1. Introduction
This manual provides essential information for the safe and efficient operation of your Daxtromn GGH-3.5KW 3500W Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference. This inverter is designed to convert DC power from solar panels into AC power for your home or business, with integrated MPPT solar charging and hybrid functionality.

Figure 1: Front view of the Daxtromn GGH-3.5KW Hybrid Solar Inverter, highlighting its 80A Max 24V DC Charger, 3.5KW Rated Power, 500V Max DC PV Input, and certifications (CE, FC, RoHS).
2. Safety Information
- WARNING: DO NOT CONNECT THE OUTPUT TO THE GRID. Connecting the inverter's output directly to the utility grid without proper synchronization and safety measures will damage your inverter and potentially create hazardous conditions.
- WARNING: The inverter cannot be paralleled. This model is not designed for parallel operation with other inverters. Attempting to parallel multiple units may result in damage and void the warranty.
- Ensure all wiring is performed by qualified personnel and complies with local electrical codes.
- Do not operate the inverter if it is damaged or appears to be malfunctioning.
- Keep children away from the inverter and its connections.
- Ensure adequate ventilation around the inverter to prevent overheating.
3. Product Overview
3.1 Key Features
- Pure Sine Wave Solar Inverter
- Max 80A MPPT Solar Charger
- Max 500VDC PV Input
- High PV input voltage range (120 ~ 450VDC)
- Output power factor 1.0
- Real Hybrid Solar inverter for 24V system
- Efficient operation with or without battery
- Bundled Monitoring & Setting Software
- Supports 50Hz or 60Hz (adjustable program)
- Able to use AC grid or power generator as input
- Built-in anti-dusk kit for harsh environments
- Compatible with lead-acid, LiFePO4, and other lithium batteries, or can operate without a battery.
3.2 Structure and Interface Description

Figure 2: Structure size and interface description of the inverter.

Figure 3: Detailed view of the inverter's interface components.
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input
- AC output
- Battery input
- PV input
- Circuit breaker
- Dry contact
- Parallel communication port (Not Supported on this model)
- BMS communication port
- RS232 communication port
4. Setup
4.1 Installation Location
- Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
- Ensure the mounting surface is sturdy enough to support the inverter's weight (approximately 11 kg).
- Maintain adequate clearance around the inverter for proper airflow (refer to Figure 2 for dimensions: 302mm width, 490mm height, 110mm depth).
- The inverter is equipped with an anti-dusk kit, making it suitable for harsh environments, but protection from direct moisture and extreme temperatures is still recommended.
4.2 Wiring Diagram
The following diagram illustrates the typical wiring connections for the Daxtromn GGH-3.5KW Hybrid Solar Inverter. Ensure all connections are secure and correctly polarized.

Figure 4: Inverter Wiring Diagram.
- PV Input: Connect your solar panel array to the PV input terminals (10). Ensure the total PV input voltage does not exceed 500VDC and the maximum PV input power is within 5000W.
- Battery Input: Connect your 24V battery bank to the Battery input terminals (9). Observe correct polarity.
- AC Input: Connect the utility grid or a power generator to the AC input terminals (7).
- AC Output: Connect your AC loads to the AC output terminals (8).
- Circuit Breaker: Ensure the circuit breaker (11) is correctly installed and rated for your system.
- Communication Ports: Utilize the BMS communication port (14) and RS232 communication port (15) for monitoring and advanced settings. The parallel communication port (13) is not supported.
5. Operating Instructions
5.1 Initial Startup
- After all connections are made and verified, turn on the battery breaker (if applicable).
- Turn on the PV array breaker (if applicable).
- Turn on the AC input breaker (if applicable).
- Press the Power On/Off switch (6) on the inverter.
- Observe the LCD display (1) and status indicators (2, 3, 4) for normal operation.
5.2 LCD Display and Function Buttons
The LCD display provides real-time information about the inverter's status, input/output voltages, battery charge, and more. Use the function buttons (5) to navigate through menus and adjust settings. Refer to the bundled monitoring and setting software for detailed configuration options.
5.3 Battery Management System (BMS) Communication
The inverter supports communication with batteries equipped with a BMS. When a BMS-enabled battery is connected via the BMS communication port (14), the inverter and battery will communicate to automatically adjust charging voltage, cut-off voltage, and other parameters. This dynamic adjustment optimizes battery life and enhances safety. If your battery does not have a BMS, the inverter will operate with default or manually set parameters.
6. Maintenance
- Regularly inspect the inverter for any visible damage, loose connections, or signs of overheating.
- Keep the inverter's ventilation openings clear of dust and debris to ensure proper cooling. Use a soft brush or compressed air for cleaning.
- Check battery terminals for corrosion and clean if necessary.
- Ensure all wiring connections remain tight and secure.
- Periodically review system performance via the monitoring software to identify any anomalies.
7. Troubleshooting
7.1 Common Issues and Solutions
- Inverter not turning on: Check battery connections, battery voltage (must be 24V), and the power on/off switch. Ensure the circuit breaker is not tripped.
- No AC output: Verify AC output connections, check for overload conditions, and ensure the inverter is receiving sufficient input power from PV or AC grid.
- Low PV input/charging: Check solar panel connections, ensure panels are clean and not shaded, and verify PV input voltage is within the 120-450VDC MPPT range.
- Fault indicator lit: Refer to the inverter's LCD display for specific error codes and consult the detailed troubleshooting guide in the monitoring software manual.
7.2 User Tips
- For optimal battery life and safety, use a 24V external battery with a compatible BMS. The inverter can communicate with most BMS protocols; check for compatibility if unsure.
- Regularly monitor the system's performance using the provided software to catch potential issues early.
- Ensure your solar array's open-circuit voltage (Voc) does not exceed 500VDC to prevent damage to the inverter.
8. Specifications
The following table details the specifications for the 3500VA/3500W model of the Daxtromn GGH-3.5KW Hybrid Solar Inverter.

Figure 5: Detailed Product Specifications.
| Parameter | Specification (3500VA/3500W Model) |
|---|---|
| Rated Power | 3500VA/3500W |
| Input Voltage | 230VAC |
| Selectable Voltage Range | 170 ~ 280VAC (for Personal Computers), 90 ~ 280VAC (for Home Appliances) |
| Frequency Range | 50Hz/60Hz (Auto sensing) |
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
| Surge Power | 7000VA |
| Efficiency (Peak) PV to INV | 97% |
| Efficiency (Peak) Battery to INV | 94% |
| Transfer Time | 10ms (for Personal Computers), 20ms (for Home Appliances) |
| Battery Voltage | 24VDC |
| Floating Charge Voltage | 27VDC |
| Overcharge Protection | 33VDC |
| Maximum Charge Current | 80A |
| Solar Charger | 80A MPPT |
| Maximum PV Array Power | 5000W |
| MPPT Range @ Operating Voltage | 120 ~ 450VDC |
| Maximum PV Array Open Circuit Voltage | 500VDC |
| Maximum Charging Current | 80A |
| Maximum Efficiency | 98% |
| Dimension D*W*H (mm) | 100*300*440 |
| Net Weight (kgs) | 11 |
| Communication Interface | USB/RS232/GPRS/WIFI |
| Operating Environment Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature | 0°C ~ 55°C |
| Storage Temperature | -15°C ~ 60°C |
9. Warranty and Support
9.1 Warranty Information
The Daxtromn GGH-3.5KW Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, unauthorized modifications, or external factors such as lightning strikes or power surges. Please retain your proof of purchase for warranty claims.
9.2 Technical Support
For technical assistance, troubleshooting, or warranty inquiries, please contact Daxtromn customer support through your point of purchase or the official Daxtromn website. Have your product model and serial number ready when contacting support.