ELECTESLA ES280, ES280A

Contents

ELECTESLA ES280/ES280A VFD Inverter User Manual

Model: ES280, ES280A Series Variable Frequency Drive

1. Introduction

Thank you for choosing the ELECTESLA ES280/ES280A series Variable Frequency Drive (VFD) Inverter. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VFD. The ES280/ES280A series is designed for precise motor speed control, offering power ratings from 0.75KW to 3KW, converting 1-phase 220V input to 3-phase 220V output, with an adjustable frequency range of 0-400Hz. It also features MPPT functionality for solar applications.

Two ELECTESLA ES280/ES280A VFD inverters, showing power ratings and features.
ELECTESLA ES280/ES280A VFD Inverters (0.75-3KW, 220V, 0-400Hz, MPPT)

2. Safety Information

WARNING: Electrical shock hazard. Only qualified personnel should perform installation and maintenance.

  • Always disconnect power before installation, wiring, or maintenance.
  • Ensure proper grounding of the VFD and motor.
  • Do not touch electrical components while power is applied.
  • Verify input voltage and motor specifications match the VFD's ratings.
  • Install the VFD in a clean, dry, and well-ventilated environment.
  • Protect the VFD from direct sunlight, moisture, and corrosive gases.

3. Product Features

The ELECTESLA ES280/ES280A VFD Inverter offers advanced features for reliable and efficient motor control:

Key Characteristics:

  • Digital Inputs: 5 (X1-X5)
  • Analog Inputs: 2 (AVI: 0-10V; ACI: 0-20mA)
  • Analog Output: 1 (AO: 0-10V)
  • Relay Output: 1
  • MPPT Function: Yes (Maximum Power Point Tracking)
Diagram showing ES280 VFD characteristics including digital and analog inputs/outputs, relay output, and MPPT function.
ES280 VFD Characteristics and Terminal Block Layout

Top Ten Functions:

  1. Instant Motor Protection
  2. Easy PLC Operation
  3. Seven Frequency Options
  4. RS485 Communication
  5. Intelligent Setting Parameters
  6. Multi-Speed Operation
  7. Automatic Energy Saving Control
  8. Automatic Voltage Regulation
  9. Wide Voltage Design
  10. Multiple Control Modes
Infographic listing the top ten functions of the VFD, such as motor protection, PLC operation, and RS485 communication.
Top Ten Functions of the ELECTESLA VFD

4. Specifications

General Specifications:

  • Type: DC/AC Inverters
  • Output Type: Triple
  • Output Frequency: 0-400Hz
  • Certification: CE
  • Customization: Yes

Model Naming Convention (Example: ES280-0R7G/1R5P-3):

Diagram explaining the ES280 model naming convention, including voltage degree, motor power, and power code.
ES280 Nameplate and Model Explanation
  • Company Model: ES280 or ES280A
  • Power Code: 0R7 (0.75KW), 1R5 (1.5KW)
  • Motor Power: G (Constant Torque), P (Constant Power)
  • Voltage Degree: 1 (1HP 220V), 2 (3HP 220V), 3 (3HP 380V)

Product Dimensions and Installation:

Product Dimensions and Installation Details
PowerPower SupplyOutput Current (A)Overall Dimension L*W*H (mm)Installation Dimension L*W - mounting screw
0.4KWSingle-phase AC 200V-240V 50Hz/60Hz2.1170*79*127160*60.5-M5
0.75KW3.8170*79*127160*60.5-M5
1.5KW7187*86*144173*68-M4
2.2KW9187*86*144173*68-M4
3.0KW13215*101*151204*83.5-M4
4.0KW15237*111*168216*88-M5
0.4KWThree-phase AC 200V-240V 50Hz/60Hz2.1170*79*127160*60.5-M5
0.75KW3.8170*79*127160*60.5-M5
1.5KW7187*86*144173*68-M4
2.2KW9187*86*144173*68-M4
3.0KW13215*101*151204*83.5-M4
4.0KW15237*111*168216*88-M5
0.4KWThree-phase AC 380V-440V 50Hz/60Hz1.5170*79*127160*60.5-M5
0.75KW2.1170*79*127160*60.5-M5
1.5KW3.8187*86*144173*68-M4
2.2KW5.1187*86*144173*68-M4
3.0KW7.1215*101*151204*83.5-M4
4.0KW9.0237*111*168216*88-M5
5.5KW12.6237*111*168216*88-M5
7.5KW16.1237*111*168216*88-M5
Diagram showing product dimensions (L, W, H) and installation dimensions for various power ratings.
Product Dimensions and Installation

5. Installation and Setup

5.1 Wiring Connections

Carefully connect the power supply and motor to the VFD's terminal blocks. Ensure all connections are secure and follow local electrical codes.

Close-up of the VFD terminal block for AC220 power input (L, N) and motor output (U, V, W), along with control terminals.
Terminal Block for AC220 Power and Motor Connections

Power Input (AC220): Connect the single-phase AC 220V power supply to the 'L' and 'N' terminals. For three-phase models, connect to 'R', 'S', 'T' (not explicitly shown for 3-phase 220V input in image, but implied by product variants).

Motor Output: Connect the three-phase motor to the 'U', 'V', and 'W' terminals.

Grounding: Connect the protective earth (PE) terminal to a reliable ground.

Control Terminals:

  • Digital Inputs (X1-X5): For external control signals.
  • Analog Inputs (AVI, ACI): AVI (0-10V) and ACI (0-20mA) for speed reference or other analog control.
  • Analog Output (AO1): 0-10V output for monitoring.
  • Relay Output (TA, TB, TC): For external control or status indication.
  • +10V, GND: Power supply for external potentiometers or sensors.
VFD front panel with digital display and terminal block for AC380 power input and motor output.
Terminal Block for AC380 Power and Motor Connections (for relevant models)

5.2 Removable Keypad

The VFD features an easy-operation removable keypad that can be connected via a ribbon cable for remote control or easier access.

ELECTESLA VFD with its detachable keypad connected via a ribbon cable, showing the back of the unit.
VFD with Removable Keypad
Play video
Watch video online

6. Operating Instructions

The VFD is equipped with a digital display and a user-friendly control panel for setting parameters and controlling motor operation.

6.1 Control Panel Overview

Panel Operation Instructions
ItemSymbolFunction
Digital tube display8.8.8.8.To display frequency or parameter etc using LED.
Parameter setting keyPRGUsed to read and modify each group of parameters, press to enter the parameter group or display the parameter value.
Enter keysENTERPress this key to enter the next level menu. Confirm setting parameters
Increment▲To increase parameter number or parameter set value
Decrement▼To reduce parameter number or parameter set value
RunRUNStart the VFD when using the operating panel control mode.
STOPSTOPStop the VFD when the drive is in the RUNNING status. Perform a reset operation when the drive is in the FAULT status.
Speed control knobTo adjust frequency
Multifunction keysDefault for VFD jog operation
Shift keysThe display parameters of operation/shutdown monitoring are cyclically switched; When setting data in programming state, you can change the modification bit of setting data
Table detailing the functions of each button and display element on the VFD control panel.
VFD Control Panel and Button Functions

6.2 Frequency Adjustment

The VFD allows for precise speed adjustment of your motor. The frequency can be adjusted from 0-400Hz using the speed control knob on the panel. This twist-and-set method makes operation simple and clear.

Image showing the VFD control panel with a focus on the speed control knob for 0-400Hz adjustment.
0-400Hz Adjustable Speed Control

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your ELECTESLA VFD Inverter.

  • Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Ventilation: Ensure the independent cooling fan and ventilation openings are not obstructed to prevent overheating.
  • Connections: Periodically check all electrical connections for tightness and signs of corrosion.
  • Environment: Maintain the operating environment within specified temperature and humidity ranges.
  • Inspection: Inspect the VFD for any visible damage or unusual noises during operation.

8. Troubleshooting

If you encounter issues with your VFD, refer to the following general troubleshooting steps. For specific error codes or complex problems, please contact technical support.

  • No Power: Check the main power supply, circuit breaker, and VFD input wiring.
  • Motor Not Running: Verify motor connections, VFD output settings, and ensure the RUN command is active.
  • Overheating: Check for proper ventilation, clean cooling fins, and ensure the ambient temperature is within limits.
  • Abnormal Noise: Inspect motor and VFD for loose connections or mechanical issues.
  • Display Errors: Note any error codes displayed on the digital panel and consult the full user manual (if available) or contact support.

9. Warranty and Support

9.1 Warranty

The ELECTESLA ES280/ES280A VFD Inverter comes with an 18-month warranty from the date of purchase, covering manufacturing defects.

9.2 Technical Support

For any technical assistance, user manual requests, or bulk order inquiries, please contact ELECTESLA support:

  • WhatsApp: +8615665610693
  • Email: max@jinqu-electric.com
  • Online Service: Refer to the seller's online service portal.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.