1. Introduction
The HeltecBMS Lithium Battery Capacity Tester is a versatile device designed for precise testing of various battery types, including lithium-ion, LiFePO4, NMC, and lead-acid batteries. It integrates high-precision capacity series discharge detection and high-precision charging functions. This instrument is suitable for electric vehicle dealers and battery manufacturers to assess battery performance, offering features such as capacity testing, battery charge and discharge cycles, and detailed data collection via host computer software. It can accurately collect battery voltage signals in real time, store them, and process data. It features high precision, strong timeliness, simple operation, and practical reliability.
2. Product Features
- Automatic Data Collection: Automatically collects and analyzes battery voltage, continuously outputting a constant current or power.
- Software Control: Connects to a host computer for convenient and efficient operation and control.
- Adjustable Current: Current is adjustable, with peak discharge current reaching up to 50A (depending on model).
- Reverse Polarity Protection: Features reverse polarity protection for both positive and negative terminals, ensuring battery safety.
- Real-time Display: Simplified operation interface displays voltage, capacity, current, and other parameters in real-time, supporting both Chinese and English languages.
- Powerful PC Software: Provides advanced functions such as data management, exporting, analysis, and report statistics.
- Multiple Operating Modes: Ten working modes are available to meet the requirements of different batteries, including Charging, Discharging, Voltage Balancing, and Cycle modes.
- Intelligent Cooling: Equipped with intelligent cooling fans for faster heat dissipation and better performance.
- High Compatibility: Supports various battery types including LFP, NCM, NiMH, LCO, soft pack batteries, and square cells.


3. Setup
Before operating the machine, ensure all connections are secure and correct. Improper connection may lead to battery explosion or fire.
3.1 Product List (HT-BCT10A30V Example)

3.2 Product List (HT-BCT50A4C Example)

3.3 Product List (HT-DC50ABP Example)

3.4 Connection Warning

Warning: Please use this machine under the guidance of professionals. Incorrect settings may cause battery explosion and fire!
4. Operation
This section details the operation of the battery capacity tester. Please read the instructions carefully before operating the machine.
4.1 General Operation Steps
- Start-up and Battery Connection: Start the machine and then clip the battery to the appropriate terminals, ensuring correct polarity.
- Access Settings: Press the setting knob to enter the setting page.
- Adjust Parameters: Rotate the setting knob left and right to adjust parameters such as charge cutoff voltage, charge current, discharge cutoff voltage, discharge current, rest time, and cycle options. Press the knob to confirm each setting.
- Save Settings: After configuring all parameters, select "Save/Exit" to save the settings and return to the main display.
- Mode Selection: On the main display, rotate the setting knob to switch between different working modes (e.g., Voltage Balance Mode, Charge Mode, Discharge Mode, Cycle Mode).
- Start Operation: Press the START/STOP button to begin the selected operation.
- View Results: After the test is complete, the result page will automatically pop up, displaying test results and curves.
4.2 Detailed Parameter Setting (HT-BCT10A30V Example)

The video below demonstrates the parameter setup and operation:
4.3 Mode Selection
The device offers various working modes to suit different testing requirements. Rotate the setting knob to select the desired mode.
| Pattern Coding | Function |
|---|---|
| 0 | Historical circular data query mode |
| 1 | Capacity test |
| 2 | Standard (Charging only) |
| 3 | Start with discharge and end of charge, 1-50 cycles |
| 4 | Start charge and end charging with 1-50 cycles |
| 5 | Start with discharge and end with 1-50 cycles |
| 6 | Start charge and end discharging, cycle times |
| 7 | Networking mode |
| 8 | Pulse Repair Mode |
| 9 | Charge → Pulse Repair → Discharge |


4.4 Data Visualization and Analysis
The device provides intuitive data visualization and analysis capabilities, especially when connected to the host computer software.

The host computer software allows for:
- Displaying battery parameters and test status.
- Viewing voltage, current, and capacity curves over time.
- Customizing the color of the test status pane.
- Generating data reports.
5. Specifications
5.1 General Technical Parameters (HT-BCT10A30V Example)
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Machine weight | 10KG | Maximum number of charge and discharge cycles | 50 times |
| Machine size | Length:66cm Width:28cm Height:16cm | Current and voltage adjustment mode | knob adjustment |
| Warranty period | 1 year | Single discharge maximum power | 138W |
| Input voltage | 220V | Single charge and discharge maximum timing | 90 hours |
| Charging voltage range | 7-23V adjustable, voltage 0.1V adjustable | Single standby power consumption | 20W |
| Charging current range | 0.5-6A adjustable, current 0.1V adjustable | Screen display language | Chinese/English |
| Charging current accuracy | ±0.03A/±0.3% | Number of charging and discharging circuits | circuit 6 |
| Discharge voltage range | 2-20V adjustable, voltage 0.1V adjustable | Discharge current accuracy | ±0.03A/±0.3% |
| Machine temperature adjustment | real-time monitoring of the temperature in the body during charging and discharging and adjusting the times of fan revolutions | ||

5.2 HT-DC50ABP Product Parameters
| Category | Detail | Category | Detail |
|---|---|---|---|
| Product Name | Lithium Battery Capacity Tester (Discharge) | Product Model | HT-DC50ABP |
| Scope of Application | Batteries within 5 to 120V | AC Input | AC110-240V 50/60HZ |
| Discharge Parameters | 5-120V adj (step 0.1V) 1-50A adj (step 0.1A) 5-10V max 20A; 10-120V max 50A The maximum discharge power is 6000W | Working Mode | Constant voltage discharge / Timed discharge / Constant capacity discharge |
| Calibration Equipment | Voltage standard: Fluke 8845A Current standard: GW Instek PCS-10001 | Error Range | Voltage ±0.1%, current ±0.2% |

5.3 Apparent Dimensions




6. Maintenance
6.1 General Tips
- The effectiveness of capacity testing is related to both time and speed. For improved accuracy, it is recommended to set a smaller discharge current value.
- No capacity tester can test a damaged battery. Damaged batteries include those with increased internal resistance, terminal voltage lower than discharge cutoff, or internal short circuit/open circuit.
- Always read the instruction manual carefully.
6.2 Environmental Considerations
- Keep the ambient temperature and humidity within the recommended range when the equipment is in use.
- Ensure proper ventilation: The air inlet at the back and outlets on the left and right sides of the equipment must not be blocked. Maintain a ventilation space of more than 5CM. The air inlet at the bottom should be unobstructed.
- Store the device properly and avoid violent actions or collisions during use and transportation.
- Keep away from flammable and explosive materials.



7. Troubleshooting
| Encountered Problem | Reason | Solution |
|---|---|---|
| After the power is turned on, the display screen does not light up | 1. Power plug not properly connected | 1. Re-insert the power plug |
| 2. Fuse of the power outlet is blown | 2. Replace with a 5A fuse | |
| 3. Fuse of the circuit board inside the instrument is blown | 3. Replace with a 1.5A fuse | |
| 4. Connecting cable between display screen and motherboard is loose | 4. Secure the connecting wires firmly | |
| After the power is turned on, the display screen lights up, but it does not display any content | 1. Connecting cable between display screen and motherboard is loose | 1. Secure the connecting wires firmly |
| 2. The display screen is broken | 2. Replace the display screen | |
| 3. Communication issue with circuit board | 3. Return to the factory for repair or replacement of the motherboard | |
| Set the knob to be invalid | 1. Knob and mainboard are loose | 1. Properly tighten |
| 2. Knob pressed too tightly/deeply | 2. Pull out and reinstall | |
| 3. Encoder is damaged | 3. Replace the setting knob | |
| Equipment producing abnormal noise | 1. Foreign object inside fan | 1. Open the box and remove foreign objects |
| 2. Equipment fan is damaged | 2. Recommended to replace the fan | |
| No voltage display after connecting battery | 1. Poor contact of battery connection wire | 1. Check if it is plugged in tightly or connected properly |
| 2. Battery connection wire is damaged | 2. Reinsert or replace the connecting cable | |
| 3. Microcontroller cannot detect voltage | 3. Return to factory for repair/replacement | |
| Charging fails after start button is pressed | 1. Microcontroller cannot detect current or switch power supply is damaged | 1. Return to factory for repair/replacement |
| 2. Loose connecting wires | 2. Tighten the connecting wire | |
| 3. Start button is damaged | 3. Replace the start button |
8. Warranty and Support
8.1 Warranty Regulations
- Warranty Period: 1 year from the date of purchase.
- Warranty Coverage: Limited to normal use. Damages caused by human factors, self-disassembly, modification, repair, or use not in accordance with instructions, and damage due to external force majeure are not covered.
- Accessories: Consumable accessories such as test fixtures are not covered by warranty.
- Service Process: For warranty service, please contact your dealer. If the dealer cannot be reached, contact HeltecBMS directly via email or phone.
- International Service: There are no after-sales service stations outside of China. For international warranty service, products must be sent back to HeltecBMS for repair, with the customer responsible for round-trip freight.
8.2 Software Support
The host computer software can be downloaded via a QR code provided in the manual or by contacting customer service for the software link.

9. User Tips
- For optimal accuracy, especially when testing capacity, consider using a smaller discharge current.
- Ensure the device is properly grounded to prevent high voltage hazards.
- When using the PC software, ensure the network firewall is configured correctly or temporarily disabled if connection issues arise.
- Regularly check all connections for tightness to prevent unexpected interruptions during testing.