JIKONG JK-BD4A24S-4P

Contents

JIKONG JK-BD4A24S-4P Smart Active Balance BMS Instruction Manual

Model: JK-BD4A24S-4P

Brand: JIKONG

1. Introduction

The JIKONG JK-BD4A24S-4P Smart Active Balance Battery Management System (BMS) is designed for large capacity series lithium battery packs. It integrates advanced features such as voltage acquisition, high-current active balancing, and comprehensive protection mechanisms including overcharge, over-discharge, overcurrent, and over-temperature protection. The BMS also includes a coulomb meter, Bluetooth communication, and optional GPS remote functions.

This BMS is compatible with various battery chemistries, including Lithium Iron Phosphate (Lifepo4), Ternary Lithium, and Lithium Titanate (LTO) battery types. It is suitable for a wide range of applications, enhancing battery consistency, extending range, and delaying battery aging.

Application scenarios for JIKONG BMS
Figure 1: Wide range of application scenarios including E-bikes, electric tricycles, forklifts, industrial drones, scooters, and RV energy storage.

2. Functional Characteristics

The JIKONG JK-BD4A24S-4P BMS offers a rich set of features to ensure optimal battery performance and safety:

  • LED Bluetooth status indicator
  • APP Bluetooth remote operation
  • Battery capacity calculation
  • High precision voltage acquisition (±3mV)
  • High precision current acquisition
  • Support information screen display
  • Accurate time logging
  • Support RS485 (Optional)
  • Support CAN (Optional)
  • Support parallel function (Optional)
  • Support alarm function (Optional)
  • Support heating function (Optional)
  • Support GPS communication
  • Charge overcurrent protection
  • Charge overvoltage protection
  • Charge over temperature protection
  • Low temperature protection during charge
  • Discharge overcurrent protection
  • Discharge undervoltage protection
  • Discharge over temperature protection
  • Short circuit protection

2.1. Active Balancing (Lossless Balancing)

Active Balancing is achieved through energy transfer, moving energy from cells with higher energy to cells with lower energy, thereby achieving voltage balance with minimal energy loss. The JIKONG SMART BMS management system is tailored for large capacity series connected lithium battery packs, with voltage acquisition, active current, and the ability to achieve a continuous balanced current of 0.4A-2A. This high current active balancing technology maximizes battery consistency, improves battery range, and delays battery aging.

Diagram illustrating active balancing process in battery cells
Figure 2: Active balancing mechanism ensuring uniform cell voltage.

2.2. Rich Interface Options

The BMS provides multiple communication and control interfaces to meet diverse daily needs:

  • CAN: For Controller Area Network communication.
  • RS485: For serial communication, often used in industrial applications.
  • BT (Bluetooth): For wireless connection to the mobile APP.
  • NTC: For Negative Temperature Coefficient thermistor input, enabling temperature monitoring.
  • Soft Switch: For flexible power control.
  • SOC Indicator: State of Charge indicator.
  • Key Switch: For physical power control.
  • Active Equalizer: Integrated active balancing functionality.
Icons representing various interfaces on the JIKONG BMS
Figure 3: Overview of communication and control interfaces.

2.3. JIKONG BMS Communication via APP

The mobile phone Bluetooth APP allows for comprehensive monitoring and control of the BMS. Users can:

  • Modify PVD (Protection Value Definition)
  • Charge ON/OFF
  • Discharge ON/OFF
  • Balance ON/OFF
  • Emergency ON/OFF
  • Display Always On ON/OFF
  • Smart Sleep On ON/OFF
  • Timed Stored Data ON/OFF
  • Disable Temp. Sensor ON/OFF
Screenshots of the JIKONG BMS mobile application
Figure 4: Mobile APP interface for monitoring and control.

3. Package Contents

Please verify that all items are present and in good condition upon opening the package:

  • BMS unit (x1)
  • NTC temperature sensor (400mm) (x1)
  • Balance Wires (750mm) (x1)
  • Switch (500mm) (x1)
  • Packing box (x1)
Diagram showing the contents of the JIKONG BMS package
Figure 5: Package contents of the JIKONG BMS.

4. Specifications

4.1. Main Parameters

ParameterValueUnit
Supply voltage20-100V
Operating power consumption<800mW
Operating temperature-30-70°C
Maximum number of collection strings24String
Maximum balancing current0.4A
Maximum charging current40A
Maximum discharge current40A
Maximum instantaneous current80A
Maximum internal loop resistance2.8mΩ
Finished weight205g

4.2. Dimensions

The JIKONG JK-BD4A24S-4P series protection board has dimensions of 116mm × 103mm × 17.6mm.

Dimensional drawing of the JIKONG JK-BD4A24S-4P BMS
Figure 6: Product dimensions (116mm x 103mm x 17.6mm).

4.3. Material

The casing is made of fully aluminum alloy and adopts one-piece molding technology, providing superior heat dissipation with a high thermal conductivity of <300[W/(m·K)]. The aluminum shell adopts graphite thermal conductivity material to maximize heat dissipation, and the surface is sprayed with a layer of graphite material for more uniform and balanced heat transfer.

5. Setup and Installation

5.1. Pre-installation Checks

Before powering on the protection board, ensure the following:

  • Verify that the balance cable is properly connected.
  • Confirm that the P- and B- connections are correct.
  • Ensure the protection board is securely fixed to the battery pack.

Failure to perform these checks may lead to abnormal operation or damage to the device.

5.2. Wiring Diagram

The JIKONG JK-BD4A24S-4P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Refer to the diagram below for proper connection.

Wiring diagram for JIKONG JK-BD4A24S-4P BMS for a 24S configuration
Figure 7: Wiring diagram for JK-BD4A24S-4P-24S. Connect the load and charger as shown, ensuring correct polarity for P- and B- terminals. The balance wires connect to the battery cells from B- to B24. Temperature probes and heating elements are connected as indicated.

5.3. Interface Definitions

The BMS features various connectors for different functions:

  • P1 (HY2.0-15P) - Balance with Acquisition Interface: Connects to the balance wires for individual cell voltage monitoring (B-, B1 to B14).
  • P2 (HY2.0-11P) - Balance with Acquisition Interface: Continues cell voltage monitoring (B15 to B21).
  • P3 (HY2.0-4P) - Temperature Interface: For connecting temperature sensors (T1A, T1B, T2A, T2B).
  • P4 (HY2.0-4P) - Optional External Temperature Interface: For additional temperature sensors (T3A, T3B, T4A, T4B).
  • P5 (1.25T-4PWT) - GPS Interface: For connecting GPS modules (VGPS, TX, RX, GND).
  • P6 (A1254WF-2A) - Buzzer Interface (Optional): For connecting an alarm buzzer (VCC, GND).
  • P7 (A1254WF-4A) - Communication Interface (Optional): For RS485 communication (RS485 B, RS485 A).
  • P8 (A1254WF-6A) - Display Interface: For connecting external display screens (VCC, A, B, GND, K+, K-).
  • P9 (A1254WF-3A) - Parallel Interface (Optional): For parallel module enable signal and status (GND, P-EN, P-status).
  • Heating Wire: 16AWG orange-yellow wire for connecting the heater element (HT-).
  • D1: Bluetooth connection indicator (steady on when connected, blinking when disconnected).
  • P-: Connects to external load or negative terminal of charger.
  • B-: Connects to the negative battery terminal.

6. APP Operation Instructions

6.1. APP Installation

The mobile APP matching the product can be obtained by scanning the QR code below. An Android version 7 minimum is required for the Android APP.

QR code for JIKONG BMS mobile APP download
Figure 8: Mobile APP link QR code.

6.2. Device Activation

The protection board does not have a physical power-on control switch. It is designed for a charging activation mode. After the battery assembly is complete, connect the charger (charger voltage 2V higher than battery voltage) to activate the BMS.

Alternatively, the BMS supports key activation and display activation. If you have an optional display screen and button, insert the cable into the display interface and press the button to activate.

6.3. Parameter Settings

Detailed parameter settings are performed within the mobile APP. Refer to the APP's interface for specific instructions on configuring parameters such as balance trigger pressure, protection thresholds, and communication protocols.

7. Operating Instructions

7.1. Active Equalization

The active equalization function transfers energy from higher voltage cells to lower voltage cells. Before using, set the battery type and basic parameters (number of cells, capacity, trigger equalization differential pressure, voltage/current calibration) in the APP. The default balance current is 0.4A. You can adjust this current based on your battery capacity (recommended not to exceed 0.2C). The balance function automatically activates when the cell voltage difference exceeds the set value and deactivates when it falls below the threshold. This function can be enabled or disabled via the BMS control page in the APP.7.2. GPS and Display Interface

The BMS includes reserved ports for optional GPS modules for battery location tracking and external display screens for viewing battery information. These can be selected and configured based on user needs.7.3. Heating Function (Optional)

If equipped, the heating function uses a resistance heater or heating film to warm the battery at low temperatures, preventing reduced activity. The designed heating current is 10A. Control this function via the APP's BMS control page. It is recommended to install a normally closed temperature control switch (45°C to 65°C) in series with the heating circuit as a secondary safety measure.7.4. Alarm Function (Optional)

The BMS supports an optional alarm function that provides external alerts when security risks such as over-temperature, overcharge, or over-discharge are detected.7.5. Battery Parallel Function (Optional)

For energy storage battery packs, the BMS supports a parallel function. This requires compatible parallel modules and disabling the 'charging current limiting' function in the APP.7.6. Protection and Recovery Functions

The BMS includes standard protection features with configurable parameters in the APP:

  • Charge Overvoltage Protection & Recovery: Protects against overcharging individual cells. Charging is cut off if any cell voltage exceeds the set overcharge protection voltage and resumes when all cells are below the recovery voltage.
  • Discharge Undervoltage Protection & Recovery: Prevents over-discharging. Discharge is cut off if any cell voltage drops below the set undervoltage protection voltage and resumes when all cells are above the recovery voltage. An automatic shutdown voltage is also configurable.
  • Charge Overcurrent Protection & Recovery: Protects against excessive charging current. Charging is cut off after a set delay if the current exceeds the continuous charging current and resumes after a set recovery time.
  • Discharge Overcurrent Protection & Recovery: Protects against excessive discharging current. Discharge is cut off after a set delay if the current exceeds the continuous discharge current (max 40A) and resumes after a set recovery time.
  • Over-temperature Protection & Recovery: Protects against high temperatures during charge and discharge. Charging/discharging is cut off if the temperature exceeds the set threshold and resumes when it falls below the recovery temperature.
  • Low-temperature Protection & Recovery: Protects against low temperatures during charge. Charging is cut off if the temperature falls below the set threshold and resumes when it rises above the recovery temperature. For extremely cold areas, the heating function is recommended.
  • Short Circuit Protection & Recovery: Standard feature that triggers if a short circuit is detected. Users can set the protection delay (in µs) and recovery time (in seconds) in the APP.

7.7. Emergency Switch

The emergency switch function allows the BMS to override protection mechanisms for 30 minutes in critical situations (e.g., over-temperature, over-discharge, overcharge, cell drop). This provides a temporary operational window, even if cell voltage reaches automatic shutdown levels, to prevent immediate system failure.7.8. Intelligent Sleep

The intelligent sleep function reduces the BMS's self-consumption. If the charging and discharging current is less than 1A for 26 consecutive hours, the BMS will enter sleep mode. It can be reactivated by pressing a button (if equipped) or by connecting a charger.7.9. Communication Function (Optional)

The BMS supports optional CAN and RS485 communication. Users can select the desired communication mode via the APP's BMS control page and configure the address and communication protocol according to their specific requirements. Refer to the Jikong Protection Board communication protocol document for details.

8. Troubleshooting

This section provides guidance for common issues you might encounter:

  • BMS not activating: Ensure all balance cables are correctly connected, P- and B- terminals are properly wired, and the board is securely fixed. Activate by connecting a charger or pressing the activation button (if available).
  • Charging/Discharging stops unexpectedly: Check the APP for active protection triggers (e.g., overvoltage, undervoltage, overcurrent, over-temperature, low-temperature). Address the underlying cause (e.g., reduce load, check charger output, allow battery to cool/warm).
  • Short circuit protection triggers: If this occurs upon initial connection of a charger or load, verify all external wiring for actual short circuits. If no physical short is present, consider increasing the short circuit protection delay time in the APP, as instantaneous peak currents from the charger or load capacitance might be triggering it.
  • Balancing not working: Ensure active balancing is enabled in the APP and that the balance trigger differential pressure is set appropriately. Check if the balance current is suitable for your battery capacity.

9. User Tips

  • Always double-check all wiring connections, especially balance cables and main power terminals (P- and B-), before applying power to the BMS to prevent damage.
  • For optimal performance and longevity, ensure the BMS is installed in an environment within its specified operating temperature range (-30°C to 70°C).
  • Regularly monitor battery parameters via the mobile APP to proactively identify and address potential issues.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.

11. Additional Resources

A detailed user manual in PDF format is available for download: User manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.