery compartment cover.
Rear view of the Fluke 1508 Digital Insulation Multimeter, showing the battery compartment.

Image: Rear view of the Fluke 1508, indicating the battery compartment.

3.2 Connecting Test Leads

  1. Ensure the multimeter is turned off.
  2. Connect the red test lead to the VΩ terminal.
  3. Connect the black test lead to the COM terminal.
  4. Ensure connections are firm before proceeding with measurements.
Fluke 1508 with test leads and user manual.

Image: Fluke 1508 with test leads connected.

4. Operating Instructions

4.1 Power On/Off

Rotate the central dial from 'OFF' to any desired measurement function to power on the device. Rotate back to 'OFF' to power off.

4.2 Function Selection

The rotary dial allows selection of various measurement functions, including:

  • Insulation Resistance (MΩ, GΩ)
  • AC/DC Voltage (V)
  • Resistance (Ω)

The buttons on the device, though labeled in Chinese, correspond to functions such as 'Test', 'Save', 'Compare', and 'Clear'. Refer to the user tips section for guidance on the Chinese interface.

Front view of the Fluke 1508 Digital Insulation Multimeter.

Image: Front view of the Fluke 1508, showing the rotary dial and display.

4.3 Insulation Resistance Measurement

  1. Rotate the dial to the Insulation Resistance function (indicated by MΩ/GΩ).
  2. Select the desired test voltage (50 V, 100 V, 250 V, 500 V, or 1000 V).
  3. Connect the test leads to the circuit or component under test.
  4. Press the 'Test' button (测试) to initiate the measurement.
  5. The device will automatically discharge when C = 1 μF or more, with a discharge time of less than 0.5 seconds.
  6. The device features a live circuit detection function; if it detects a voltage greater than 30 V before initialization, testing will be inhibited.

4.4 AC/DC Voltage Measurement

  1. Rotate the dial to the AC/DC Voltage function (indicated by V).
  2. Connect the test leads across the points where voltage is to be measured.
  3. Read the voltage value on the display.

4.5 Advanced Functions

The Fluke 1508 includes "one-key" computing functions for Polarization Index (PI) and Dielectric Absorption Ratio (DAR). Consult the full manufacturer's manual for detailed instructions on utilizing these advanced features.

5. Maintenance

5.1 Cleaning

Wipe the device with a damp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is dry before storage or next use.

5.2 Battery Replacement

When the low battery indicator appears on the display, replace all four AA batteries promptly to ensure accurate measurements and continuous operation. Follow the battery installation steps outlined in Section 3.1.

5.3 Storage

Store the Fluke 1508 in a dry environment within the specified storage temperature range of -40 °C to 60 °C (-40 °F to 140 °F). Remove batteries if storing for extended periods to prevent leakage.

6. Troubleshooting

  • No Display/Device Not Powering On: Check battery installation and ensure batteries are fresh. Verify the rotary dial is set to a function other than 'OFF'.
  • Inaccurate Readings: Ensure test leads are properly connected and not damaged. Check for external interference. Verify the correct function and range are selected for the measurement.
  • Testing Inhibited: If the device detects a live circuit with voltage greater than 30 V before an insulation test, it will inhibit the test for safety. Ensure the circuit is de-energized before attempting insulation tests.
  • Buttons Unresponsive: Ensure the device is not in a locked mode. If the issue persists, try replacing batteries.

7. Specifications

7.1 AC / DC Voltage Measurement

Parameter Value
Range 600.0 V
Resolution 0.1 V
Accuracy (50 Hz to 400 Hz) ± (2% + 3)
Input impedance 3 MΩ (nominal value), <100 pF
Common Mode Rejection Ratio (1 kΩ unbalanced) > 60 dB, in DC, when 50 or 60 Hz
Overload protection 600 V rms or dc
Table detailing AC/DC voltage measurement specifications for the Fluke 1508.

Image: AC/DC Voltage Measurement Specifications.

7.2 Insulation Technical Specifications

Parameter Value
Measuring range 0.01 MΩ to 10 GΩ
Test voltage 50 V, 100 V, 250 V, 500 V, 1000 V
Test voltage accuracy + 20% - 0%
Short-circuit test current 1 mA, nominal value
Automatic Discharge When C = 1 μF or more, discharge time <0.5 s
Live circuit detection function During tests before initialization, if voltage > 30 V is detected, testing is banned.
Maximum capacitive load Up to 1 μF can be operated under load.
Table outlining Insulation Technical Specifications for the Fluke 1508.

Image: Insulation Technical Specifications.

7.3 General Specifications

Parameter Value
Applied to an arbitrary maximum voltage on the terminals 600 V ac rms or dc
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature Coefficient 0.05 × (specified accuracy) / °C, temperature <18 °C or> 28 °C (<64 °F or> 82 °F)
Relative humidity 0-95%, at 10 °C to 30 °C (50 °F to 86 °F)
0-75%, at 30 °C to 40 °C (86 °F to 104 °F)
0-40%, at 40 °C to 55 °C (104 °F to 131 °F)
Vibration protection Random, 2 g, 5-500 Hz, comply with MIL-PRF-28800F, Class 2 requirements
Impact protection 1 meter drop, in line with IEC 61010-1 2nd Edition (1 meter drop test, six faces, oak flooring) requirements
EMC At 3 V / M of the RF field, the accuracy of the given accuracy = (EN 61326-1:1997)
Security Comply with ANSI / ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2No. 1010.1 and IEC / EN 61010-1 2nd Edition for CAT IV 600 V equipment requirements
Certification CE, CSA, standard CSA / CAN C22.2 No. 1010.1; TUV, standard IEC/EN61010-1 2nd Edition
Battery 4 AA-size batteries (NEDA 15A or IEC LR6)
Battery life (Insulation test) At least 1000 insulation tests (1000 V, 1 MΩ, 5s on/25s off) at room temperature with new battery.
Battery life (Resistance measurements) At least 2500 earth resistance measurements (1 Ω, 5s on/25s off) at room temperature with new battery.
Size 5.0 cm high × 10.0 cm wide × 20.3 cm long (1.97 in height × 3.94 in × 8.00 in width long)
Weight 550 g (1.2 lb)
IP rating IP40
Altitude (Work) 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Altitude (Non-operating/storage) 12,000 m
Overload 110% of the range
Table presenting General Specifications for the Fluke 1508.

Image: General Specifications.

8. Warranty and Support

The Fluke 1508 Digital Insulation Multimeter is covered by the manufacturer's standard warranty. For specific warranty terms, duration, and conditions, please refer to the official Fluke documentation or contact Fluke customer support directly.

For technical assistance, troubleshooting, or service inquiries, please contact the authorized Fluke service center in your region.

9. User Tips

  • Chinese Interface: Please note that the buttons on this specific Fluke 1508 model are labeled in Chinese. It is recommended to familiarize yourself with the button functions using a translation guide or the provided manual diagrams to ensure correct operation.
  • Battery Life: To maximize battery life, always turn the device off when not in use. Remove batteries if the device will be stored for an extended period.
  • Safety First: Always double-check that the circuit is de-energized before performing insulation resistance tests to avoid safety interlocks and potential hazards.