The TENSTAR SHT41 is a high-accuracy digital sensor module designed for measuring relative humidity and temperature. Utilizing I2C communication, this module offers reliable performance with an ultra-low power budget, making it suitable for a wide range of applications including environmental monitoring, smart home devices, and industrial control systems. The SHT41 is part of the SHT4x series, representing the 4th generation of Sensirion's humidity and temperature sensors.

Figure 1: Front and back view of the SHT41 module with its accompanying pin header.
2. Specifications
2.1 General Specifications
- Brand: TENSTAR ROBOT
- Model: SHT41 (GY-SHT41)
- Type: Module
- Communication Interface: I2C
- Supply Voltage (VDD): 1.08 V - 3.6 V
- Dissipation Power: 1
- Average Current: 0.4 µA
- Idle Current: 80 nA
- Operating Temperature Range: -40 °C to 125 °C (-30 °C to +50 °C as per product properties)
- Operating Humidity Range: 0 %RH to 100 %RH
- Package: SOP (Small Outline Package)
- Dimensions: Approximately 10.2mm x 13mm
- Condition: New
- Application: Computer (General purpose for embedded systems)
2.2 Performance Highlights
- Relative Humidity Accuracy: ΔRH = ±1.0 %RH
- Temperature Accuracy: ΔT = ±0.1 °C
- I2C Features: Fast Mode Plus (FM+), CRC checksum, multiple I2C addresses
- Environmental Robustness: Fully functional in a condensing environment
- Heater: Power-trimmed internal heater with three heating levels
- Traceability: True NIST-traceability
- Qualification: JESD47 qualified
- Calibration: Sensor-specific calibration certificate according to ISO 17025:2017, 3-point temperature calibration
- Protection: Optional on-package patented PTFE membrane or removable protective cover (depending on specific SHT4x variant)
2.3 Device Overview (SHT4x Series)
| Product | Details |
|---|---|
| SHT40-AD1B | Base RH&T accuracy, 0x44 I2C address |
| SHT40-BD1B | Base RH&T accuracy, 0x45 I2C address |
| SHT40-AD1F | SHT40-AD1B with PTFE membrane |
| SHT40-AD1P | SHT40-AD1B with protective cover |
| SHT41-AD1B | Intermediate RH&T accuracy, 0x44 I2C address |
| SHT43-ADCB | ISO17025 3-point calibration certificate |
| SHT45-AD1B | ±1.0 %RH, ±0.1 °C accuracy, 0x44 I2C address |
Note: The specific model covered by this manual is SHT41-AD1B.
3. Setup and Connection
3.1 Pinout Diagram
The SHT41 module features a 4-pin interface for power and I2C communication. Refer to the diagram below for pin identification:

Figure 2: SHT41 module pinout and dimensions.
- VIN: Voltage Input (Power Supply, 1.08V - 3.6V)
- GND: Ground
- SCL: I2C Serial Clock Line
- SDA: I2C Serial Data Line
3.2 Connecting the Module
To integrate the SHT41 module into your system, follow these steps:
- Power Connection: Connect the VIN pin to your system's power supply (within 1.08V to 3.6V) and the GND pin to the system's ground.
- I2C Connection: Connect the SCL pin to your microcontroller's I2C clock line and the SDA pin to your microcontroller's I2C data line. Ensure that appropriate pull-up resistors are used on the SCL and SDA lines, typically 4.7kΩ, if not already present on your microcontroller board.
- Physical Mounting: Secure the module to your PCB or prototyping board. Consider the module's small dimensions (10.2mm x 13mm) for placement.
4. Operating Instructions
4.1 I2C Communication
The SHT41 communicates via the I2C protocol. The default I2C address for the SHT41-AD1B is 0x44. Your microcontroller will need to be programmed to send and receive data using this address.
- Read Temperature and Humidity: The sensor provides digital output for both temperature and relative humidity. Consult the SHT4x datasheet (available from Sensirion) for specific I2C commands and data formats to initiate measurements and read the results.
- CRC Checksum: The SHT41 supports CRC checksums for data integrity verification, which is highly recommended for reliable communication.
4.2 Power Heater Functionality
The SHT41 includes an internal power heater that can be activated at three different levels. This feature is useful for:
- Condensation Prevention: Heating the sensor can prevent condensation from forming on the sensor element in high humidity environments, ensuring accurate readings.
- Sensor Cleaning: Brief activation of the heater can help to evaporate contaminants from the sensor surface.
Refer to the SHT4x datasheet for detailed instructions on how to enable and control the heater levels via I2C commands.
5. Maintenance
The SHT41 module is designed for long-term stability and typically requires minimal maintenance. However, consider the following:
- Environmental Protection: If your SHT41 module includes an optional PTFE membrane or protective cover, ensure it remains intact to shield the sensor from dust and contaminants.
- Cleaning: Avoid direct contact with the sensor element. If cleaning is necessary, use dry, compressed air or a soft brush to gently remove dust. Do not use liquids or solvents.
- Recalibration: The SHT41 is factory-calibrated and comes with a sensor-specific calibration certificate. Under normal operating conditions, recalibration is generally not required. If extreme accuracy is critical after prolonged use or exposure to harsh conditions, consult Sensirion's guidelines for recalibration.
6. Troubleshooting
- No I2C Communication:
- Verify power supply (VIN and GND) is correctly connected and within the 1.08V - 3.6V range.
- Check I2C wiring (SCL, SDA) for continuity and correct connections.
- Ensure I2C pull-up resistors are present and correctly sized (e.g., 4.7kΩ).
- Confirm the correct I2C address (0x44 for SHT41-AD1B) is used in your code.
- Check for I2C bus conflicts if other I2C devices are connected.
- Inaccurate Readings:
- Ensure the sensor is not exposed to direct sunlight, heat sources, or strong air currents, which can affect readings.
- Check for condensation on the sensor element. Use the internal heater if operating in high humidity.
- Verify that your software is correctly interpreting the raw sensor data according to the SHT4x datasheet.
- Ensure the sensor is placed in an environment representative of the area you wish to measure.
- Module Not Responding:
- Power cycle the module and your microcontroller.
- Inspect the module for any visible damage.
7. User Tips
- For optimal accuracy, allow the sensor to stabilize in its operating environment for a few minutes after power-up.
- When prototyping, use a breadboard-friendly adapter or solder the included pin header for easier connections.
- Always refer to the official Sensirion SHT4x datasheet for the most detailed and up-to-date technical information and programming guides.
- Consider using a dedicated I2C library for your chosen microcontroller platform (e.g., Arduino, Raspberry Pi) to simplify integration.
8. Warranty and Support
For technical support, documentation, or inquiries regarding your TENSTAR SHT41 module, please contact the seller or TENSTAR ROBOT directly. Keep your purchase records for any warranty claims. Specific warranty terms may vary by region and seller.