1. Introduction
The LILYTECH ZL-7918C is an intelligent temperature and humidity controller designed for incubators and similar applications. It offers precise control over various parameters essential for successful incubation, including temperature, humidity, egg turning, ventilation, and lighting. This manual provides detailed instructions for the installation, operation, and maintenance of your ZL-7918C controller.

2. Specifications
The following table outlines the key technical specifications of the ZL-7918C controller:
| Feature | Description |
|---|---|
| Power Supply | 100 ~ 240Vac, 50/60Hz |
| Inputs | 1x Temperature Sensor (L=2.0m), 1x Humidity Sensor (L=2.0m), 1x Door Switch |
| Temperature Setting Range | 1 ~ 75°C (Fahrenheit and Celsius units) |
| Humidity Setting Range | 10 ~ 99%RH |
| Temperature Display Range | -9.9 ~ 99.9°C |
| Humidity Display Range | 0 ~ 99%RH |
| Temperature Measuring Accuracy | ±1% |
| Humidity Measuring Accuracy | ±3% |
| Outputs | 8 outputs: Main-Heater, Aux-Heater, Lamp, Humidity, Ventilation Fan, Right-Turning, Left-Turning, Exhaustion Fan |
| Output Load (Max) | Main-Heater ≤ 1500W, Aux-Heater ≤ 1500W, Lamp ≤ 100W, Others ≤ 1A/250Vac |
| Hatched Day Counter | Max 99 days |
| Egg Turn Control Period | 1 ~ 999 minutes |
| Egg Turn Driving Time | 0 ~ 999 seconds |
| Egg Turn Times Counter | 0 ~ 999 times |
| Air Exhaustion Control Period | 1 ~ 999 minutes |
| Air Exhausting Time | 0 ~ 999 seconds |
| Lamp Control Period | 1 ~ 999 minutes |
| Illuminating Time | 1 ~ 999 seconds |
| Operation Environment | -10 ~ 45°C, <90% RH (non-condensing) |
| Device Dimensions (L*W*H) | 160 * 80 * 95 mm |
| Installation Drilling Size | 151.5 * 76.5 mm |
| Type | Large-Sized Incubator Controller |
| Egg Turning Mode | Automatic Egg Turning |
| Usage | Bird, Chicken, Duck, Goose, Ostrich, Reptile, Turkey, Emu incubation |
| Hatching Rate | Up to 90% (dependent on external factors) |
| Voltage | 110-240Vac |
| Weight | 0.7 kg |
| Key Selling Points | High-accuracy |
| Applicable Industries | Farms |
3. Setup and Installation
3.1 Physical Installation
The ZL-7918C controller is designed for panel mounting. Ensure you have a cutout with dimensions of 151.5 mm x 76.5 mm for proper fit. Secure the controller using the provided mounting clips or screws.
3.2 Wiring Diagram
Carefully follow the wiring diagram below to connect the power supply, sensors, and output devices (heaters, fans, egg turn motors, lamp, humidifier). Incorrect wiring can damage the unit or connected equipment. Always ensure power is disconnected before performing any wiring.

Wiring Connections Overview:
- Terminals 1-4: Sensor connections. Red, Yellow, Black, Orange wires for Temperature and Humidity sensors.
- Terminals 5-8: Switch input (S1).
- Terminals 9-12: Not explicitly labeled in diagram, typically for auxiliary functions or unused.
- Terminals 13-14: AC-N (Neutral) and AC-L (Live) for 100-240Vac power supply.
- Terminals 15-16: HEAT1 (Main Heater, max 1500W).
- Terminals 17-18: HEAT2 (Auxiliary Heater, max 1500W).
- Terminals 19-20: HUMI (Humidifier, max 7.5A).
- Terminals 21-22: LAMP (Lamp, max 300W).
- Terminals 23-24: CIR. FAN (Circulation Fan, max 7.5A).
- Terminals 25-26: EXHAUST (Exhaust Fan, max 5A).
- Terminals 27-28: RIGHT (Right Egg Turning Motor, max 1.5A).
- Terminals 29-30: LEFT (Left Egg Turning Motor, max 1.5A).
- PE: Protective Earth connection.
Ensure all connections are secure and insulated. Verify correct voltage and current ratings for all connected devices to prevent damage.
4. Operating Instructions
4.1 Display Overview

- PV (Process Value) TEMP: Displays the current measured temperature.
- PV (Process Value) WET%: Displays the current measured humidity.
- SV (Set Value) TEMP: Displays the set temperature.
- SV (Set Value) WET%: Displays the set humidity.
- Indicators: FAN, HEAT1, HEAT2, UP, LAMP, DOWN, WET, ALARM indicate active functions or states.
- Buttons: SET, UP arrow, DOWN arrow, ENTER.
4.2 Basic Operation
- Power On: After correct wiring, apply power to the controller. The display will light up, showing current temperature and humidity.
- Setting Temperature/Humidity:
- Press the SET button once to enter temperature setting mode. The SV TEMP value will flash.
- Use the UP and DOWN arrow buttons to adjust the desired temperature.
- Press ENTER to confirm and save the setting, or SET again to cycle to humidity setting.
- Repeat for humidity setting (SV WET%).
- Press ENTER to save and exit setting mode.
- Egg Turning Control: The controller automatically manages egg turning based on programmed period and driving time. These parameters can be adjusted in the advanced settings menu (refer to the full manual for detailed menu navigation).
- Ventilation and Exhaustion: The ventilation fan and exhaustion fan operate based on programmed periods and times to ensure proper air exchange. These settings are also configurable in the advanced menu.
- Lamp Control: The lamp can be set to illuminate for specific periods and durations, useful for observation.
- Hatched Day Counter: The controller tracks the number of days since incubation started, up to 99 days.
4.3 Advanced Settings
The ZL-7918C has an advanced menu for configuring parameters such as egg turning period/duration, air exhaustion period/duration, lamp period/duration, temperature/humidity calibration, and alarm thresholds. Accessing and adjusting these settings typically involves pressing and holding the SET button for several seconds to enter the parameter menu. Consult the comprehensive user manual for a complete list of parameters and their adjustment procedures.
5. Maintenance
- Cleaning: Keep the controller's display and buttons clean using a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Sensor Care: Ensure temperature and humidity sensors are kept clean and free from debris. Avoid physical damage to the sensor probes.
- Environmental Conditions: Operate the controller within the specified environmental conditions (-10 ~ 45°C, <90% RH non-condensing) to ensure longevity and accurate performance.
- Connections: Periodically check all wiring connections to ensure they are secure and free from corrosion.
6. Troubleshooting
If you encounter issues with your ZL-7918C controller, consider the following common troubleshooting steps:
- No Power/Display Off:
- Check the main power supply to the controller.
- Verify AC-L and AC-N wiring connections (Terminals 13-14).
- Ensure the power source is within the 100-240Vac range.
- Incorrect Temperature/Humidity Readings:
- Check if the temperature and humidity sensors are correctly connected to terminals 1-4.
- Ensure sensors are not damaged or obstructed.
- Verify sensor placement within the incubator for accurate readings.
- Consider calibrating the sensors through the advanced settings if readings are consistently off.
- Heater/Fan/Motor Not Activating:
- Check the wiring for the specific output device (e.g., HEAT1, HUMI, CIR. FAN).
- Ensure the set temperature/humidity is outside the current measured value to trigger the output.
- Verify the output device itself is functional (e.g., heater element, fan motor).
- Check the load capacity of the output; exceeding max wattage/amperage can prevent operation.
- Egg Turning Malfunction:
- Verify connections to RIGHT and LEFT egg turning motor terminals.
- Check the egg turning period and driving time settings in the controller.
- Ensure the egg turning motor is functional.
- Alarm Triggering Frequently:
- Review the alarm threshold settings in the advanced menu.
- Check for stable temperature and humidity conditions within the incubator.
- Ensure sensors are providing accurate readings.
For persistent issues, refer to the full product manual or contact LILYTECH customer support.
7. User Tips
- Sensor Placement: Position temperature and humidity sensors away from direct heat sources or water to get the most accurate readings of the general incubator environment.
- Initial Calibration: It is recommended to verify the accuracy of the temperature and humidity sensors against a known good reference thermometer/hygrometer upon initial setup. Adjust calibration settings if necessary.
- Stable Environment: For optimal performance, ensure the incubator is placed in a stable environment, free from significant temperature fluctuations or drafts.
- Regular Monitoring: Even with automatic control, regularly monitor the incubator's conditions and the controller's display to ensure everything is operating as expected.
- Power Outage Recovery: Familiarize yourself with how the controller behaves after a power outage, especially regarding saved settings.
8. Warranty and Support
The LILYTECH ZL-7918C Incubator Controller comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Contact information can typically be found on the product packaging or the official LILYTECH website.