Instruction Manual

1. Product Overview

The Runxin F67Q series automatic multiport filter valves are designed for water treatment systems, offering efficient control over service, backwash, and fast rinsing functions. These valves are characterized by a flow rate of 4m³/h and utilize a planar, corrosion-resistant gasket for reliable opening and closing. The F67Q series includes two main models:

  • F67Q1 (Model 55504): A time-controlled regeneration type valve.
  • F67Q3 (Model 55604): A meter-controlled regeneration type valve.

Both models allow for easy modification of parameters to suit specific operational needs.

Front view of the Runxin F67Q automatic filter valve control panel.
Figure 1: Front view of the F67Q Control Panel

2. Specifications

Attribute Specification
Model F67Q1 (55504) / F67Q3 (55604)
Regeneration Type Time clock type (F67Q1) / Meter type (F67Q3)
Mount Type Top mount
Inlet/Outlet 1"F
Drain 1"F
Mounting Base 2.5"-8NPSM
Riser Pipe 1.05"OD
Flow Rate 4m³/h
Filter Tank Compatibility 6"-12"
Water Pressure 0.15-0.6MPa
Water Temperature 5-50℃
Water Turbidity <20FTU
Power Adapter Input AC100~240V/50~60HZ Output DC12V/1.5A
Application Activated carbon filter, sand filter
Filter Media Quartz sand, activated carbon
Weight 2.5 kg
Size (L*W*H) 26*23.5*21.5 cm

3. Setup Instructions

  1. Unpacking: Carefully remove the valve and all accessories from the packaging. Verify all components are present: valve head, power adapter, and any included fittings (refer to Figure 4).
  2. Mounting: The valve is designed for top-mount installation on a compatible filter tank (6"-12" diameter) with a 2.5"-8NPSM mounting base. Ensure the riser pipe (1.05"OD) is correctly inserted into the tank and valve.
  3. Plumbing Connections:
    • Connect the water inlet to the designated 1"F inlet port.
    • Connect the treated water outlet to the designated 1"F outlet port.
    • Connect the drain line to the 1"F drain port. Ensure all connections are secure and leak-free.
  4. Power Connection: Connect the provided AC100~240V/50~60HZ power adapter to the valve and then to a suitable power outlet. The output is DC12V/1.5A.
  5. Initial Programming (Refer to Operating Instructions): Before first use, the valve may require initial programming for time (F67Q1) or meter settings (F67Q3) and regeneration cycles.
Runxin F67Q valve with included power adapter and accessories.
Figure 2: Valve with Power Adapter and Accessories

4. Operating Instructions

The F67Q valve offers various operational modes, which can be selected and configured via the control panel. The primary functions include Service, Backwash, and Fast Rinse.

Diagram illustrating the different operational modes (Service, Backwash, Fast Rinse) of the F67Q valve.
Figure 3: Operational Modes Diagram
Detailed internal flow path diagram for the F67Q valve during various cycles.
Figure 4: Internal Flow Path Diagram

4.1. Control Panel Overview

The control panel features a digital display and buttons for navigation and setting adjustments. Specific indicators will light up to show the current operational stage (Service, Backwash, Fast Rinse).

4.2. F67Q1 (Time Control) Operation

This model initiates regeneration based on a preset time interval. Users can program the frequency and time of regeneration cycles. Consult the detailed programming guide (usually included with the product) for specific steps to set the current time and regeneration schedule.

4.3. F67Q3 (Meter Control) Operation

This model initiates regeneration based on the volume of water processed. Users can set the desired water volume between regenerations. The valve's internal meter tracks water usage and triggers regeneration once the set volume is reached. Consult the detailed programming guide for specific steps to set the meter volume and regeneration parameters.

4.4. Manual Regeneration

Most automatic valves allow for manual initiation of a regeneration cycle. Refer to your specific model's manual for the button sequence or menu option to start a manual regeneration.

4.5. Adjusting Parameters

The control panel allows for modification of various parameters such as regeneration duration for each step (backwash, fast rinse), and time/volume settings. Use the 'Up' and 'Down' buttons to navigate and adjust values, and the 'Set' or 'Enter' button to confirm changes.

Video 1: Product Overview and Demonstration

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your Runxin F67Q valve.

  • Regular Cleaning: Periodically clean the exterior of the valve with a soft, damp cloth. Avoid abrasive cleaners.
  • Gasket Inspection: The valve uses a planar, corrosion-resistant gasket. Inspect it during any disassembly for signs of wear or damage. Replace if necessary to prevent leaks.
  • Power Supply Check: Ensure the power adapter is securely connected and free from damage.
  • Filter Media Replacement: The valve controls the regeneration of filter media (e.g., quartz sand, activated carbon). Follow the recommendations for your specific filter media regarding replacement or replenishment intervals.
  • Winterization (if applicable): If the system is in an area subject to freezing temperatures, ensure the valve and associated plumbing are properly drained and protected to prevent freeze damage.

6. Troubleshooting

This section provides solutions to common issues. For more complex problems, contact technical support.

6.1. No Power to the Valve

  • Check Power Adapter: Ensure the power adapter is correctly plugged into both the valve and a working electrical outlet.
  • Verify Outlet: Test the electrical outlet with another device to confirm it is supplying power.
  • Inspect Wiring: Check for any visible damage to the power cord or connections.

6.2. Valve Not Regenerating

  • F67Q1 (Time Control): Verify the programmed regeneration time and frequency. Ensure the current time is set correctly.
  • F67Q3 (Meter Control): Check if the set water volume for regeneration has been reached. Ensure the flow meter is functioning correctly.
  • Manual Regeneration: Attempt to initiate a manual regeneration cycle to see if the valve responds.

6.3. Water Leaks

  • Check Connections: Tighten all plumbing connections (inlet, outlet, drain). Do not overtighten.
  • Inspect Gaskets/O-rings: Examine the internal gaskets and O-rings for proper seating or damage. Replace if worn.

6.4. Low Flow Rate After Regeneration

  • Insufficient Backwash: The backwash cycle might be too short or the water pressure too low during backwash. Adjust settings or check water supply pressure.
  • Clogged Drain Line: Ensure the drain line is not obstructed, which can impede proper backwash.

7. User Tips

Based on general feedback for similar products, consider the following tips for optimal performance:

  • Regularly Monitor Performance: Keep an eye on your water quality and system flow rates. Any significant changes might indicate a need for maintenance or adjustment.
  • Understand Regeneration Cycles: Familiarize yourself with the different stages of regeneration (Service, Backwash, Fast Rinse) and their durations to ensure efficient operation.
  • Keep a Log: For meter-controlled valves (F67Q3), tracking your water usage and regeneration frequency can help optimize settings and anticipate media replacement.
  • Power Outage Considerations: In case of a power outage, some settings might need to be re-entered or verified once power is restored. Consult the specific product manual for power loss recovery procedures.

8. Warranty and Support

The Runxin F67Q1/F67Q3 Automatic Filter Valve comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use conditions.

For warranty claims, technical assistance, or further inquiries, please contact your authorized dealer or the manufacturer's customer service. Please have your purchase receipt and product model number (F67Q1 or F67Q3) available when contacting support.

For additional information and resources, you may refer to the official Runxin website or contact the seller directly.

EAC and CE certification documents for the Runxin F67Q valve.
Figure 5: Product Certifications (EAC, CE)

© 2024 Runxin. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.