1. Introduction and Overview
The PowMr POW-HVM11KP is an all-in-one hybrid solar inverter designed for efficient energy management. It integrates solar charging, AC/DC load supply, grid charging, bypass, and battery discharge functions. This inverter supports adjustable AC output voltage (220V/230V/240V) and provides a rated AC output of 11kW, boosting to 12kW when solar input exceeds 2000W. It features dual MPPTs for two independent PV arrays and is compatible with 48V lead-acid or lithium batteries, offering up to 150A charge current. For larger power requirements, up to 9 units can be connected in parallel, delivering a total output of up to 99kW, supporting both single and 3-phase configurations.
Product Overview Video
Video Description: This video provides an unboxing and overview of the PowMr Hybrid Solar Inverter, showcasing its components and key features. It highlights the inverter's all-in-one design, various charging and discharge functions, adjustable AC output, dual MPPTs, and parallel capability.
2. Package Contents
Upon opening the package, you should find the following items:
- 1 x PowMr Hybrid Solar Inverter (POW-HVM11KP)
- 1 x Parallel Communication Cable
- 1 x Current Sharing Cable
- 2 pairs of MC4 Connectors
- 2 x Battery Fuses
- 3 x Expansion Screws
- 1 x User Manual
3. Safety Information
Please read this manual carefully before installation and operation. Improper installation or use can result in electric shock, fire, or other serious hazards. Keep this manual for future reference.
- Ensure all connections are secure and correctly polarized.
- Do not attempt to open or repair the inverter yourself. Refer to qualified personnel.
- Install the inverter in a well-ventilated area, away from flammable materials and moisture.
- Always disconnect power sources (PV, battery, AC input) before performing any maintenance or wiring.
- Wear appropriate personal protective equipment (PPE) during installation and maintenance.

Image Description: This image displays the front of the PowMr Hybrid Solar Inverter, highlighting its built-in protection features including Overload protection, Charge short protection, AC reverse protection, Short-circuit protection, Bypass over current protection, Battery over voltage protection, Battery low voltage protection, and Parallel connection error protection.
4. Setup
4.1 Physical Installation
Mount the inverter securely using the provided expansion screws. Ensure adequate clearance for ventilation around the unit. The inverter is designed for wall mounting.
4.2 Wiring Connections
Refer to the wiring diagrams below for correct connection procedures. All wiring should be performed by a qualified electrician.

Image Description: A comprehensive wiring diagram illustrating connections for AC Input (utility grid or generator), Battery Input (48V lead-acid or lithium batteries), Dual-MPPT PV Input (solar panels), and AC Output (loads). The image also labels the inverter's ports: AC INPUT, MAIN OUTPUT, SECOND OUTPUT, RS232, Parallel Connection, DC INPUT, PV1, and PV2.
4.2.1 AC Input Connection
Connect the AC input from the utility grid or a generator to the designated AC INPUT terminals. Ensure the voltage and frequency match the inverter's specifications (220/230/240VAC, 50/60Hz).
4.2.2 Battery Connection
Connect the 48V battery bank (lead-acid or lithium) to the BATTERY INPUT terminals. Observe correct polarity. Use the provided battery fuses for protection.

Image Description: This image shows the PowMr Hybrid Solar Inverter connected to a 48V battery bank. It highlights the maximum PV input (15KW PV1+PV2) at 500V, dual-MPPT 150A, and maximum AC input of 150A. Various compatible 48V battery types like GEL, FLD, Li-ion, and USE are also indicated.
4.2.3 PV Input Connection
Connect your solar panel arrays to the PV1 and PV2 inputs. The inverter features dual MPPTs, allowing for two independent PV arrays. Ensure the PV input voltage and power are within the specified ranges (Max PV Input voltage: 500V, MPPT tracking voltage range: 90V ~ 500Vdc, Rated power: 7500W/7500W).
4.2.4 AC Output Connection
Connect your loads to the MAIN OUTPUT and SECOND OUTPUT terminals. The inverter provides stable AC power with a pure sine wave output.
4.3 Parallel Connection (Optional)
For increased power output or 3-phase operation, multiple inverters can be connected in parallel (up to 9 units). Use the provided Parallel Communication Cable and Current Sharing Cable for inter-inverter communication.

Image Description: This diagram illustrates how up to 9 PowMr Hybrid Solar Inverter units can operate in parallel for single or 3-phase configurations. It shows the connections for battery, utility grid, and loads, along with the communication connections between the parallel units.

Image Description: A specific diagram detailing a 3-Phase connection setup using three PowMr Hybrid Solar Inverter units (P1, P2, P3). It shows the battery, utility, and load connections for each phase, along with the necessary communication connections between the inverters.
5. Operating Instructions
5.1 LCD Interface
The inverter features an LCD interface that displays real-time information such as running mode, load status, input/output parameters, and fault codes. Use the navigation buttons (ESC, UP, DOWN, ENTER) to browse menus and adjust settings.
5.2 Output and Charging Priority Settings
The inverter supports configurable output and charging priority settings for smart energy management. These settings allow you to define how the inverter prioritizes power sources (solar, utility, battery) for charging and supplying loads. Refer to the detailed user manual for specific menu navigation and parameter adjustments.
5.3 Operating Modes
The inverter operates in different modes, including APL (Appliance) mode and UPS (Uninterruptible Power Supply) mode, which affect the transfer time when switching between power sources. For sensitive electronics, UPS mode offers a faster transfer time (10ms) compared to APL mode (20ms).
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust accumulation, which can hinder cooling. Use a soft, dry cloth.
- Connections Check: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
- Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal cleanliness as per battery manufacturer guidelines. For lithium batteries, follow their specific maintenance recommendations.
- Environment: Ensure the installation environment remains within the specified operating temperature and humidity ranges.
7. Troubleshooting
If the inverter is not functioning as expected, perform the following basic checks before contacting support:
- No Power: Check all circuit breakers and fuses (including battery fuses). Ensure AC input and battery connections are secure.
- No Output: Verify that the inverter is turned on and not in a fault state. Check load connections.
- Fault Codes: If the LCD displays a fault code, consult the comprehensive user manual for its meaning and recommended corrective actions.
- Overload: If an overload warning appears, reduce the connected load. The inverter has overload protection with specific time limits based on load percentage.
For persistent issues, contact PowMr customer support or a certified technician.
8. Specifications
8.1 General Specifications
| Feature | Specification |
|---|---|
| Constant Charging Voltage (Adjustable) | 56.4Vdc |
| Float Charging Voltage (Adjustable) | 54Vdc |
| PV Charging Mode | Dual MPPT |
| MAX. PV Input Power | 7500W/7500W (Total 15KW) |
| MPPT Tracking Range | 90~500Vdc |
| Operating Voltage | 360~430V |
| MAX. PV Input Voltage | 500Vdc |
| PV Max Input Current | 27A/27A |
| MAX. PV Charging Current | 150A |
| MAX. AC Charging Current | 150A |
| Display | LCD Interface (running mode/load/input/output, etc.) |
| RS232 Baud Rate | 2400 |
| Extend the Socket | Lithium Battery BMS Communication Card, WiFi Card |
| Communication Interface | Dry Contact |
| Parallel Machine Interface | Parallel Machine (network) function |
| Operating Temperature | -10°C~50°C |
| Humidity | 20%~95% (Non-condensing) |
| Storage Temperature | -15°C~60°C |
| Altitude | Not Over 1000m, Derating over 1000m, Max 4000m (Refer to IEC62040) |
| Noise | ≤50db |
| Standards and Certification | EN-IEC 60335-1, EN IEC 60335-2-29, IEC 62109-1, CE, FCC, RoHS |
| Dimension (D*W*H) | 560x490x155mm |
| Net Weight | 19.75kg |

Image Description: A detailed table outlining the general specifications of the PowMr Hybrid Solar Inverter, including charging voltages, PV input parameters, charging currents, display features, communication interfaces, environmental conditions, noise levels, certifications, dimensions, and net weight.
8.2 Model Specific Specifications (POW-HVM11KP)
| Category | Feature | Specification |
|---|---|---|
| AC Input | Input Sources | L+N+PE |
| Rated Input Voltage | 220/230/240VAC | |
| Voltage Range | 90-280VAC±3V (APL Mode); 170-280VAC±3V (UPS Mode) | |
| Frequency | 50Hz/60Hz (Auto Adaptive) | |
| Battery Voltage | 48Vdc | |
| Inverter Output | Rated Power (Battery Inverter) | 11000W |
| Rated Power (Photovoltaic Inverter) | 12000W | |
| Output Voltage | 220/230/240VAC±5% | |
| Output Frequency | 50Hz/60Hz±0.1% | |
| Waveform | Pure Sine Wave | |
| Transfer Time (Adjustable) | Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms | |
| Peak Power | 22000VA | |
| Overload Capacity | Battery mode: 11s@105%~150% Load; 2s@150%~200% Load; 400ms@>200% Load | |
| Grid-Connected Operation | Output Voltage | 220/230/240VAC±5% |
| Feed Into the Grid Voltage Range | 170-265VAC | |
| Feed Into the Grid Frequency Range | 49-51±1Hz/59-61±1Hz | |
| Nominal Output Current | 47.8A | |
| Power Factor Range | >0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% |

Image Description: A detailed table presenting the model-specific specifications for the POW-HVM11KP inverter, covering AC input parameters, inverter output characteristics (rated power, voltage, frequency, waveform, transfer time, peak power), overload capacity, and grid-connected operation details.
9. Warranty and Support
For warranty information, technical support, or service requests, please refer to the official PowMr website or contact your authorized dealer. Keep your purchase receipt and product serial number handy when contacting support.
10. User Tips
- Monitor Performance: Regularly check the LCD display for system status and performance metrics to ensure optimal operation.
- Battery Compatibility: When connecting batteries, ensure they are 48V and compatible with the inverter's charging profiles (lead-acid or lithium). Incorrect battery types or voltages can damage the system.
- Parallel Expansion: If expanding with parallel units, ensure all inverters are of the same model and firmware version for seamless integration and stable operation.