SONGGER CK-ASW-1-K

Contents

Ultrasonic Flow Meter CK-ASW-1-K

Instruction Manual

Model: CK-ASW-1-K | Brand: SONGGER

1. Product Overview

The SONGGER CK-ASW-1-K is a card-type ultrasonic flow meter designed for accurate measurement of liquid flow in closed pipelines. It is suitable for water, seawater, and wastewater applications, and can be customized for compatible corrosive liquids. The device adopts dual-channel ultrasonic measurement technology to ensure stable performance, long-term accuracy, and minimal maintenance. It is ideal for agricultural irrigation, water resource management, and industrial process monitoring, supporting bi-directional flow measurement and remote data communication.

SONGGER Ultrasonic Flow Meter, lightweight and precise battery-powered
Figure 1.1: SONGGER Ultrasonic Flow Meter - Lightweight and precise battery-powered design.
SONGGER Ultrasonic Flow Meter with key features: DN50 to DN150, RS485 Output, 2% Accuracy, Lithium Battery, DC8-24V
Figure 1.2: Key features of the CK-ASW-1-K Ultrasonic Flow Meter.

For a comprehensive guide, please refer to the official user manual PDF: View User Manual (PDF)

2. Product Features

  • Dual-Channel Ultrasonic Measurement: Ensures long-term accuracy and stability in various fluid conditions.
  • Battery Powered: Equipped with a built-in 3.6V 4Ah lithium battery with an approximate 15-year lifespan under standard conditions, with an option for external DC8–24V power supply.
  • IP68 Waterproof Design: Robust waterproofing makes it suitable for harsh environments.
  • High-Definition LCD Display: Shows 9-digit cumulative flow, 6-digit instantaneous flow, multiple unit options, and various status indicators.
  • No Moving Parts: Suitable for various water qualities, including those with sand and debris.
  • Ultra-thin Body: Saves installation space; made with special materials for high strength and corrosion resistance.
  • Bidirectional Measurement: Capable of measuring both forward and reverse instantaneous and cumulative flow rates.
  • Wide Pipe Compatibility: Suitable for pipes from DN15 to DN150, including steel, stainless steel, aluminum, and PVC.
  • Communication Interfaces: Standard RS485, USART, Infrared. Optional M-BUS and NB-IoT wireless transmission for remote monitoring.
Diagram showing features: Ultra-low power consumption with 10 years battery life, made original chip for enhanced precision, 13-month warranty, ample stock.
Figure 2.1: Core features of the Ultrasonic Flow Meter.
Images showing compatibility with carbon steel pipes, aluminum pipes, stainless steel pipes, and PVC pipes.
Figure 2.2: Compatibility with various pipe materials.
Diagram highlighting RS485 communication, battery power, and ultrasonic measurement technology.
Figure 2.3: Key technologies: RS485 Communication, Battery Powered, Ultrasonic Measurement.

3. Specifications

Table 3.1: Technical Specifications
AttributeValue
Pipe Size RangeDN50 to DN150 (with RS485, NB wireless module)
CommunicationRS485, customizable NB wireless
MaterialNylon + Fiberglass for tube, PEEK sensor, UV-resistant ABS housing
Installation MethodFlange Clamp
Accuracy±2%
Standard ComplianceIS04064-2014, GBT778-2018
Measured FluidWater, Sewage, Seawater (customizable for other liquids)
Fluid Temperature0.1-30°C
Environment Temperature-30-45°C; Humidity 100% (RH)
Pressure Resistance1.6 MPa
Pressure LossNone
Flow Field SensitivityU5 (Upstream), D3 (Downstream)
Climate & Mechanical ClassC
Electromagnetic ClassE2
Communication InterfaceRS485/USART/Infrared, Optional M-BUS; NB-IoT wireless transmission
Output SignalOptional OCT
Power SupplyBuilt-in Lithium Battery (3.6V, 4Ah) / External DC8-24V
Protection RatingIP68
DisplayDual-line local display showing 9-digit cumulative flow, 6-digit instantaneous flow, and various status indicators and units
Data StorageFerroelectric memory stores parameters, automatically recording cumulative flow for the past 32 months and 31 days
Measurement FrequencyStandard: 1/sec (adjustable), Calibration: 4/sec
Power Consumption<30uA, Battery lasts up to 15 years
Material CompositionNylon + Fiberglass for tube, PEEK sensor, UV-resistant ABS
Detailed specifications for DN50 model including IP68, RS485/Modbus, temperature, pressure, accuracy, materials, flange dimensions, and flow range.
Figure 3.1: Example specifications for DN50 model.
Product size diagram with dimensions W1, W2, H1, H2, D, D1, D2, and thickness 50.80.
Figure 3.2: Product dimensions.

4. Installation

4.1 Preparation

  • Ensure that the selected meter diameter (DN50 to DN150) matches the pipeline size and expected flow range.
  • Verify that the pipeline is fully filled with liquid and free of excessive air bubbles.
  • Confirm correct installation direction according to the flow arrow marked on the housing.

4.2 Installation Steps

  1. Install the meter using the flange clamp connection.
  2. Tighten bolts evenly to ensure proper sealing.
  3. Connect RS485 or other communication interfaces if remote monitoring is required.
  4. Power the device using the built-in battery or external DC supply as specified.
Diagram of the ultrasonic flow meter showing its components: protective cover, display screen and operation keypad, flow direction and diameter label, independent transducer, and waterproof junction box with RS485 and optional 4G wireless transmission.
Figure 4.1: Meter components and communication options.
Diagram illustrating communication options: RS485 for PLC and upper computer, and 4G wireless for phone or computer data access.
Figure 4.2: Communication setup for data monitoring.

5. Operation

5.1 Data Reading

Observe the LCD display for cumulative flow and instantaneous flow values. The dual-line display shows a 9-digit cumulative flow and a 6-digit instantaneous flow, along with various status indicators and units.

High-definition large display showing 9-digit cumulative flow, 6-digit instantaneous flow, multi-status indicators, and units. LCD content description includes icons for recoverable fault, leak detection, wireless communication, communication in progress, permanent fault, and low battery warning.
Figure 5.1: High-definition LCD display and indicators.

5.2 Remote Data Acquisition

Use the communication interface (RS485, USART, Infrared, or optional NB-IoT/M-BUS) for remote data acquisition if applicable. Refer to system configuration settings for baud rate and communication protocol details.

Video 5.1: Overview of the manufacturing process and product applications.

6. Maintenance & Storage

6.1 Maintenance

  • Clean the exterior surface with a soft damp cloth. Do not use corrosive cleaning agents.
  • The device is designed for minimal maintenance due to its no-moving-parts design.

6.2 Storage

  • Store the product in a dry and ventilated environment away from direct sunlight.
  • Avoid mechanical shock during transportation and storage.
  • If stored for an extended period, ensure environmental conditions remain within specified limits.

7. Safety & Warnings

7.1 General Warnings

  • This device operates in pressurized pipeline systems. Ensure the pipeline is depressurized before installation or removal.
  • Improper installation may result in leakage or measurement errors. Installation should be performed by qualified personnel.
  • Avoid strong electromagnetic interference near the installation site.
  • Do not disassemble the housing, as this may compromise the IP68 protection rating.
  • Installation must comply with local pipeline and electrical regulations.

7.2 Battery Safety

  • Risk of battery explosion if replaced with an incorrect type.
  • For battery-powered versions, do not short-circuit, recharge, or expose the lithium battery to high temperatures.
  • Dispose of used batteries according to local regulations.
  • Keep out of reach of children.

7.3 Disposal

  • Proper disposal: Follow WEEE directives for electronic waste.

8. Troubleshooting

  • Inaccurate Readings: Ensure the pipeline is completely filled with liquid and free of air bubbles. Verify the meter diameter matches the pipeline. Check for strong electromagnetic interference nearby.
  • No Display/Power: Check battery level or external power supply connection. If battery-powered, ensure the battery is correctly installed and not depleted.
  • Communication Issues: Verify RS485 wiring, baud rate, and communication protocol settings. For wireless modules, check signal strength and module configuration.
  • Leakage: Re-check flange clamp installation and bolt tightening to ensure proper sealing. If leakage persists, professional assistance may be required.
  • Error Indicators: Refer to the LCD display (Figure 5.1) for specific fault indicators (recoverable fault, permanent fault, low battery) and consult the full PDF manual for detailed error codes and solutions.

9. User Tips

  • Quick Installation: The card-type design allows for quick installation around the pipe without cutting or stopping flow, making it convenient for retrofitting.
  • Seamless Integration: The RS485 output integrates smoothly with existing monitoring systems and SCADA platforms via Modbus RTU.
  • Reliable Performance: Expect stable readings with 2% accuracy and minimal pressure drop, even in challenging environments.
  • Long-Term Use: The built-in lithium battery enables long-term standalone operation, ideal for energy monitoring systems and remote sites.
  • Versatile Application: Suitable for a wide range of pipe sizes (DN50 to DN150) and various pipe materials, including steel, stainless steel, aluminum, and PVC.
  • Liquid Compatibility: While designed for water, sewage, and seawater, customization options are available for other liquid types. Contact support for details.

10. Warranty & Support

10.1 Warranty

This product comes with a 13-month warranty, ensuring quality and reliability.

10.2 Technical Support

For technical consultations, bulk orders, or customization inquiries, please contact us:

Contact information including WhatsApp number +86 13311678550 and Email address miaazhao008@gmali.com
Figure 10.1: Contact Information for support.
  • WhatsApp: +86 13311678550
  • Email: miaazhao008@gmali.com

© 2024 SONGGER. All rights reserved.