1. Introduction
This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of your Hikmicro Haikang Micro Shadow Infrared Imaging Device. Please read this manual thoroughly before using the device and keep it for future reference.
The Hikmicro Haikang Micro Shadow series (including models H10, H11, H21pro, E09, and E09 Pro) are advanced infrared imaging devices designed for smart floor heating pipe leakage detection and general thermal inspection. They offer rapid, visible temperature measurement across a wide field of view.
2. Safety Information
Always observe the following safety precautions to prevent injury and damage to the device:
- Do not point the laser directly at eyes or reflective surfaces. The device contains a Class 2 laser.
- Do not expose the device to extreme temperatures, humidity, or corrosive environments.
- Avoid dropping or subjecting the device to strong impacts.
- Use only approved accessories and power adapters.
- Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
- Keep the device away from water and other liquids.
3. Device Components
Familiarize yourself with the main components of your infrared imaging device:

- Infrared Lens: Captures thermal radiation.
- Visible Light Camera (if applicable): Captures standard visual images.
- Display Screen: Shows thermal and visual images, menu, and data.
- Trigger Button: Activates measurement or captures images/videos.
- Navigation Buttons: For menu navigation and settings adjustment.
- Laser Pointer: (Class 2 Laser) Used for target indication.
- USB Port: For charging and data transfer.
- Battery Compartment: Houses the rechargeable battery.
4. Setup
4.1 Unpacking and Initial Inspection
Carefully unpack the device and all accessories. Inspect for any signs of damage. If any components are missing or damaged, contact your vendor immediately.
4.2 Charging the Battery
- Locate the USB charging port on the device.
- Connect the provided USB cable to the device and a suitable USB power adapter.
- Plug the power adapter into a wall outlet.
- The charging indicator will illuminate. Allow the device to charge fully before first use.
4.3 Powering On/Off
- To Power On: Press and hold the power button until the screen illuminates.
- To Power Off: Press and hold the power button until the shutdown prompt appears, then confirm.
5. Operating Instructions
5.1 Basic Operation
The Hikmicro Haikang Micro Shadow device provides rapid and comprehensive thermal imaging. It can measure temperature across 36864 points simultaneously, offering a significant advantage over single-point thermometers.


5.2 Thermal Imaging Modes
Your device may feature various imaging modes, such as:
- Thermal Mode: Displays only the infrared image.
- Visual Mode: Displays only the visible light image (if equipped).
- Fusion Mode: Overlays thermal and visual images for enhanced detail.
- Picture-in-Picture Mode: Displays a small thermal image within a larger visual image.
Navigate through the menu using the navigation buttons to select your desired imaging mode.
5.3 Taking Measurements and Capturing Images/Videos
- Aim the device at the target area.
- Adjust focus if necessary (manual or auto-focus, depending on model).
- Press the trigger button to capture a thermal image or start/stop video recording.
- Captured data is typically saved to internal memory or an SD card (if supported).
5.4 Laser Pointer Usage
The integrated laser pointer can be activated via a dedicated button or menu option to precisely indicate the measurement target. Exercise caution and avoid direct eye exposure.
6. Maintenance
6.1 Cleaning the Device
- Lens: Use a soft, lint-free cloth and a specialized lens cleaning solution. Do not use abrasive materials.
- Body: Wipe the device body with a soft, damp cloth. Avoid harsh chemicals.
6.2 Battery Care
- Charge the battery regularly, even if the device is not in use, to maintain battery health.
- Store the device in a cool, dry place when not in use for extended periods.
6.3 Firmware Updates
Periodically check the manufacturer's website for firmware updates to ensure optimal performance and access to new features. Follow the provided instructions carefully for any update procedures.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Battery is depleted or not properly inserted. | Charge the battery. Ensure the battery is correctly inserted. |
| Image is blurry or out of focus. | Incorrect focus setting or dirty lens. | Adjust the focus. Clean the infrared lens carefully. |
| Temperature readings seem inaccurate. | Incorrect emissivity setting or environmental factors. | Verify and adjust the emissivity setting for the target material. Consider environmental conditions. |
| Device freezes or becomes unresponsive. | Software glitch. | Perform a soft reset (refer to specific model instructions for button combination, usually holding power button for 10+ seconds). |
8. Specifications
Please note that specifications may vary slightly between specific models (H10, H11, H21pro, E09, E09 Pro).
| Feature | Detail |
|---|---|
| Model Series | Hikmicro Haikang Micro Shadow (H10/H11/H21pro, E09/E09 Pro) |
| Application | Infrared Imaging, Floor Heating Pipe Leakage Detection |
| Field of View (FOV) | Typically 50° x 50° (for comprehensive coverage) |
| Temperature Measurement Points | Up to 36864 points (multi-point measurement) |
| Laser | Class 2 Laser |
| Fixed Type (from product properties) | Hook & Loop Fastener |
| Use (from product properties) | Window |
| Origin (from product properties) | Mainland China |
| Package Weight | 0.8 kg |
| Package Dimensions (L x W x H) | 12 cm x 12 cm x 22 cm |
9. User Tips
- For accurate leakage detection, ensure the area is free from drafts or direct sunlight, which can affect thermal readings.
- Practice using the different imaging modes to find the best visualization for your specific inspection task.
- Regularly transfer saved images and videos to a computer to free up device memory.
- When inspecting reflective surfaces, try to adjust your angle or use matte tape to reduce reflections that can interfere with thermal readings.
10. Frequently Asked Questions (FAQ)
- Q: How do I know if the battery is fully charged?
- A: The charging indicator light will change color or turn off when the battery is fully charged. Refer to your specific model's display for on-screen battery status.
- Q: Can I use the device in wet conditions?
- A: The device is not waterproof unless explicitly stated in the specifications. Avoid exposure to water or high humidity to prevent damage.
- Q: What is emissivity and why is it important?
- A: Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. Setting the correct emissivity in the device's settings is crucial for accurate temperature measurements. Consult an emissivity table for common materials.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original point of purchase or refer to the official Hikmicro website for detailed support resources.
Ensure you have your device's model number and serial number ready when contacting support.