DATOUBOSS LFP48-300-FSD

Contents

DATOUBOSS LFP48-300-FSD 15Kwh LiFePO4 Battery User Manual

Model: LFP48-300-FSD | Brand: DATOUBOSS

1. Introduction

The DATOUBOSS LFP48-300-FSD is a high-capacity, IP65 waterproof lithium iron phosphate (LiFePO4) battery designed for various energy storage applications, including home solar systems, off-grid setups, yachts, and RVs. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your battery system.

2. Safety Information

Always prioritize safety when handling and installing the battery. Failure to follow safety instructions can result in serious injury or damage to the equipment.

  • Ensure all connections are secure and correctly polarized.
  • Do not expose the battery to extreme temperatures or direct sunlight for prolonged periods.
  • Keep the battery away from flammable materials.
  • Only qualified personnel should perform installation and maintenance.
  • The integrated Battery Management System (BMS) provides multiple protections, but proper handling is still crucial.
DATOUBOSS LiFePO4 Battery with safety shield icon
Figure 2.1: Safe & Reliable design with multiple protection features.

3. Package Contents

Upon receiving your DATOUBOSS LFP48-300-FSD battery, carefully inspect the package for any damage. Ensure all items listed below are present.

DATOUBOSS LiFePO4 Battery and included accessories
Figure 3.1: Main unit and accessories included in the package.
  • 1 x DATOUBOSS Lithium-ion Battery (Model: LFP48-300-FSD, 15.36kWh, 51.2V/300Ah)
  • 1 x Instruction Manual
  • 1 x Mounting Bracket
  • 1 x Wall-Mount Bracket
  • Bolts (various sizes for mounting)
  • Screws (various sizes for mounting)
  • Red Insulating Sleeves
  • Black Insulating Sleeves
  • Small Nuts
  • 1 x Yellow Network Cable (Communication cable)
  • 1 x Red-black Cable (Positive/Negative Battery Connection Cable)
  • 1 x Metal Bracket
  • 1 x Product Specification Label

4. Product Overview

The DATOUBOSS LFP48-300-FSD battery features a robust design with clear indicators and accessible connection ports.

DATOUBOSS LiFePO4 Battery dimensions
Figure 4.1: Battery dimensions: 45cm (17.7in) L x 26cm (10.2in) W x 86cm (33.8in) H.
DATOUBOSS LiFePO4 Battery front and side panel details
Figure 4.2: Detailed view of the battery's front and side panels, showing ports, indicators, and switches.

4.1. Front Panel Components

  • **LCD Display (13):** Provides real-time monitoring of battery status, voltage, current, capacity, and other parameters.

4.2. Top Panel Components

  • **Alarm Indicator (1):** Indicates system warnings or errors.
  • **Operation Indicator (2):** Shows normal operating status.
  • **Switching Indicator (3):** Indicates the state of the internal switching mechanism.
  • **Dry Contact (4):** For external control or monitoring.
  • **Reset Switch (5):** Used to reset the battery system.
  • **DIP Address (6):** For setting communication addresses in parallel configurations.
  • **Battery Indicator (7):** Displays battery charge level.
  • **CAN (8):** Communication port for host computer or inverter.
  • **RS232 (9):** Communication port for parallel communication.
  • **RS485 (10):** Communication port for host computer or inverter, and parallel communication.
  • **Battery Negative (11):** Negative terminal for power connection.
  • **Battery Positive (12):** Positive terminal for power connection.

4.3. Side Panel Components

  • **Push Button Switch (14):** Main power button.
  • **Air Switch (15):** Circuit breaker for safety and isolation.
Interface Definition Table for DATOUBOSS LiFePO4 Battery
Figure 4.3: Interface Definition Table for RS485, CAN, and RS232 ports, including PIN descriptions.

5. Installation Instructions

The DATOUBOSS LFP48-300-FSD battery offers flexible installation options, including wall-mounting or placement on rollers for mobility.

DATOUBOSS LiFePO4 Battery with wall-mount and roller options
Figure 5.1: Flexible installation options: wall-mounted or mobile with rollers.

5.1. Unpacking and Inspection

  1. Carefully remove the battery and all accessories from the packaging.
  2. Inspect the battery unit and all components for any signs of physical damage. Do not proceed with installation if damage is found.
  3. Verify that all items listed in the "Package Contents" section are present.

5.2. Site Selection

  • Choose a location that is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.
  • Ensure the surface is strong enough to support the battery's weight (110kg).
  • Maintain adequate clearance around the battery for ventilation and access (e.g., 50cm/19.6in above and below, 20cm/7.8in on sides for wall-mount).

5.3. Mounting the Battery

The battery can be wall-mounted using the provided brackets or placed on a flat surface using its integrated rollers.

5.3.1. Wall-Mount Installation

  1. Mark the drilling points on the wall according to the wall-mount bracket.
  2. Drill holes and insert appropriate anchors (if necessary).
  3. Securely attach the wall-mount bracket to the wall using the provided bolts and screws.
  4. Carefully lift the battery and hang it onto the wall-mount bracket. Ensure it is securely seated.

5.3.2. Floor Placement (with Rollers)

  1. Ensure the chosen floor location is level and stable.
  2. Roll the battery into position. The rollers allow for convenient movement.
  3. Once in place, engage the locks on the rollers to prevent unintended movement.

5.4. Electrical Connections

Refer to the schematic diagram for a typical home solar energy storage system connection. Ensure all connections are made by a qualified electrician.

Schematic Diagram of Home Solar Energy Storage System
Figure 5.2: Schematic diagram illustrating the connection of the battery within a home solar energy storage system, including photovoltaic modules, generator, power grid, and various loads.
  1. **Connect Battery Cables:** Connect the provided red-black cables to the Battery Positive (12) and Battery Negative (11) terminals. Ensure correct polarity. Connect the other ends to your inverter or charge controller.
  2. **Communication Cable Connection:** Connect the yellow network cable to the appropriate communication port (CAN, RS232, or RS485) on the battery and to your inverter/monitoring system. Refer to the "Interface Definition Table" (Figure 4.3) for PIN details.
  3. **Parallel Connection (Optional):** If connecting multiple batteries in parallel (up to 15 units), ensure DIP switch settings are correctly configured for each unit and use the appropriate RS485 communication ports for parallel communication.
  4. **Grounding:** Ensure the battery system is properly grounded according to local electrical codes.

WARNING: Incorrect wiring can cause severe damage to the battery and connected equipment, and poses a risk of electric shock. Always consult a qualified professional.

6. Operating Instructions

6.1. Initial Startup

  1. After all electrical connections are securely made, ensure the Air Switch (15) on the side panel is in the 'OFF' position.
  2. Turn on the external inverter or charge controller.
  3. Flip the Air Switch (15) to the 'ON' position.
  4. Press the Push Button Switch (14) to power on the battery.
  5. The LCD Display (13) will illuminate, showing the battery's status.

6.2. LCD Display and Monitoring

The color touch screen LCD display provides real-time monitoring and allows you to navigate through various pages to view battery parameters.

DATOUBOSS LiFePO4 Battery real-time monitoring touch screen
Figure 6.1: Real-time monitoring with the color touch screen, displaying voltage, current, capacity, power, and state.
  • **Voltage/V:** Current battery voltage.
  • **Capacity:** Remaining battery capacity percentage.
  • **Current/A:** Charging (CHG) or Discharging (DSG) current.
  • **Power:** Instantaneous power output/input.
  • **State:** Current operational state (e.g., charging, discharging, idle).
  • Navigate through the menu using the touch screen to access master/slave settings, parameters, protocol settings, and general settings.

6.3. Normal Operation

  • The battery will automatically charge when connected to a power source (e.g., solar panels via a charge controller) and discharge to power connected loads.
  • Monitor the LCD display for any alarm indicators or unusual readings.
  • The battery is designed for continuous operation in various scenarios.
DATOUBOSS LiFePO4 Battery applications: Home Storage, Off-Grid, Yacht, RV & Car
Figure 6.2: The battery is widely used in multiple scenarios such as home storage, off-grid systems, yachts, and RVs.

6.4. Shutdown Procedure

  1. Ensure no critical loads are drawing power from the battery.
  2. Press and hold the Push Button Switch (14) until the battery powers off.
  3. Flip the Air Switch (15) to the 'OFF' position.
  4. Turn off the external inverter or charge controller.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your DATOUBOSS LiFePO4 battery.

7.1. General Care

  • Keep the battery clean and free from dust and debris.
  • Ensure ventilation openings are not obstructed.
  • Periodically check all electrical connections for tightness and corrosion.
  • Avoid exposing the battery to extreme temperatures outside its operating range (-10°C to 50°C).

7.2. Battery Management System (BMS)

The integrated Smart BMS provides comprehensive protection for the battery, including:

  • Overcurrent Protection
  • Overheating Protection
  • Rectification Protection
  • Electrical Protection
  • Overdischarge Protection
  • Overcharge Protection
BMS Intelligent Protection features
Figure 7.1: The BMS offers intelligent protection against various electrical faults and conditions.

7.3. Cycle Life

The battery is designed for a long lifespan:

  • ≥8000 cycles at 25°C with 70% State of Health (SOH)
  • ≥3000 cycles at 45°C with 70% State of Health (SOH)
8000+ cycle life illustration
Figure 7.2: Illustration of the battery's extended cycle life, reducing replacement costs.

8. Troubleshooting

This section addresses common issues you might encounter. For problems not listed here or if solutions do not resolve the issue, please contact customer support.

ProblemPossible CauseSolution
Battery does not power on.Air Switch is OFF.
Push Button Switch not pressed.
No input power.
Ensure Air Switch is ON.
Press Push Button Switch.
Check input power source and connections.
Alarm Indicator is lit.Overcharge/Overdischarge.
Overcurrent.
Temperature anomaly.
Check LCD for specific error code. Disconnect loads/charge source if necessary. Allow battery to cool down if overheating. If issue persists, contact support.
Battery not charging.Charging source issue.
Temperature too low/high.
BMS protection activated.
Verify charging source (solar panels, grid). Ensure ambient temperature is within charging range (0°C to 50°C). Check LCD for BMS status.
Battery not discharging.Load issue.
Battery fully discharged.
BMS protection activated.
Check connected loads. Ensure battery has sufficient charge. Check LCD for BMS status. Ensure ambient temperature is within discharging range (-15°C to 50°C).

9. User Tips

  • **Optimal Performance:** For best battery life and performance, try to keep the battery operating within its recommended temperature range.
  • **Regular Monitoring:** Periodically check the LCD display for battery health and performance metrics. This can help identify potential issues early.
  • **Firmware Updates:** If available, ensure your battery's firmware is up-to-date for improved performance and bug fixes. Consult the manufacturer's website or support for details.

10. Specifications

Detailed technical specifications for the DATOUBOSS LFP48-300-FSD battery.

ParameterSpecification
ModelLFP48-300-FSD
Battery Capacity15.36kWh
Battery Internal Resistance<10mΩ
Single Battery Capacity300Ah
Nominal Operating Voltage51.2V
Maximum Output Current210A
Standard Input Current150A (Max 210A)
Overpressure Protection58.4V
Overcharge Protection Recovery54.0V
Overdischarge Protection43.2V
Overdischarge Protection Recovery (within 30 seconds)48V (tunable)
Charging Over-Temperature Protection50℃
Charge Over-Temperature Protection Recovery45℃ (tunable)
Charging Low Temperature Protection0℃ (tunable)
Charge Cryoprotection Recovery5℃
Discharge Over-Temperature Protection50℃
Discharge Over-Temperature Protection Recovery45℃
Low Temperature Protection-15℃
Low Temperature Protection Recovery-10℃
Charging Overcurrent215A
Discharge Overcurrent Protection215A
Short Circuit ProtectionYes
Amount Of Electricity Shipped40% to 60%
EqualizationPassive equilibrium
Power Off Self-Consumption≤300uA
Battery Cycle Life (25°C, 70% SOH)≥8000 Cycles
Battery Cycle Life (45°C, 70% SOH)≥3000 Cycles
Communication ProtocolsRS232, RS485, CAN
Dimensions (LxWxH)453 x 260 x 879 mm
Weight110kg

11. Warranty and Support

DATOUBOSS provides a reliable warranty and dedicated customer support for your peace of mind.

DATOUBOSS LiFePO4 Battery with warranty text
Figure 11.1: Information regarding the reliable warranty and support.

11.1. Warranty

A 5-year guarantee covers non-human-caused defects. Please retain your proof of purchase for warranty claims.

11.2. Customer Support

For technical assistance, troubleshooting, or warranty inquiries, please contact DATOUBOSS customer support:

  • Whatsapp: +86 18900786512
  • Email: 3509534322@qq.com
  • WeChat: +8618900786512

Our team is committed to providing prompt professional support to ensure your worry-free use of the product.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.