Introduction
The Haozee Tuya Zigbee Solar Light Sensor is a smart, wireless device designed for indoor and outdoor brightness detection. It integrates seamlessly with Zigbee and Tuya smart home platforms, including support for Home Assistant and Zigbee2mqtt. Featuring solar power for sustainable operation and an IP65 waterproof rating, this sensor provides accurate light level data to enable intelligent automation in various environments.

Overview of the Solar Light Sensor highlighting its features like solar charging, 83000LUX range, IP65 waterproofing, and Texas Instruments IC.
Setup
1. Physical Installation
The sensor offers flexible installation options for both indoor and outdoor use:
- Placement / Flat Pasting: Place the sensor on a flat surface or use adhesive for flat pasting.
- Side Stickers / Ceiling Stickers: Utilize adhesive stickers for mounting on vertical surfaces or ceilings.
- Outdoor Rain / Wall Mounted: For outdoor use, the IP65 rating ensures durability. Mount it on a wall using the provided screws.
- Attach / Expand Screws: Secure the sensor using screws for a more permanent installation.

Visual guide for different installation methods including placement, stickers, and screw mounting.
2. Device Pairing (Zigbee)
To connect the sensor to your smart home system (Tuya, Home Assistant, Zigbee2mqtt), follow these steps:
- Ensure your Zigbee gateway/hub is powered on and in pairing mode.
- Remove the back cover of the Solar Light Sensor.
- Press and hold the reset button for 5 seconds. The orange pilot lamp will indicate pairing mode.
- The sensor will attempt to connect to the nearest Zigbee gateway.
- Once connected, the pilot lamp will stop blinking or change color (refer to your gateway's instructions for confirmation).
- Add the device within your Tuya Smart app, Home Assistant, or Zigbee2mqtt interface.
3. Reset / Reconfiguration Method
If you need to reset the sensor to factory settings or re-enter pairing mode:
- Method 1 (Button): Remove the back cover and press the reset button for 5 seconds. This will restore factory settings and enter reconfiguration mode.
- Method 2 (Tilt - Optional): Tilt the sensor 45 degrees for 10 seconds and then restore it to its original position. This will also enter reconfiguration mode.
Operating Instructions
1. Brightness Detection
The sensor continuously monitors ambient light levels within a detection range of 0 to 83000 LUX. Data is reported every 5 seconds, with an additional fixed-time report every 180 seconds. The sensitivity is 5 LUX when the ambient light is ≤ 100 LUX, ensuring accurate readings even in low-light conditions.
2. Solar Power and Battery
The sensor is equipped with a solar panel for power. For outdoor use, solar energy continuously replenishes the nickel-metal hydride battery, eliminating the need for manual battery replacement. For indoor use, charging the sensor in sunlight for one day can provide power for nearly a year.
3. Smart Automation Linkage
Leverage the brightness data to create intelligent automation rules within your smart home platform. Examples include:
- Automated Curtain Control: If the luminance exceeds 800 LUX, automatically close smart curtains.

Example automation: If luminance is greater than 800 lux, close the curtain motor.
- Automated Lighting Control: If the luminance exceeds 800 LUX, automatically turn off service hall lights.

Example automation: If luminance is greater than 800 lux, turn off the service hall light.
Maintenance
- Solar Panel Cleaning: Periodically wipe the solar panel with a soft, damp cloth to ensure optimal charging efficiency. Avoid abrasive cleaners.
- Environmental Exposure: While the sensor is IP65 waterproof, extreme weather conditions (e.g., heavy snow accumulation on the solar panel) may temporarily affect performance. Ensure the solar panel is clear of obstructions.
- Battery Life: The internal nickel-metal hydride battery is designed for long-term use with solar replenishment. For indoor use, ensure it receives adequate sunlight exposure for charging as described in the 'Operating Instructions'.
Troubleshooting
- Sensor Not Reporting Data:
- Check if the sensor is properly paired with your Zigbee gateway. If not, perform the reset/reconfiguration method.
- Ensure the sensor has sufficient power. For outdoor use, verify the solar panel is clean and exposed to sunlight. For indoor use, ensure it has been charged.
- Verify the Zigbee network is stable and the sensor is within range of the gateway.
- Inaccurate Brightness Readings:
- Ensure the sensor's light detection area is not obstructed or dirty.
- Confirm the sensor is placed in an area representative of the light levels you wish to measure.
- Automation Rules Not Triggering:
- Double-check your automation rules in the smart home app for correct conditions and actions.
- Verify the sensor is reporting data correctly to the app.
Specifications
| Project | Subitem | Description |
|---|---|---|
| Brand | brand | Neutral / OEM / ODM |
| Model | model | Solar Light Sensor |
| Product size (mm) | Product size (mm) | Bottom length * bottom width * height = 70mm * 70mm * 29mm |
| Top length * top width * height = 63mm * 63mm * 29mm | ||
| Packing | packing measurement (mm) | Length * width * height = 70mm * 70mm * 42mm |
| Sensor/gross weight = 80g (with battery) 60g (without battery) | ||
| Sense IC | sense IC | OPT3004DNPR |
| Basic specifications | Main control chip | TLSR8258 |
| Material/color of the shell body | ABS + PC / white | |
| pilot lamp | LED (orange): 1 | |
| power dissipation | Rated power consumption: 0.0010W maximum power consumption: 0.0027W | |
| power supply mode | Outdoor use: solar energy is used to replenish nickel metal hydride battery cycle, so that it does not need to be replaced all the time. Indoor use: solar light charging for 1 day, can be used for nearly a year when placed indoors. | |
| Use ambient temperature | -20°~+70° | |
| levels of protection | IP65 | |
| detection zone | Brightness: 0LUX~83000LUX | |
| The detection status | sensitivity | 5lux sensitivity when ≤ 100LUX |
| Exploration cycle | 5 seconds per report algorithm plus 180 seconds per fixed time, short press reset key can actively report | |
| Device support | Support platforms | Graffiti intelligence |
| protocol | Zigbee | |
| Reset / upgrade method | Remove the back cover and press the reset button for 5 seconds to restore the factory and enter the reconfiguration mode (optional) The sensor is tilted 45 degrees for 10 seconds and then restored to factory and enters the reconfiguration mode (optional) | |
| International certification | RoHS | --- |
| CE | --- | |
| Enchase | packing quantity | Fifty |
| packing measurement | Length * width * height = 380mm x 380mm x 100mm | |
| Packing weight | 4.67kg |
User Tips
- Optimal Placement: For accurate readings, place the sensor where it receives representative light for the area you want to monitor. Avoid direct spotlights or shadows that don't reflect the overall room brightness.
- Gateway Proximity: Ensure the sensor is within effective range of your Zigbee gateway for reliable communication. Walls and other obstructions can reduce signal strength.
- Solar Charging Best Practices: Even for indoor use, occasionally place the sensor near a window or in direct sunlight for a few hours to ensure the internal battery remains fully charged, especially if it's in a consistently dim location.
- Automation Testing: After setting up automation rules, test them thoroughly to ensure they function as expected under different light conditions.
Warranty and Support
For warranty information, technical support, or further assistance, please refer to the official Haozee website or contact your retailer. Keep your purchase receipt as proof of purchase.