1. Safety Information
WARNING: Disconnect the power supply before wiring.
- This device operates at high voltage (Above 50Vac or 75Vdc). Ensure all power is disconnected before installation or maintenance to prevent electric shock.
- Installation should be performed by a qualified electrician in accordance with local electrical codes.
- Do not operate the device if it is damaged or malfunctioning.
- Ensure proper grounding if required by your electrical system.
2. Product Overview
The VaneAims Adjustable Voltage Current Protector is designed to safeguard electrical equipment from voltage fluctuations and overcurrent conditions. It features automatic recovery, ensuring power is restored once conditions return to normal. Various versions offer different display and measurement capabilities.
The device protects against:
- Overvoltage: Disconnects power when voltage exceeds a set threshold.
- Undervoltage: Disconnects power when voltage drops below a set threshold.
- Overcurrent: Disconnects power when current exceeds a set threshold.
- Automatic Recovery: Automatically reconnects power once voltage and current return to safe operating ranges after a set delay.
Product Demonstration Video
Video 1: Demonstration of VaneAims Adjustable Voltage Current Protector features and function tests, including overvoltage, undervoltage, and overcurrent protection.
3. Specifications
The following table outlines the general technical parameters for the VaneAims Adjustable Voltage Current Protector. Specific models may have slight variations in voltage setting ranges and maximum current, as detailed in their respective instruction sections.
| Parameter | Value |
|---|---|
| Supply Terminals | N, L |
| Rated Supply Voltage | AC 220V |
| Rated Frequency | 40/50/60/70Hz (varies by model) |
| Overvoltage Setting Range (>V) | AC130-300V or AC240-300V (adjustable) |
| Undervoltage Setting Range (<V) | AC80-210V or AC140-230V (adjustable) |
| Voltage Hysteresis | 5V |
| Overvoltage Trip Delay | 0.5s |
| Voltage Accuracy | <1% |
| Max. Operating Phase Voltage | 350V |
| Max. Operating Current | 40A/63A/80A/100A (adjustable, varies by model) |
| Altitude | ≤2000m |
| Permissible Relative Humidity | ≤50% at 40℃ (without condensation) |
| Ambient Temperature | -25℃ ~ +55℃ |
| Size | 81*36*66mm |
4. Setup
4.1. Installation
The protector is designed for 35mm DIN rail installation and can be placed in household distribution boxes. It is equivalent in size to a regular 2P circuit breaker.
4.2. Wiring
Follow the wiring diagram carefully. Ensure the power line is input through the L (Live) and N (Neutral) terminals. Screw down to penetrate the insulating layer of the power lines for secure connection.
4.3. Initial Power-On
Upon successful wiring and power-on, the device will display real-time voltage and current values. Depending on the model, it may also display power (W), frequency (Hz), and accumulated electricity consumption (kWh).
5. Operating Instructions
The device features a 'SET' button and 'Up'/'Down' arrow buttons for parameter configuration. Long press the 'SET' button for 5 seconds to enter the setup menu. Use the 'Up' and 'Down' keys to navigate through parameters and adjust values. Press 'SET' again to save changes.
5.1. Setup Menu Parameters (General)
The following are common parameters found across different models. Refer to the specific setup menu diagrams for your model for exact parameter numbers and ranges.
- P-1: Power-on delay time (1s-999s)
- P-2: Recovery delay (1s-999s)
- P-3: Overvoltage Setting (e.g., AC130-300V, AC240-300V)
- P-4: Overvoltage recovery value (e.g., 125V-295V)
- P-5: Undervoltage Setting (e.g., AC80-210V, AC140-230V)
- P-6: Undervoltage recovery value (e.g., 85V-215V)
- P-7: Voltage trip delay (0.1s-10s)
- P-8: Voltage Correction (-10%~+10%V)
- P-9: Overcurrent Setting (e.g., 1A-40/63/80/100A)
- P-10: Overcurrent trip delay (0.1s-10s)
- P-11: Overcurrent counter (0-20 times)
- P-12: Current adjustment (-10%~+10%A)
- P-13: Frequency adjustment (-2.5%~+2.5%Hz)
- P-14: Quick power down protection (on/off)
- P-15: Three models (1:Standard, 2:Manual, 3:Automatic)
- P-16: Automatic reset (on/off)
- P-17: Switch mode (on/off)
- P-18: Energy saving mode (on/off)
- P-19: Password setting (000-999, default: 112)
Note: To quickly adjust figures for longer periods, press and hold either the 'Up' or 'Down' key.
5.2. Display Modes
The display varies by model:
- Regular Version (FXB-VA) & Upgraded Version (FXB-VALG): Displays Voltage (V) and Current (A).
- kWh Version (FXB-VAKWH): Displays Voltage (V), Current (A), and accumulated Electricity (kWh).
- All-in-One Version (FXB-VA5+1): Displays Voltage (V), Current (A), accumulated Electricity (kWh), Power (W), and Frequency (Hz).
6. Maintenance
6.1. Screen Protective Film
The screen surface is covered with a factory protective film. Slight bubbles or scratches may occur during transportation. This is normal.
Usage Tip: Please remove the protective film promptly after receiving the goods to achieve the best display effect.
6.2. General Care
- Keep the device clean and free from dust and moisture.
- Do not use abrasive cleaners or solvents.
- Ensure proper ventilation around the device.
7. Troubleshooting
7.1. Device Disconnection / Power Stopped
If the protector disconnects the power supply, it indicates that the voltage or current has exceeded the set thresholds (overvoltage, undervoltage, or overcurrent). The device will automatically reconnect power after the set recovery delay once the conditions return to normal operating ranges.
Refer to the operating instructions to verify your set parameters (P-3 to P-6 for voltage, P-9 for current) are appropriate for your application.
7.2. Current Value Not Displayed
The current value may not be displayed when the actual current is below 1A. This is a normal operational characteristic of the device.
7.3. Cumulative Power Consumption Not Displayed
For kWh and All-in-One versions, the cumulative power consumption (kWh) may not be displayed if the value is below 0.01 kWh.
8. User Tips
- The device is designed to operate in a wide temperature range (-25°C to +55°C), making it suitable for various environments.
- Always ensure the screen's protective film is removed upon receipt for optimal display clarity.
- For precise parameter adjustments, use short presses of the 'Up' and 'Down' buttons. For faster adjustments over a wider range, press and hold the buttons.
9. Frequently Asked Questions (FAQ)
Q: Does this device provide short-circuit protection?
A: This device primarily offers overvoltage, undervoltage, and overcurrent protection. While overcurrent protection can help mitigate some effects of a short circuit, dedicated short-circuit protection is typically provided by circuit breakers in your electrical panel. This protector is designed to work in conjunction with existing circuit protection, not replace it.
Q: Does the device automatically restore power after an undervoltage event?
A: Yes, a key feature of this protector is its automatic recovery function. When the voltage returns to the desired operating levels after an undervoltage event, the device will automatically restore power after a user-configurable delay (P-2: Recovery delay).
10. Warranty and Support
For warranty information, technical support, or any inquiries regarding your VaneAims Adjustable Voltage Current Protector, please contact the seller or manufacturer directly. Keep your purchase records for reference.