1. Introduction
The TENSTAR ROBOT GY-SHT41 is a high-accuracy digital sensor module designed for precise measurement of relative humidity and temperature. Utilizing I2C communication, this module offers reliable performance in various applications, including those in condensing environments. It features a low power budget and comes with a PTFE membrane for protection, ensuring durability and consistent readings.
2. Features
- Digital temperature and humidity sensing.
- I2C communication interface.
- High accuracy: ΔRH = ±1.0 %RH, ΔT = ±0.1 °C.
- Wide operating voltage range: 1.08 V to 3.6 V.
- Low average current consumption: 0.4 µA (80 nA idle current).
- Fully functional in condensing environments.
- Integrated power heater.
- True NIST-traceability and JEDEC JESD47 qualification.
- Sensor-specific calibration certificate according to ISO 17025:2017, 3-point temperature calibration.
- Equipped with a PTFE membrane and removable protective cover.
3. Specifications
| Attribute | Value |
|---|---|
| Type | Temperature Sensor, Humidity Sensor |
| Output | Digital Sensor |
| Theory | Resistance Sensor |
| Material | Mixture |
| Origin | Mainland China |
| Humidity Accuracy | ±1.0 %RH |
| Temperature Accuracy | ±0.1 °C |
| Supply Voltage (VDD) | 1.08 V - 3.6 V |
| Average Current | 0.4 µA |
| Idle Current | 80 nA |
| I2C Features | I2C FM+, CRC checksum, multiple I2C addresses |
| Operating Range (RH) | 0 ... 100 %RH |
| Operating Range (Temp) | -40 ... 125 °C |
| Module Dimensions | 15mm x 15mm (approx.) |
| Package Weight | 0.002 kg |
| Package Dimensions | 8cm x 6cm x 1cm |
Datasheet Highlights and Functional Block Diagram
The image below provides key information from the SHT41 datasheet, including pinout details, physical dimensions, and a functional block diagram illustrating the internal components and their connections.

Image: SHT41 Datasheet Highlights - Pinout, Dimensions, Features, and Functional Block Diagram. This diagram shows the RH Sensor, T Sensor, ADC, Calibration Memory, Heater, Reset, Register, VDD, VSS, SDA, and SCL connections.
4. Setup
4.1 Pinout
The SHT41 sensor module features a standard 4-pin interface for power and I2C communication. Refer to the image below for pin identification:
- VIN: Voltage Input (Power Supply)
- GND: Ground
- SCL: I2C Clock Line
- SDA: I2C Data Line

Image: Front view of the SHT41 sensor module clearly showing the VIN, GND, SCL, and SDA pin labels.
4.2 Physical Dimensions
The SHT41 module is compact, making it suitable for space-constrained applications. Its small size is demonstrated in the image below.

Image: The SHT41 sensor module held between fingers, highlighting its compact form factor.
4.3 Electrical Connection
- Connect the VIN pin of the SHT41 module to your microcontroller's 3.3V or 5V power supply (within the 1.08V-3.6V operating range).
- Connect the GND pin of the SHT41 module to the ground of your microcontroller.
- Connect the SCL pin of the SHT41 module to the I2C clock pin of your microcontroller.
- Connect the SDA pin of the SHT41 module to the I2C data pin of your microcontroller.
- Ensure appropriate pull-up resistors are used on the SCL and SDA lines if not already integrated into your microcontroller or development board.
5. Operating Instructions
The SHT41 communicates via the I2C protocol. To operate the sensor, you will need to send commands and read data over the I2C bus from your microcontroller (e.g., Arduino, ESP32, Raspberry Pi).
5.1 I2C Communication Basics
- The SHT41 operates as an I2C slave device.
- It supports I2C Fast Mode Plus (FM+).
- The sensor has a default I2C address (refer to the SHT41 datasheet for the specific address).
- Data is transmitted with CRC checksums for integrity verification.
5.2 Reading Temperature and Humidity
Typically, the process involves:
- Sending a measurement command to the SHT41 via I2C.
- Waiting for the sensor to complete the measurement (a short delay may be required).
- Reading the raw temperature and humidity data from the sensor via I2C.
- Converting the raw digital values into meaningful temperature (°C or °F) and relative humidity (%RH) values using the formulas provided in the SHT41 datasheet.
Many microcontroller libraries are available for the SHT4x series sensors, which simplify the I2C communication and data conversion process.
6. Maintenance
- Environmental Protection: The SHT41 features a PTFE membrane and a removable protective cover. Ensure these are in place to protect the sensor from dust and contaminants, especially in harsh environments.
- Cleaning: If necessary, gently clean the exterior of the module with a soft, dry cloth. Avoid using liquids or abrasive materials directly on the sensor element.
- Storage: Store the module in a dry, non-condensing environment within its specified storage temperature and humidity ranges when not in use.
- Avoid Mechanical Stress: Handle the module with care to prevent physical damage to the sensor element or pins.
7. Troubleshooting
- No Readings / I2C Communication Failure:
- Verify all electrical connections (VIN, GND, SCL, SDA) are correct and secure.
- Ensure the power supply voltage is within the specified range (1.08V - 3.6V).
- Check for proper I2C pull-up resistors on SCL and SDA lines.
- Confirm the I2C address used in your code matches the sensor's address.
- Test with a known working I2C device to rule out microcontroller I2C issues.
- Inaccurate Readings:
- Ensure the sensor is not exposed to direct sunlight, heat sources, or strong airflow, which can affect local readings.
- Allow sufficient time for the sensor to stabilize after power-up or environmental changes.
- Verify that the data conversion formulas in your code are correct according to the SHT41 datasheet.
- Check for any physical obstructions or contamination on the sensor element.
- Condensation Issues:
- While the SHT41 is designed for condensing environments, prolonged exposure to extreme condensation might temporarily affect readings. Ensure the PTFE membrane is intact.
- Utilize the integrated heater function if available in your application to evaporate condensation.
8. User Tips
- Software Libraries: For ease of use, consider utilizing existing SHT4x sensor libraries available for popular development platforms like Arduino or CircuitPython. These libraries often handle I2C communication and data conversion automatically.
- Power Management: To maximize battery life in portable applications, take advantage of the sensor's low idle current and put it into sleep mode between measurements.
- Calibration: Although factory calibrated, for highly critical applications, consider performing a two-point calibration in your specific environment to fine-tune accuracy.
- Environmental Placement: For the most accurate ambient readings, place the sensor away from heat-generating components, direct sunlight, and areas with restricted airflow.
9. Warranty and Support
For any technical assistance, warranty claims, or support inquiries regarding your TENSTAR ROBOT GY-SHT41 sensor module, please contact the seller or manufacturer directly through the platform where the product was purchased. Ensure you have your purchase details readily available.