1. Introduction
The WT8822 Portable Hydrogen Sulfide (H2S) Gas Detector is a professional instrument designed for accurate and sensitive monitoring of H2S gas concentrations. It is suitable for various applications including biological medicine, fire detection, and industrial safety where H2S gas presence needs to be monitored. This manual provides essential information for the safe and effective use of your device.
2. Safety Information
- Read all instructions thoroughly before operating the device.
- Do not attempt to disassemble, modify, or repair the device yourself. Refer to qualified personnel for service.
- Use only the specified battery type (3 x 1.5V AAA Alkaline batteries).
- Warning: Prohibit charging or disassembling batteries in an explosive environment.
- Avoid exposing the device to extreme temperatures, high humidity, or corrosive environments.
- Keep the sensor area clean and free from obstructions to ensure accurate readings.
3. Product Overview
3.1 Package Contents
- 1 x WT8822 H2S Detector
- 1 x Instruction Manual
- 1 x Black Protective Box

3.2 Device Components, Display, and Controls


The device features an LCD screen for displaying readings and status, along with several control buttons:
- Display: Shows H2S concentration (e.g., PPM, mg/m³), temperature (°C), battery level, MAX/MIN indicators, HOLD status, and alarm status.
- LIGHT Button: Controls the display backlight and serves as the power ON/OFF button.
- HOLD Button: Freezes the current measurement on the display.
- MAX/MIN Button: Cycles through the maximum and minimum H2S concentration values recorded.
- UNIT Button: Changes the measurement unit for H2S concentration.

4. Specifications
| Feature | Specification |
|---|---|
| Product Name | Hydrogen Sulfide Detector |
| Model | WT8822 |
| Brand | Aramox |
| Measurement Range | 0-100 PPM; 0-0.01 VOL%; 0-152 Mg/m³; 0-0.23 LEL% |
| Maximum Overload | 500 PPM |
| Sensor Type | Electromagnetic H2S sensor |
| Working Voltage | 4.5V |
| Battery Type | 3 x 1.5V AAA Alkaline Battery (Not Included) |
| Ambient Humidity | 15-90% RH |
| Material | ABS |
| Certification | CE |
| Explosion-proof Certificate No. | Ex ib IIB T3 Gb |
| DIY Supplies Category | Electrical |
| Origin | Mainland China |
| Package Dimensions (L x W x H) | 28 cm x 20 cm x 7 cm |
| Package Weight | 0.667 kg |
5. Setup
5.1 Battery Installation
- Locate the battery compartment cover on the back of the device (refer to Figure 4).
- Slide or unclip the cover to open the compartment.
- Insert three (3) 1.5V AAA Alkaline batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.
5.2 Initial Power On
After installing the batteries, press and hold the LIGHT button for a few seconds to power on the device. The display will illuminate and show initial readings.
6. Operating Instructions
6.1 Power On/Off
- To Power On: Press and hold the LIGHT button.
- To Power Off: Press and hold the LIGHT button again until the display turns off.
6.2 H2S Measurement
Upon powering on, the device will automatically begin measuring H2S concentration in the ambient air. The current H2S reading, along with the temperature, will be displayed on the LCD screen.
6.3 Alarm Function
The WT8822 is equipped with a high-sensitivity alarm system. When the concentration of H2S in the air exceeds a preset standard, the device will immediately issue both a sound and light alarm. The current concentration value will be displayed prominently.
6.4 Data Hold (HOLD)
To freeze the current H2S concentration reading on the display, press the HOLD button. Press the HOLD button again to release the held value and resume real-time measurement.
6.5 Maximum/Minimum Readings (MAX/MIN)
Press the MAX/MIN button to view the highest (MAX) and lowest (MIN) H2S concentration values recorded since the device was powered on or reset. Pressing the button repeatedly will cycle between MAX, MIN, and current readings.
6.6 Unit Conversion (UNIT)
To switch between different measurement units for H2S concentration (e.g., PPM, mg/m³), press the UNIT button.
6.7 Backlight Control (LIGHT)
A short press of the LIGHT button will toggle the display backlight on or off, improving visibility in low-light conditions.
6.8 Timing Switch Machine
The device supports a timing switch machine function to conserve battery life. This feature allows you to set a specific time for the device to automatically power on or off, reducing the need for manual operation. Refer to the on-screen menu or further documentation for detailed instructions on setting this feature.
7. Maintenance
7.1 Cleaning
Wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure the sensor area remains clean and free of dust or debris.
7.2 Battery Replacement
When the low battery indicator appears on the display, replace all three 1.5V AAA Alkaline batteries promptly. Follow the battery installation steps in Section 5.1.
7.3 Storage
When not in use for extended periods, store the WT8822 detector in its original black protective box in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Troubleshooting
- Device not powering on: Check if batteries are installed correctly and have sufficient charge. Replace with new batteries if necessary.
- Inaccurate or erratic readings: Ensure the sensor area is clean and unobstructed. Verify that the device is operating within the specified ambient humidity range (15-90% RH).
- Alarm not sounding/flashing: Check for any physical obstructions around the alarm speaker or LED indicators. Ensure the device is not in a silent mode (if applicable, though not explicitly detailed for this model).
- Display issues (e.g., blank, dim): Check battery level. If the issue persists, contact support.
9. User Tips
- For optimal performance, allow the device a few moments to stabilize after powering on before taking critical measurements.
- Always store the detector in its protective case when transporting to prevent damage to the sensor or display.
- Be aware of the specific H2S exposure limits relevant to your application and ensure the device's alarm thresholds are appropriate for your safety protocols.
10. Warranty and Support
For information regarding warranty coverage, technical support, or service, please refer to the documentation provided by your retailer or visit the manufacturer's official website. Keep your purchase receipt as proof of purchase.