1. Introduction
The Hantek TO1000 series represents a new generation of multi-functional, full touch screen tablet oscilloscopes. Designed for portability and versatility, these devices feature a thin, lightweight body, making them easy to carry. The unique hanging design allows for hands-free operation, while its anti-falling and anti-seismic construction ensures durability. The TO1000 series integrates an oscilloscope, multimeter, signal generator, and spectrum analyzer into a single unit. Equipped with a super large capacity lithium battery, it offers long endurance and supports fast Type-C charging, providing abundant power for extended use.
2. Product Overview
The Hantek TO1000 series is a 3-in-1 device combining the functionalities of an oscilloscope, multimeter, and waveform generator. It features a full touch screen for intuitive operation and an all-English interface for global usability. The robust design includes four-corner protection, making it anti-fall and earthquake-resistant. The device supports data storage to a USB disk and offers various mathematical operations and FFT spectrum analysis.


3. Key Features
- Multi-touch large screen with 800*480 resolution, offering a user-friendly UI and good interaction experience.
- Standard configuration of 2 or 4-channel oscilloscope, with a maximum bandwidth of 250MHz, maximum sampling rate of 1GSa/s, and 8M large storage depth.
- High-precision multimeter with data recording, storage, trend chart, and statistical analysis functions.
- Built-in signal generator with a variety of arbitrary waveforms, supporting up to 25MHz output frequency.
- One-key waveform storage for convenient and fast data saving.
- Suspension foot design for multi-angle adjustment, anti-falling, and anti-seismic protection, allowing for versatile placement.
- Built-in super large capacity lithium battery for long endurance, with standby time up to half a year.
- Standard 18W Type-C charger supports fast charging and can be shared with mobile phones.
4. Package Contents
TO1252D Standard Configuration:
- Oscilloscope host x1
- Package x1
- Probe x1
- Crocodile clip test wire x2
- Multimeter Probe x1
- 18W Charger Type-C x1

TO1254D Standard Configuration:
- Oscilloscope host x1
- Package x1
- Probe x2
- Crocodile clip test wire x3
- Multimeter Probe x1
- 18W Charger Type-C x1

5. Specifications
General Specifications
- Model Numbers: TO1252D/TO1254D
- Brand Name: Hantek
- Certification: CE
- DIY Supplies: Electrical
- Origin: Mainland China
- Battery Included: Yes
- IS Battery Demountable: Yes
- High-concerned chemical: None
Oscilloscope Parameters
| Parameter | TO1252D | TO1254D |
|---|---|---|
| Channel | 2CH | 4CH |
| Bandwidth | 250MHz | 250MHz |
| Sampling rate | 1GSa/S | 1GSa/S |
| Storage depth | 8M | 8M |
| Signal source | 25MHz | 25MHz |
| Multimeter | ✓ | ✓ |



Multimeter Parameters

Arbitrary Wave Generator Parameters

Measuring Function Parameters

Trigger Sensitivity

6. Setup
- Unpacking: Carefully remove the oscilloscope and all accessories from the packaging. Verify that all items listed in the 'Package Contents' section are present and undamaged.
- Charging: Before first use, fully charge the device using the provided 18W Type-C charger. Connect the charger to the Type-C port on the side of the oscilloscope. The charging indicator will show the charging status.
- Power On/Off: Press and hold the power button to turn the device on or off.
- Probe Connection: Connect the oscilloscope probes to the BNC input channels (CH1, CH2, CH3, CH4) as required for your measurement. Ensure a secure connection.
- Multimeter Probe Connection: For multimeter functions, connect the multimeter probes to the dedicated V/Ω/C/+, COM, mA, and A ports on the side of the device.
- Plug Type: The device comes with either a US or EU plug type depending on your region.


7. Operating Instructions
7.1 User Interface and Navigation
The TO1000 series features a full touch screen for intuitive control, similar to a smartphone. The 7-inch large screen provides an intuitive display. The device operates with an all-English interface, making it easy for beginners to get started.

7.2 Oscilloscope Function
Access the oscilloscope function by tapping the 'OSC' icon on the home screen. You can configure parameters such as vertical scale, horizontal time base, trigger settings, and measurement types using the touch interface. The device supports 2 or 4 channels depending on the model (TO1252D for 2 channels, TO1254D for 4 channels).


7.3 Multimeter Function
The 4000-count multimeter can be used as an integrated multimeter with other functions, though not simultaneously. It provides AC and DC voltage, current, resistance, capacitance, diode, and on-off measurements. It also features data recording, storage, trend charts, and statistical analysis.

7.4 Signal Generator Function (AFG)
The signal generator can be used as an integrated oscilloscope and signal generator simultaneously. It features a built-in variety of arbitrary waveforms, supports AM/FM modulation, and offers switchable high and low resistance output. The maximum output frequency is up to 25MHz with 12-bit high resolution and 200MS/s sampling rate.
7.5 Data Storage
The device supports saving data to an 8G-U disk. You can save reference waveforms, waveform pictures, settings, and perform one-click screensaver to the U disk function.

7.6 Mathematical Operations and FFT Spectrum
Perform mathematical operations (addition, subtraction, multiplication, division) between source A and source B. The FFT (Fast Fourier Transform) function converts time domain data into the frequency domain, allowing for analysis of the signal's frequency components.
7.7 Triggering
The device offers 7 trigger types, making it easier to capture instantaneous and abnormal signals. These include Single, Automatic, Edge, Pulse, Video, Slope, and Timeout triggers.

7.8 X-Y Mode and ROLL Rolling Mode
The X-Y mode is used for Lissajous measurements to determine the phase difference between two sine-wave signals of the same frequency. The ROLL rolling mode displays waveforms from right to left, typically used for observing waveforms below 5Hz, providing real-time display without dead zones or data loss.


7.9 Computer Software
The oscilloscope can communicate with a computer via its USB interface. Measurement waveforms can be easily operated and analyzed using the dedicated computer software. The software is primarily used for editing output arbitrary waves for the TO1254D model.

7.10 Product Video Demonstration
Official product demonstration video showcasing features and usage.
8. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device.
- Storage: Store the oscilloscope in a cool, dry place away from direct sunlight and extreme temperatures. Use the provided package for protection during storage and transport.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. If storing for an extended period, charge the battery to approximately 50-70% and recharge every few months.
- Software Updates: Periodically check the Hantek official website for firmware and software updates to ensure optimal performance and access to new features.
9. Troubleshooting
- Device not powering on: Ensure the battery is sufficiently charged. Connect the Type-C charger and try again. If the issue persists, contact support.
- Screen unresponsive: Try restarting the device. If the touch screen remains unresponsive, ensure the screen is clean and free from debris.
- Inaccurate measurements: Verify that probes are correctly calibrated and connected. Check probe attenuation settings in the software. Ensure proper grounding for measurements.
- Software connection issues: Confirm USB cable connection to the computer. Ensure the correct drivers are installed. Refer to the Hantek website for the latest software and drivers.
- Waveform distortion: Check the sampling rate and storage depth settings. Ensure the input signal is within the device's specifications.
10. User Tips
- For complex waveform analysis, utilize the computer software for more detailed editing and analysis capabilities.
- Take advantage of the hanging design for hands-free operation in various work environments.
- Regularly back up important measurement data to the U disk to prevent loss.
- Explore the 42 kinds of measurement parameters and 7 trigger types to optimize your testing scenarios.
11. Warranty and Support
For detailed warranty information and technical support, please refer to the official Hantek website. The website also provides access to the latest software, firmware, and comprehensive user manuals.
- Hantek Official Website: https://hantek.com/
- TO1000 Series Product Information: https://hantek.com/products/detail/18191
- Tablet 1000 Software: https://hantek.com/Products/SoftwareDL?id=43621