1. Product Overview

The ZIBOO i600E AC Current Clamp is ergonomically designed with a non-slip handle, offering high precision, performance, anti-drop durability, safety, and stability. This current clamp accurately measures AC current and is designed for synchronous use with multimeters or clamp meters that feature an AC mV measurement function. It expands the AC current measurement range up to 600A, making it suitable for electrical maintenance, repair, and other specialized detections. It is an essential external current clamp measurement tool for factories and power distribution control system maintenance.

Key Features:

  • Compatible with most multimeters or mV AC measurement tools (e.g., 12E+, 15B+, 17B+, 18B+, 101, 106, 107, 110, etc.).
  • 600 mV AC range.
  • 1 mV/A AC output ensures easy current readings on your meter.
  • CAT III 600 V safety rating.
  • Compact design for maximum utility.
  • Enables accurate current readings without breaking the circuit.
ZIBOO I600E Current Clamp with Multimeter
The ZIBOO I600E Current Clamp connected to a multimeter.
ZIBOO I600E Current Clamp compatible with various multimeters
The ZIBOO I600E Current Clamp is compatible with a wide range of multimeters.

2. Setup

To use the ZIBOO I600E AC Current Clamp, connect its 4mm banana plugs to a compatible multimeter or clamp meter that supports AC mV measurement. Ensure the multimeter is set to the appropriate AC mV range for accurate readings.

ZIBOO I600E Clamp connected to a multimeter for mV AC function
Connect the clamp to your multimeter's mV AC input.

3. Operating Instructions

Once connected to a compatible multimeter, the ZIBOO I600E can measure AC current up to 600A. The output signal is 1mV/1A AC, which means your multimeter will display a voltage reading that directly corresponds to the current flowing through the clamp.

  1. Connect the Clamp: Plug the 4mm banana plugs of the current clamp into the appropriate input jacks of your multimeter.
  2. Select Measurement Mode: Set your multimeter to the AC mV (millivolt) measurement function.
  3. Clamp onto Conductor: Open the jaws of the current clamp and place it around a single conductor through which the AC current you wish to measure is flowing. Ensure the jaws are fully closed around the conductor.
  4. Read Measurement: The multimeter will display a voltage reading in mV. Convert this reading to Amperes using the 1mV/1A ratio (e.g., 100mV = 100A).
ZIBOO I600E Clamp measuring current on a cable
Properly clamp around a single conductor for accurate measurement.

Video: Product Overview and Unboxing

A short video demonstrating the unboxing and features of the ZIBOO I600E Current Clamp.

4. Safety Instructions & Precautions

WARNING: To prevent possible electrical shock, fire, or personal injury, please read all safety instructions carefully before using the product.

  • Always use the product strictly in accordance with the specified safety guidelines.
  • Measure within the specified current range. Do NOT measure currents exceeding 600A AC to avoid incorrect operation and potential damage to the device.
  • Do NOT touch the wires or areas near the clamp jaws during measurement to prevent electric shock.
  • DO NOT use the device in explosive environments or around flammable gases/vapors.
  • Inspect the clamp housing, test leads, and cables for any damage or exposed metal before each use. If any damage is found, stop using it immediately.
  • Comply with local and national safety codes. Use personal protective equipment (such as approved rubber gloves, face protection, and flame-resistant clothing) to prevent shock and arc blast injury where hazardous live conductors are exposed.

5. Specifications

ParameterValue
Product NameAC Current Clamp Adapter
ModelZIBOO i600E
AC Current Range1A ~ 600A
Max Input Current600A
Output SignalAC 1mV/1A
Accuracy (50~60Hz)±(2% + 0.5A)
Jaw Opening SizeΦ30mm / 1.26in
Dimensions (H x W x D)151H x 73W x 35D mm
Weight220g
Operating Temperature0℃ ~ 40℃
Storage Temperature-10℃ ~ 60℃
Humidity (Operating)≤75% (18℃~28℃)
Humidity (Storage)≤80%
Pollution Degree2
Operating Altitude0 ~ 2000 meters
Safety RatingCAT II 600V / CAT III 300V
Safety CertificationCE EN61010-1-2-032; EN61010-1-2-033
EMC StandardEN61326-1-2
Clamp Jaw Opening Size Diagram
Diagram illustrating the clamp jaw opening size.
Overall Dimensions Diagram
Diagram illustrating the overall dimensions of the current clamp.
AC Current Range and Accuracy Table
Detailed table of AC current ranges and their corresponding accuracy.

6. International Electrical Symbols

  • Caution: Indicates a hazardous operation or condition. Refer to the manual.
  • High Voltage: Indicates the risk of electric shock.
  • CE: Conforms to European Union directives.
  • Earth (Ground): Earth/Ground terminal.
  • Double Insulation: Protected throughout by double or reinforced insulation.
  • WEEE: Complies with the WEEE directive for recycling. Do not dispose of it in general household waste. Please dispose of it at an appropriate recycling facility.

7. Maintenance & Service

  • Repairs or servicing should only be performed by qualified and certified technical personnel.
  • DO NOT attempt to open the casing to repair the device yourself, as this may damage the instrument or cause an electric shock hazard.
  • If you cannot resolve a product fault, please contact our official after-sales service promptly.

8. Troubleshooting

If you encounter issues with your ZIBOO I600E Current Clamp, consider the following:

  • No Reading or Incorrect Reading:
    • Ensure the clamp is properly connected to the multimeter and the multimeter is set to the correct AC mV range.
    • Verify that the clamp jaws are fully closed around a single conductor.
    • Check if the current being measured is within the specified range (1A to 600A AC).
    • Inspect the test leads and clamp for any visible damage.
  • Inconsistent Measurements:
    • Some users have reported variability in measurements. If precision is critical for your application, consider performing multiple measurements and averaging the results, or re-calibrating your setup if possible. Ensure stable environmental conditions (temperature, humidity) as per specifications.

9. User Tips

  • For best accuracy, ensure the conductor is centered within the clamp jaws.
  • Always double-check your multimeter settings (AC mV range) before taking measurements.
  • Keep the clamp and leads clean and free from dust or debris to maintain optimal performance.

10. Additional Resources

For a complete and detailed user manual, please refer to the official PDF document:

View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.