1. Introduction
The PowMr POW-HVM2H-12V-N is a 2KW 12V Solar Hybrid Inverter designed for off-grid solar energy systems. It integrates an 80A MPPT solar charge controller, a pure sine wave inverter, and a battery charger into one compact unit. This inverter is capable of providing 220V/230V AC power and is compatible with various 12V battery types. It offers multiple charging and load output working modes to optimize energy usage and ensure a reliable power supply for your home or application.

Figure 1.1: PowMr POW-HVM2H-12V-N Solar Hybrid Inverter with key specifications including 12V Battery Voltage, 80A Charging Current, 1600W Rated Output Power, and 30-400Vdc PV Array Voltage Range.
2. Safety Instructions
- Read all instructions and cautionary markings on the unit and the battery before installation and operation.
- Do not disassemble the unit. Refer servicing to qualified personnel.
- Ensure all wiring is performed by a qualified electrician and complies with local electrical codes.
- Never connect the inverter to the utility grid if the utility grid is still active.
- Use insulated tools to prevent electric shock.
- Install the unit in a well-ventilated area, away from flammable materials and corrosive gases.
- Ensure proper grounding of the inverter.
3. Setup and Installation
3.1 Package Contents
Upon unpacking, ensure all items are present and undamaged. The package typically includes:
- PowMr POW-HVM2H-12V-N Solar Hybrid Inverter
- User Manual
- Communication Cable (if applicable)
3.2 Mounting the Inverter
Mount the inverter vertically on a wall or suitable surface. Ensure adequate clearance around the unit for proper ventilation. The dimensions of the inverter are approximately 14.05 inches (height) x 10.75 inches (width) x 3.74 inches (depth).

Figure 3.1: Inverter dimensions (14.05 in H, 10.75 in W, 3.74 in D) and a close-up of the LCD display and function buttons.
3.3 Battery Connection
The inverter is compatible with various 12V battery types. Ensure your battery bank matches the inverter's voltage requirements. The inverter supports:
- LiFePO4 Batteries
- AGM Batteries
- Lithium Batteries
- Flooded Batteries
- Sealed Lead Acid Batteries
- Gel Batteries
For custom battery types, settings may need to be adjusted via the 'User-Defined' option.

Figure 3.2: Visual representation of compatible battery types: LiFePO4, AGM, Lithium, Flooded, Sealed Lead Acid, and Gel Batteries.
3.4 Wiring Diagram
Follow the detailed wiring diagram below for connecting solar panels, batteries, AC input (utility/generator), and AC loads. Pay close attention to cable sizes and torque values for secure and safe connections.

Figure 3.3: Comprehensive wiring diagram showing connections for solar panels (PV VOC: 400Vdc, PV Voltage range: 30-400Vdc, PV Power: 2000W, suggested cable: 16 AWG, torque: 1.2 Nm), generator/utility grid (Max AC Input Voltage: 300Vac, suggested cable: 14 AWG, torque: 1.2 Nm), 12V Lead-acid/Lithium battery (wire size: 1*4AWG, cable: 14mm², torque: 2Nm), and AC load (1600W 230VAC, suggested cable: 14 AWG, torque: 1.2 Nm). Ensure PE protective conductor Ground is connected first.

Figure 3.4: An overview of a typical PV off-grid energy storage system, illustrating the connection of solar panels, the hybrid inverter, batteries (Lead-acid/Lithium), and home appliances, with an option for AC output and solar street lights.
4. Operating Modes
The PowMr hybrid inverter offers flexible operating modes for both charging and load output to suit various energy management needs.
4.1 Charging Modes
You can configure the inverter to prioritize different energy sources for battery charging:
- Solar Charging: Prioritizes solar power for charging batteries.
- Electricity Utility Priority: Prioritizes utility grid power for charging batteries.
- Solar Priority: Prioritizes solar power for charging, using utility only when solar is insufficient.
- Hybrid Charging: Combines solar and utility power for charging.
4.2 Load Output Working Modes
The inverter also allows you to set the priority for powering your loads:
- PV Priority: Loads are primarily powered by solar PV.
- Utility Priority: Loads are primarily powered by the utility grid.
- Inverter Mode: Loads are powered by the inverter (from batteries or solar).

Figure 4.1: Illustration of the four charging modes (Solar Charging, Electricity Utility Priority, Solar Priority, Hybrid Charging) and three load output working modes (PV Priority, Utility Priority, Inverter Mode).
4.3 Output Source Priority Configuration
The inverter allows you to configure the output source priority for your loads:
- Utility Source Power Load as first priority: The utility grid or generator powers the load first.
- Solar power Power Load First: Solar power is used to power the load first.
- Solar+battery Power load at the same time: Solar and battery power the load simultaneously.

Figure 4.2: Diagrams illustrating the three configurable output source priorities: 1) Utility Source (Generator or Utility Grid) as primary, 2) Solar Power as primary, and 3) Solar + Battery power simultaneously.
4.4 WiFi Monitoring (Optional)
The inverter is WiFi monitoring ready. An optional WiFi module (VM-WIFI) can be purchased separately to monitor your system's performance and change parameters in real-time without needing to check the controller's LCD.

Figure 4.3: The inverter is ready for WiFi monitoring, allowing users to monitor the system and change parameters via a smartphone app. Note that the WiFi module is not included in the package and is an optional purchase.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your solar hybrid inverter.
5.1 Cleaning and Inspection
- Periodically clean the exterior of the inverter with a dry cloth.
- Ensure ventilation openings are free from dust and debris.
- Check all connections for tightness and signs of corrosion.
- Inspect cables for any damage or wear.
5.2 Intelligent Cooling Fan
The inverter features an intelligent cooling fan with a built-in sensor chip that adjusts its rotation speed based on ambient temperature and environmental quality. This helps maintain optimal operating temperature and prevents overheating.

Figure 5.1: Illustration of the intelligent cooling fan system, which adjusts fan speed based on ambient temperature and environmental conditions to ensure efficient cooling.
6. Troubleshooting
If you encounter issues with your inverter, refer to the following common troubleshooting steps:
- No Power Output: Check battery connections, AC input (utility/generator), and ensure the inverter is turned on. Verify circuit breakers are not tripped.
- Low Battery Voltage Alarm: Check battery charge level. Ensure solar panels are receiving adequate sunlight and charging correctly.
- Overload Warning: Reduce the connected load. Ensure the total load does not exceed the inverter's rated output power.
- Over-temperature Warning: Ensure proper ventilation around the inverter. Clean any dust from the cooling fan and vents.
- Inverter Not Charging: Check solar panel connections and voltage. Verify utility/generator input is present and stable if using those charging modes.
For persistent issues, consult a qualified technician or contact PowMr customer support.
7. Specifications
Below are the technical specifications for the PowMr POW-HVM2H-12V-N Solar Hybrid Inverter:
| Feature | Specification |
|---|---|
| Model Number | POW-HVM2H-12V-N |
| Battery Voltage | 12V |
| Rated Output Power | 1600W |
| Max PV Array Power | 2000W |
| MPPT Solar Charge Controller Current | 80A |
| PV Array MPPT Voltage Range | 30-400Vdc |
| Output Voltage | 220V/230V (Pure Sine Wave) |
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Output Short Circuit Protection | Circuit Breaker |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
| Application | Home |
| Work Time | 24 hours |
| Certification | CE, RoHS |

Figure 7.1: Detailed inverter specifications table, including input/output voltages, frequencies, protection, efficiency, and transfer time. Also shows an output power derating curve, indicating that output power is derated when AC input voltage drops to 170V.
8. User Tips
- For optimal performance, ensure your battery bank is adequately sized for your daily energy consumption and the inverter's charging capabilities.
- Regularly monitor the LCD display for system status and any warning indicators.
- If using the optional WiFi module, keep the firmware updated for the best monitoring experience.
- Always disconnect power sources before performing any maintenance or wiring adjustments.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official PowMr website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for warranty claims.