1. Introduction
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your SKE 10.2KW Hybrid Solar System, model PH21-10.2K. Please read this manual thoroughly before installation and use to ensure optimal performance, safety, and longevity of your solar inverter system. This hybrid solar inverter is designed for off-grid single-phase applications, featuring a 48VDC input and 230VAC output, integrated with a 150A MPPT charge controller.
2. Setup and Installation
2.1 Safety Precautions
- Ensure all power sources are disconnected before installation or maintenance.
- Only qualified personnel should perform installation and wiring.
- Wear appropriate personal protective equipment (PPE).
- Verify correct polarity for all DC connections (solar panels, battery).
- Ensure proper grounding of the inverter.
2.2 Product Overview and Connections
Familiarize yourself with the inverter's components and connection points:

Figure 1: SKE Hybrid Solar Inverter Component Layout
- LCD display
- Function buttons
- Antenna
- RS-232/RS485 communication port
- Power on/off switch
- AC input (Ground/L/N)
- AC output (Main out for critical load, supports battery backup discharge)
- AC output (Bypass from AC input for non-critical loads, excess solar energy will be fed back to this output)
- PV1+ input
- PV1- input
- PV2+ input
- PV2- input
- Battery + Terminal
- Battery - Terminal
2.3 System Connection Diagram
The following diagram illustrates a typical system connection for the SKE Hybrid Solar Inverter, integrating solar panels, grid power, battery storage, and various application loads:

Figure 2: Inverter System Connection Overview
- Solar Panels: Connect solar panels to the PV1 and PV2 inputs of the inverter. Ensure the total PV array power and open circuit voltage are within the inverter's specifications.
- Grid/AC Input: Connect the utility grid or an AC generator to the AC input terminals.
- Battery: Connect the 48VDC battery bank to the Battery + and Battery - terminals.
- AC Output: Connect critical loads to the 'Main Out' AC output and non-critical loads to the 'Home Out' AC output (Bypass).
2.4 Initial Power-Up
After all connections are securely made and verified:
- Ensure the battery bank is properly charged.
- Turn on the battery breaker (if applicable).
- Turn on the solar array breaker (if applicable).
- Turn on the AC input breaker (if applicable).
- Finally, turn on the inverter's power on/off switch (5).
- Observe the LCD display for system status and any error messages.
3. Operating Instructions
3.1 LCD Display and Function Buttons
The LCD display (1) provides real-time system information, including input/output voltage, current, power, battery status, and operational mode. Use the function buttons (2) to navigate through menus, view different parameters, and configure settings.
3.2 Key Features and Operation Modes
The SKE PH21-10.2K inverter offers several configurable features:

Figure 3: Key Features of the SKE Hybrid Solar Inverter
- Built-in MPPT Solar Charge Controller: The 150A MPPT controller optimizes solar power harvesting.
- Wide PV Input Voltage Range: Supports a PV input voltage range of 60-500VDC.
- Selectable AC/Solar Input Charging Current: Allows customization of charging current based on available power sources.
- Configurable with Mains Voltage or Generator Power: Adaptable to various AC input sources.
- Working with or without Battery: The system can operate with or without a connected battery bank.
- Dual Communication Ports: Includes ports for battery communication and optional WiFi connectivity (for iOS and Android monitoring).
- High Frequency, High Efficiency: Operates at over 94% efficiency.
3.3 Monitoring
The optional WiFi module allows remote monitoring of your system's performance via a dedicated application on iOS and Android devices. Connect the antenna (3) for wireless communication.
4. Maintenance
4.1 General Cleaning
- Keep the inverter's exterior clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Ensure ventilation openings are not blocked to prevent overheating.
4.2 Anti-Dust Kit
The PH21-10.2K inverter includes a built-in anti-dust kit, designed to protect internal components in harsh environments. Regular inspection of the anti-dust filter (if accessible) and cleaning can help maintain optimal performance.

Figure 4: Inverter Protection Features
4.3 Periodic Inspection
- Periodically check all electrical connections for tightness and signs of corrosion.
- Inspect cables for any damage or wear.
- Monitor the inverter's performance via the LCD or monitoring app for any unusual readings.
5. Troubleshooting
The SKE PH21-10.2K inverter is equipped with multiple protection features to ensure safe operation. If the inverter encounters an issue, it may display an error code or shut down. Common protection features include:
- Overload Protection
- Over Temperature Protection
- Voltage Protection (Over/Under Voltage)
- Short Circuit Protection
- Overcurrent Protection
If your system is not operating as expected:
- Check Connections: Ensure all solar panel, battery, grid, and load connections are secure and correctly wired.
- Verify Power Sources: Confirm that solar panels are receiving adequate sunlight, the battery is charged, and the grid/generator is supplying power (if applicable).
- Review LCD Display: Check for any error codes or warning messages on the LCD display. Refer to the full product manual (if available) for specific error code interpretations.
- Reset Inverter: Try turning off the inverter using the power switch (5), waiting a few minutes, and then turning it back on.
- Consult Specifications: Ensure all connected components (solar panels, battery, loads) are within the inverter's specified operating limits.
If the problem persists after performing these checks, please contact customer support for assistance.
6. Specifications
Below are the detailed technical specifications for the SKE PH21-10.2K Hybrid Solar Inverter:

Figure 5: SKE PH21 Series Inverter Specifications
| Feature | Specification (PH21-10.2K) |
|---|---|
| Rated Power | 10200VA / 10200W |
| Peak Power | 20400W |
| Waveform | Pure Sine Wave |
| Inverter Output AC Voltage | (220Vac-240Vac)±5% |
| Inverter Efficiency | 94% |
| Transfer Time | 10ms (Personal Computer) / 20ms (Home Appliances) |
| No Load Power Consumption | <75W@48VDC |
| AC Input Voltage | 230VAC |
| Selectable Voltage Range | 170-280VAC (UPS) / 90-280VAC (APL) |
| Frequency Range | 50Hz/60Hz (Auto sensing) |
| Battery Voltage | 48VDC |
| Floating Charging Voltage | 54VDC |
| Overcharge Protection Voltage | 58.4VDC |
| Solar Charger Type | MPPT |
| MPPT Max PV Array Power | 10500W |
| MPPT Output Voltage Range | 60-450VDC |
| Max PV Array Open Circuit Voltage | 500VDC |
| Max Solar Charge Current | 150A |
| Max AC Charge Current | 120A |
| Max Charge Current | 150A |
| Machine Size (W*H*D) | 390*138*500mm |
| Package Size (W*H*D) | 620*492*263mm |
| Net Weight | 18kg |
| Gross Weight | 19kg |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Operating Temperature | 0°C - 55°C |
| Storage Temperature | -15°C - 60°C |
| Communication Interface | USB/RS232 |
7. Warranty and Support
7.1 Product Warranty
The SKE PH21-10.2K Hybrid Solar Inverter comes with a 2-year warranty from the date of delivery. During the warranty period, if the machine experiences a quality-related problem, please contact our sales staff. We will be responsible for customer service and provide necessary parts for free.
7.2 Post-Warranty Support
Even after the warranty period, or in cases of improper operation and man-made damage, we will still provide assistance and support. Spare parts will be provided at a cost price.
7.3 Contact Information
For technical support, warranty claims, or any inquiries regarding your SKE Hybrid Solar System, please contact us:
- WhatsApp: +86 15200511778
- Email: 19892006052@163.com
8. User Tips
- Optimize Solar Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to maximize energy harvest.
- Battery Management: For systems with batteries, monitor battery health and charge cycles to prolong their lifespan. Avoid deep discharges where possible.
- Regular Monitoring: Utilize the LCD display or optional WiFi monitoring app to regularly check system performance and identify any potential issues early.
- Environmental Considerations: While the inverter has an anti-dust kit, installing it in a well-ventilated, cool, and dry location will further enhance its longevity and performance.